Daniel Buchbinder

Prof. Dr. Daniel Buchbinder


Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
Verified
Journal Article
Open access
PDF file
MWMax Wilkat
Max Wilkat
DBDaniel Buchbinder
Daniel Buchbinder
GAGregorio Sanchez Aniceto
Gregorio Sanchez Aniceto
GMGerson Mast
Gerson Mast
Reconstruction of cranio-maxillofacial defects following ablative surgeries requires a comprehensive approach that balances functional restoration with aesthetic outcomes. Advances in computer-aided design and manufacturing (CAD/CAM) technology have revolutionized this field, enabling precise preoperative planning, including 3D modeling, segmentation, and virtual resection planning. These methods allow for the production of patient-specific implants and surgical templates while facilitating the evaluation of treatment outcomes. CAD/CAM technology offers numerous benefits, such as enhanced surgical accuracy, improved aesthetic results, reduced operative times, and the possibility of single-stage resection and reconstruction. However, limitations exist, including high costs, the need for specialized expertise, and dependency on accurate imaging data. This paper provides a surgeon-centric evaluation of the advantages and limitations of CAD/CAM in cranio-maxillofacial reconstruction. The discussion encompasses the technological workflow, clinical applications, and recommendations for optimizing outcomes. Future perspectives highlight ongoing developments, such as integrating non-ionizing imaging techniques and expanding the applicability of virtual and augmented reality. By synthesizing technical advancements and clinical expertise, this review aims to establish practical guidelines for implementing CAD/CAM technology in routine surgical practice.

Verified
Journal Article
Open access
PDF file
THTodd Hanna
Todd Hanna
KBKetan Bansal
Ketan Bansal
RIRobert Radu Ilesan
Robert Radu Ilesan
DBDaniel Buchbinder
Daniel Buchbinder
Background: The current high standards in orthognathic surgery demand surgical solutions that are both ⁠ functionally ⁠ effective and aesthetically pleasing. Our approach offers one for enhanced stability, attractiveness, and nerve protection ⁠ with improved accessibility ⁠ in the majority of orthognathic scenarios ⁠ compared to an inverted L osteotomy. Methods: A case series is presented to illustrate the application and outcomes of HSSO, an optimised approach that combines the advantages of a transoral inverted L osteotomy with specific enhancements and increased versatility, ⁠ with accessibility and exposure similar to a BSSO. Results: HSSO as a completely transoral technique, demonstrate the ability to perform significant counterclockwise rotations of the mandible, eliminating the need for trocars or skin incisions. We experinced high postoperative stability when HSSO was performed in conjunction with a three-piece LeFort 1 osteotomy on a dynamic opposing arch. In comparison to an inverted L approach, we postulated that HSSO offers advantages in stability, due to the increased segmental overlap of the proximal and distal segments of the mandible. This approach is designed to enhance the safety of the inferior alveolar nerve compared to traditional sagittal split methods. Furthermore, HSSO represents an alternative to total joint replacement in select cases of idiopathic condylar resorption and is effective for correcting mandibular asymmetries while maintaining jawline aesthetics. This is achieved through the manipulation of the mandibular angle, ramus height, and inferior border without creating a step deformity in the soft tissue. Conclusions: The outcomes of HSSO highlight its capacity to deliver predictable, functional, and aesthetically pleasing results, offering a viable alternative to more traditional orthognathic techniques.

27 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
CCCarl-Peter Cornelius
Carl-Peter Cornelius
PLParis Georgios Liokatis
Paris Georgios Liokatis
TDTimothy D Doerr
Timothy D Doerr
DMDamir Matic
Damir Matic
SFStefano Fusetti
Stefano Fusetti
DBDaniel Buchbinder
Daniel Buchbinder
Study design: Trends in utilization of MMF types are shifting nowadays from tooth-borne devices over specialized screws to hybrid MMF devices. Hybrid MMF devices come in self-made Erich arch bar modifications and commercial hybrid MMF systems (CHMMFSs). Objective: Survey on available technical/clinical data. Hypothetically the risk of tooth root damage by transalveolar screws is diminished by a targeting function of the screw holes/slots. Methods: Literature review; graphic displays to disclose parallels and dissimilarities of design and functionality with an in-depth look at the targeting properties. Results: Self-made hybrid arch bars have limitations to meet low-risk interradicular screw insertion sites. Technical/clinical information on CHMMFSs is unevenly distributed in favor of the SMARTLock System: positive outcome variables are increased speed of application/removal, possibility to eliminate wiring and stick injuries, screw fixation with standoff of the embodiment along the attached gingiva. Inferred from the SMARTLock System all four CHMMFs possess potential to effectively prevent tooth root injuries but are subject to their design features and targeting with the screw receiving holes. The height profile and geometry shape of a CHMMFS may restrict 3-dimensional spatial orientation and reach during placement. To bridge between interradicular spaces and tooth equators, where hooks or cleats for intermaxillary cerclages should be ideally positioned under biomechanical aspects, can be problematic. The movability of their screw receiving holes according to all six degrees of freedom, differs. Conclusion: CHMMFSs allow simple immobilization of facial fractures involving dental occlusion. The performance to avoid tooth root damage is a matter of design subtleties.

Verified
Journal Article
Open access
PDF file
CCCarl-Peter Cornelius
Carl-Peter Cornelius
PLParis Georgios Liokatis
Paris Georgios Liokatis
TDTimothy D Doerr
Timothy D Doerr
DMDamir Matic
Damir Matic
SFStefano Fusetti
Stefano Fusetti
DBDaniel Buchbinder
Daniel Buchbinder
Study design: Trends in the utilization of Mandibulo-Maxillary Fixation (MMF) are shifting nowadays from tooth-borne devices over specialized screws to hybrid MMF devices. Hybrid MMF devices come in self-made Erich arch bar modifications and commercial hybrid MMF systems (CHMMFSs). Objective: We survey the available technical/clinical data. Hypothetically, the risk of tooth root damage by transalveolar screws is diminished by a targeting function of the screw holes/slots. Methods: We utilize a literature review and graphic displays to disclose parallels and dissimilarities in design and functionality with an in-depth look at the targeting properties. Results: Self-made hybrid arch bars have limitations to meet low-risk interradicular screw insertion sites. Technical/clinical information on CHMMFSs is unevenly distributed in favor of the SMARTLock System: positive outcome variables are increased speed of application/removal, the possibility to eliminate wiring and stick injuries and screw fixation with standoff of the embodiment along the attached gingiva. Inferred from the SMARTLock System, all four CHMMFs possess potential to effectively prevent tooth root injuries but are subject to their design features and targeting with the screw-receiving holes. The height profile and geometry shape of a CHMMFS may restrict three-dimensional spatial orientation and reach during placement. To bridge between interradicular spaces and tooth equators, where hooks or tie-up-cleats for intermaxillary cerclages should be ideally positioned under biomechanical aspects, can be problematic. The movability of their screw-receiving holes according to all six degrees of freedom differs. Conclusion: CHMMFSs allow simple immobilization of facial fractures involving dental occlusion. The performance in avoiding tooth root damage is a matter of design subtleties.

Verified
Journal Article
Open access
PDF file
CCCarl-Peter Cornelius
Carl-Peter Cornelius
PLParis Georgios Liokatis
Paris Georgios Liokatis
TDTimothy D Doerr
Timothy D Doerr
DMDamir Matic
Damir Matic
SFStefano Fusetti
Stefano Fusetti
DBDaniel Buchbinder
Daniel Buchbinder
Study design: The advent of the Matrix WaveTM System (Depuy-Synthes)—a bone-anchored Mandibulo-Maxillary Fixation (MMF) System—merits closer consideration because of its peculiarities. Objective: This study alludes to two preliminary stages in the evolution of the Matrix WaveTM MMF System and details its technical and functional features. Results: The Matrix WaveTM System (MWS) is characterized by a smoothed square-shaped Titanium rod profile with a flexible undulating geometry distinct from the flat plate framework in Erich arch bars. Single MWS segments are Omega-shaped and carry a tie-up cleat for interarch linkage to the opposite jaw. The ends at the throughs of each MWS segment are equipped with threaded screw holes to receive locking screws for attachment to underlying mandibular or maxillary bone. An MWS can be partitioned into segments of various length from single Omega-shaped elements over incremental chains of interconnected units up to a horseshoe-shaped bracing of the dental arches. The sinus wave design of each segment allows for stretch, compression and torque movements. So, the entire MWS device can conform to distinctive spatial anatomic relationships. Displaced fragments can be reduced by in-situ-bending of the screw-fixated MWS/Omega segments to obtain accurate realignment of the jaw fragments for the best possible occlusion. Conclusion: The Matrix WaveTM MMF System is an easy-to-apply modular MMF system that can be assembled according to individual demands. Its versatility allows to address most facial fracture scenarios in adults. The option of “omnidirectional” in-situ-bending provides a distinctive feature not found in alternate MMF solutions.

28 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
CCCarl-Peter Cornelius
Carl-Peter Cornelius
PLParis Georgios Liokatis
Paris Georgios Liokatis
TDTimothy D Doerr
Timothy D Doerr
DMDamir Matic
Damir Matic
SFStefano Fusetti
Stefano Fusetti
DBDaniel Buchbinder
Daniel Buchbinder
Study design: The advent of Matrix WaveTM System (Depuy-Synthes) - a bone anchored Mandibulo-Maxillary Fixation (MMF) system merits closer consideration because of its peculiarities. Objective: This article alludes to two preliminary stages in the evolution of the Matrix WaveTM MMF System and details its technical and functional features. Results: The Matrix WaveTM System (MWS) is characterized by a smoothed square shaped Titanium rod profile with a flexible undulating geometry unique from the flat plate framework in Erich arch bars. Single MWS segments are Omega-shaped and carry a tie-up-cleat for interarch linkage to the opposite jaw. The ends at the throughs of each MWS segment are equipped with threaded screw holes to receive locking screws for attachment to underlying mandibular or maxillary bone. A MWS can be partitioned into segments of various length from single Omega-shaped elements over incremental chains of interconnected units up to a horseshoe-shaped bracing of the dental arches. The sinus wave design of each segment allows for stretch, compression and torque movements. So the entire MWS device can conform to distinctive spatial anatomic relationships. Displaced fragments can be reduced by in-situ-bending of the screw fixated MWS/Omega segments to obtain accurate realignment of the jaw fragments for the best possible occlusion. Conclusion: The Matrix WaveTM MMF System is an easy to apply modular MMF system, that can be assembled according to individual demands. Its versatility allows to address most facial fracture scenarios in adults. The option of an “omnidirectional” in-situ-bending provides a distinctive feature not found in alternate MMF solutions.