The ventilation of buildings is crucial to ensure indoor health, especially when demanding physical activities are carried out indoors, and the pandemic has highlighted the need to develop new management methods to ensure adequate ventilation. In Spain, there are no specific ventilation regulations to prevent the spread of pathogens such as the coronavirus. Therefore, it is necessary to have a theoretical tool for calculating occupancy to maintain sports facilities in optimal safety conditions. The proposed theoretical method is based on the analysis of mathematical expressions from European standardisation documents and uses the concentration of CO2 as a bioeffluent. It is also based on the concept of background and critical concentration, which allows its application to be extrapolated to future crises caused by pathogens. This study presents a unique and novel dataset for sports centres. For this purpose, the calculation methods were applied to the data set provided by Mostoles City Council, Spain, during the pandemic years with the highest incidence of COVID-19, when the government introduced the assimilation of COVID-19 sick leave to occupational accidents. The data on this type of sick leave provided by the City Council correspond to the period between March 2020 and February 2022. Similarly, the data on the average use of sports facilities by activity, provided by the Sports Department, correspond to the years 2020 and 2021. In this way, it was possible to verify the effectiveness in preventing the spread of any type of coronavirus. In conclusion, the implementation of a theoretical occupancy calculation method based on the concentration of carbon dioxide as a bioeffluent can be an effective tool for the management of future crises caused by pathogens or hazardous chemicals in the air, and demonstrated its effectiveness in sports centres such as gyms, sports fields, and indoor swimming pools during the COVID-19 pandemic.
This paper proposes a novel model to determine occupancy density for outdoor events to prevent infectious disease transmission caused by the impossibility of proper dilution of human effluents in the atmosphere. It uses standardization processes to calculate natural ventilation air renewal and establishes theoretical occupancy based on activity and exhaled air percentage, aiming for indoor air quality comparable to the IDA2 standards. The study focuses on mass events in Mostoles (Spain), analyzing street activities and bullring events. It found that above a certain height in the open air, infection risk is low, eliminating capacity limitations. The resulting mathematical expressions can be adapted to different pathogens, ensuring the quality of indoor air conditions through capacity control. The process determines the ventilation required based on physical activity, considering both unrestricted and restricted situations. The relationship between required and available ventilation prevents disease transmission. The method’s effectiveness is demonstrated through comparisons between estimates and environmental measurements during Mostoles events. The maximum outdoor occupancy at ground level to achieve air quality comparable to the IDA2 standards is determined to be 2.36 persons/m2, while to prevent the transmission of SARS-CoV-2 it is determined to be 1.98 persons/m2. In addition, transmission will not occur during mass gatherings in locations over five meters above ground level. In conclusion, this model provides an adaptable tool to prevent the spread of infectious diseases at outdoor events by ensuring adequate air quality through occupancy control.
This research presents a scientifically grounded model designed to enhance the safety protocols for firefighting teams during fire intervention scenarios. The model estimates the maximum allowable exposure duration based on ambient temperature and radiant heat, employing data captured by thermal imaging cameras, which provide real-time measurements of infrared radiation emitted by fire-affected zones. Utilising the Stefan–Boltzmann law to quantify radiative heat transfer and Probit vulnerability analysis to assess thermal risk, critical temperature thresholds and corresponding exposure durations were determined. The results indicate that the maximum permissible ambient temperature for firefighting interventions is 263 °C, with a safe exposure duration of 26 s under these thermal conditions. This approach underscores the significance of ambient temperature as a pivotal parameter in risk assessment and intervention strategy development. Furthermore, the model’s applicability extends to other high-risk environments, including industrial operations, providing a robust and versatile framework for safety management. These findings contribute to advancing evidence-based protocols that mitigate injury risks, safeguard firefighting personnel, and optimise operational decision-making during emergencies.
This paper evaluates the effectiveness of natural ventilation as a health and safety strategy in municipal buildings, focusing on its capacity to ensure indoor air quality and limit airborne disease transmission. Natural ventilation can be incorporated into building design as the primary mechanism for achieving the required indoor air quality, equipping buildings with operable windows based on their intended occupancy. Using 11 public buildings in Mostoles, Spain, as case studies, the research applies a quantitative methodology based on carbon dioxide concentration to estimate ventilation rates and theoretical occupancy thresholds. The findings reveal that cross ventilation is the only natural method capable of meeting air renewal rates recommended by health authorities, particularly the IDA2 air quality standard and three to five air changes per hour suggested to reduce disease spread. However, 53% of the assessed spaces lacked cross ventilation capacity, underscoring the need to integrate natural and mechanical systems. The study proposes a replicable model to assess and adapt indoor occupancy based on real ventilation capacity, offering a practical tool for decision-making in public health, energy efficiency, and architectural design. Ultimately, the research supports the strategic use of natural ventilation as a low-cost, scalable intervention to enhance environmental quality in public facilities.
The rising cost of traditional energy sources is forcing us to seek alternatives that enable energy self-sufficiency. At the Madrid Zoo Aquarium (Spain), the production of biomethane through the anaerobic digestion of organic waste is being considered, improving environmental management and achieving a competitive advantage in the energy management process. This opportunity also carries with it the possibility of explosions, fires or polluting environments, which requires the establishment of preventive measures to minimize these risks. To respond to this type of contingency, this study develops both empirical equation and charts that allow the establishment of dangerous distances that must be considered due to the presence of flammable gases escaping into the atmosphere and the duration of the danger, taking into account the influence of environmental conditions and dilution. Different risk situations are considered, both during the operation of the facility and during the cleaning and maintenance of tanks and equipment, as well as in the management of waste generated at the end of treatment.
In architecture and construction, it is common to use acrylic products with a high flammable content, from lacquers to improve the curing of concrete and mortar to resins that offer protection, sealing, flexibility and elasticity properties. The drying process of the treated surface involves the formation of volatile organic compound (VOC) vapours. To prevent these from degenerating into a potentially dangerous flammable atmosphere, a procedure is presented that establishes the maximum application yield for solvent-based products, providing equations that relate the maximum application surface area and minimum drying time to the air velocity available in the work area. The results are provided for both indoor and outdoor applications. A maximum application speed is established to prevent the generation of areas classified as fire or explosion hazards: 1.5 m²/h indoors and 1 m²/h outdoors. When this is carried out at an ambient temperature of 20°C, and above 40°C, it is not possible to apply varnishes without generating a flammable atmosphere.