Matthias Max Frey

Dr. Matthias Max Frey

orcid

Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 March 2019 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
MFMatthias Max Frey
Matthias Max Frey
MSMahesh Kumar Sha
Mahesh Kumar Sha
FHFrank Hase
Frank Hase
MKMatthäus Kiel
Matthäus Kiel
TBThomas Blumenstock
Thomas Blumenstock
JOJohannes Orphal
Johannes Orphal
In a 3.5-year long study, the long-term performance of a mobile, solar absorption Bruker EM27/SUN spectrometer, used for greenhouse gas observations, is checked with respect to a co-located reference Bruker IFS 125HR spectrometer, which is part of the Total Carbon Column Observing Network (TCCON). We find that the EM27/SUN is stable on timescales of several years; the drift per year between the EM27/SUN and the official TCCON product is 0.02 ppmv for XCO 2 and 0.9 ppbv for XCH 4 , which is within the 1 σ precision of the comparison, 0.6 ppmv for XCO 2 and 4.3 ppbv for XCH 4 . The bias between the two data sets is 3.9 ppmv for XCO 2 and 13.0 ppbv for XCH 4 . In order to avoid sensitivity-dependent artifacts, the EM27/SUN is also compared to a truncated IFS 125HR data set derived from full-resolution TCCON interferograms. The drift is 0.02 ppmv for XCO 2 and 0.2 ppbv for XCH 4 per year, with 1 σ precisions of 0.4 ppmv for XCO 2 and 1.4 ppbv for XCH 4 , respectively. The bias between the two data sets is 0.6 ppmv for XCO 2 and 0.5 ppbv for XCH 4 . With the presented long-term stability, the EM27/SUN qualifies as an useful supplement to the existing TCCON network in remote areas. To achieve consistent performance, such an extension requires careful testing of any spectrometers involved by application of common quality assurance measures. One major aim of the COllaborative Carbon Column Observing Network (COCCON) infrastructure is to provide these services to all EM27/SUN operators. In the framework of COCCON development, the performance of an ensemble of 30 EM27/SUN spectrometers was tested and found to be very uniform, enhanced by the centralized inspection performed at the Karlsruhe Institute of Technology prior to deployment. Taking into account measured instrumental line shape parameters for each spectrometer, the resulting average bias across the ensemble with respect to the reference EM27/SUN used in the long-term study in XCO 2 is 0.20 ppmv, while it is 0.8 ppbv for XCH 4 . The average standard deviation of the ensemble is 0.13 ppmv for XCO 2 and 0.6 ppbv for XCH 4 . In addition to the robust metric based on absolute differences, we calculate the standard deviation among the empirical calibration factors. The resulting 2 σ uncertainty is 0.6 ppmv for XCO 2 and 2.2 ppbv for XCH 4 . As indicated by the executed long-term study on one device presented here, the remaining empirical calibration factor deduced for each individual instrument can be assumed constant over time. Therefore the application of these empirical factors is expected to further improve the EM27/SUN network conformity beyond the scatter among the empirical calibration factors reported above.

31 July 2015 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
FHFrank Hase
Frank Hase
MFMatthias Max Frey
Matthias Max Frey
TBT. Blumenstock
T. Blumenstock
JGJ. Groß
J. Groß
MKMatthäus Kiel
Matthäus Kiel
JOJ. Orphal
J. Orphal
Five portable Bruker EM27/SUN FTIR (Fourier transform infrared) spectrometers have been used for the accurate and precise observation of column-averaged abundances of CO2 and CH4 around the major city Berlin. In the work by Frey et al. (2015), a calibration procedure is developed and applied to the set of spectrometers used for the Berlin campaign. Here, we describe the observational setup of the campaign and aspects of the data analysis, and we present the recorded time series of XCH4 and XCO2. We demonstrate that the CO2 emissions of Berlin can be clearly identified in the observations. A simple dispersion model is applied which indicates a total strength of the Berlin source of about 0.8 t CO2 s−1. In the Supplement of this work, we provide the measured data set and auxiliary data. We hope that the model community will exploit this unique data set for state-of-the art inversion studies of CO2 and CH4 sources in the Berlin area.

31 July 2015 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
MFMatthias Max Frey
Matthias Max Frey
FHF. Hase
F. Hase
TBT. Blumenstock
T. Blumenstock
JGJ. Groß
J. Groß
MKMatthäus Kiel
Matthäus Kiel
JOJ. Orphal
J. Orphal
A comprehensive calibration procedure for mobile, low-resolution, solar-absorption FTIR spectrometers, used for greenhouse gases observations, is developed. These instruments commend themselves for campaign use and deployment at remote sites. The instrumental line shape (ILS) of each spectrometer has been thoroughly characterized by analyzing the shape of H2O signatures in open path spectra. A setup for the external source is suggested and the invariance of derived ILS parameters with regard to chosen path length is demonstrated. The instrumental line shape characteristics of all spectrometers were found to be close to nominal. Side-by-side solar observations before and after a campaign, which involved shipping of all spectrometers to a selected target site and back, are applied for verifying the temporal invariability of instrumental characteristics and for deriving intercalibration factors for XCO2 and XCH4, which take into account residual differences of instrumental characteristics. An excellent level of agreement and stability was found between the different spectrometers: the uncorrected biases in XCO2 and XCH4 are smaller than 0.01 and 0.15 %, respectively, and the drifts are smaller than 0.005 and 0.035 %. As an additional sensitive demonstration of the instrumental performance we show the excellent agreement of ground pressure values obtained from the total column measurements of O2 and barometric records. We find a calibration factor of 0.9700 for the spectroscopic measurements in comparison to the barometric records and a very small scatter between the individual spectrometers (0.02 %). As a final calibration step, using a co-located TCCON (Total Carbon Column Observation Network) spectrometer as a reference, a common scaling factor has been derived for the XCO2 and XCH4 products, which ensures that the records are traceable to the WMO in situ scale.

25 May 2016 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
FHFrank Hase
Frank Hase
MFMatthias Max Frey
Matthias Max Frey
MKMatthäus Kiel
Matthäus Kiel
TBThomas Blumenstock
Thomas Blumenstock
RHRoland Harig
Roland Harig
JOJohannes Orphal
Johannes Orphal
The portable FTIR (Fourier transform infrared) spectrometer EM27/SUN, dedicated to the precise and accurate observation of column-averaged abundances of methane and carbon dioxide, has been equipped with a second detector channel, which allows the detection of additional species, especially carbon monoxide. This allows an improved characterisation of observed carbon dioxide enhancements and makes the extended spectrometer especially suitable as a validation tool of ESA's Sentinel 5 Precursor mission, as it now covers the same spectral region as used by the infrared channel of the TROPOMI (TROPOspheric Monitoring Instrument) sensor. The extension presented here does not rely on a dichroic, but instead a fraction of the solar beam is decoupled near the aperture stop of the spectrometer using a small plane mirror. This approach allows maintaining the camera-controlled solar tracker set-up, which is referenced to the field stop in front of the primary detector. Moreover, the upgrade of existing instruments can be performed without alterating the optical set-up of the primary channel and resulting changes of the instrumental characteristics of the original instrument.

22 April 2022 in Atmospheric Measurement Techniques
Verified
Journal Article
Open access
PDF file
CACarlos Alberti
Carlos Alberti
FHFrank Hase
Frank Hase
MFMatthias Max Frey
Matthias Max Frey
DDDarko Dubravica
Darko Dubravica
TBThomas Blumenstock
Thomas Blumenstock
JOJohannes Orphal
Johannes Orphal
In this study, an extension on the previously reported status of the COllaborative Carbon Column Observing Network's (COCCON) calibration procedures incorporating refined methods is presented. COCCON is a global network of portable Bruker EM27/SUN FTIR spectrometers for deriving column-averaged atmospheric abundances of greenhouse gases. The original laboratory open-path lamp measurements for deriving the instrumental line shape (ILS) of the spectrometer from water vapour lines have been refined and extended to the secondary detector channel incorporated in the EM27/SUN spectrometer for detection of carbon monoxide (CO). The refinements encompass improved spectroscopic line lists for the relevant water lines and a revision of the laboratory pressure measurements used for the analysis of the spectra. The new results are found to be in good agreement with those reported by Frey et al. (2019) and discussed in detail. In addition, a new calibration cell for ILS measurements was designed, constructed and put into service. Spectrometers calibrated since January 2020 were tested using both methods for ILS characterization, open-path (OP) and cell measurements. We demonstrate that both methods can detect the small variations in ILS characteristics between different spectrometers, but the results of the cell method indicate a systematic bias of the OP method. Finally, a revision and extension of the COCCON network instrument-to-instrument calibration factors for XCO2, XCO and XCH4 is presented, incorporating 47 new spectrometers (of 83 in total by now). This calibration is based on the reference EM27/SUN spectrometer operated by the Karlsruhe Institute of Technology (KIT) and spectra collected by the collocated TCCON station Karlsruhe. Variations in the instrumental characteristics of the reference EM27/SUN from 2014 to 2017 were detected, probably arising from realignment and the dual-channel upgrade performed in early 2018. These variations are considered in the evaluation of the instrument-specific calibration factors in order to keep all tabulated calibration results consistent.

10 January 2022 in Atmospheric Chemistry and Physics
Verified
Journal Article
Open access
PDF file
QTQiansi Tu
Qiansi Tu
FHFrank Hase
Frank Hase
MSMatthias Schneider
Matthias Schneider
OGOmaira García
Omaira García
TBThomas Blumenstock
Thomas Blumenstock
CTCarlos Torres
Carlos Torres
The objective of this study is to derive methane (CH4) emissions from three landfills, which are found to be the most significant CH4 sources in the metropolitan area of Madrid in Spain. We derive CH4 emissions from the CH4 enhancements observed by spaceborne and ground-based instruments. We apply satellite-based measurements from the TROPOspheric Monitoring Instrument (TROPOMI) and the Infrared Atmospheric Sounding Interferometer (IASI) together with measurements from the ground-based COllaborative Carbon Column Observing Network (COCCON) instruments. In 2018, a 2-week field campaign for measuring the atmospheric concentrations of greenhouse gases was performed in Madrid in the framework of Monitoring of the Greenhouse Gases Concentrations in Madrid (MEGEI-MAD) project. Five COCCON instruments were deployed at different locations around the Madrid city center, enabling the observation of total column-averaged CH4 mixing ratios (XCH4). Considering the prevalent wind regimes, we calculate the wind-assigned XCH4 anomalies for two opposite wind directions. Pronounced bipolar plumes are found when applying the method to NO2, which implies that our method of wind-assigned anomaly is suitable to estimate enhancements of trace gases at the urban level from satellite-based measurements. For quantifying the CH4 emissions, the wind-assigned plume method is applied to the TROPOMI XCH4 and to the lower tropospheric CH4 / dry-air column ratio (TXCH4) of the combined TROPOMI+IASI product. As CH4 emission strength we estimate 7.4 × 1025 ± 6.4 × 1024 molec. s−1 from the TROPOMI XCH4 data and 7.1 × 1025 ± 1.0 × 1025 molec. s−1 from the TROPOMI+IASI merged TXCH4 data. We use COCCON observations to estimate the local source strength as an independent method. COCCON observations indicate a weaker CH4 emission strength of 3.7 × 1025 molec. s−1 from a local source (the Valdemingómez waste plant) based on observations from a single day. This strength is lower than the one derived from the satellite observations, and it is a plausible result. This is because the analysis of the satellite data refers to a larger area, covering further emission sources in the study region, whereas the signal observed by COCCON is generated by a nearby local source. All emission rates estimated from the different observations are significantly larger than the emission rates provided via the official Spanish Register of Emissions and Pollutant Sources.