Janina M Patsch

Prof. Dr. Janina M Patsch


Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2012 in Journal of Bone and Mineral Research
Verified
Journal Article
Open access
PDF file
JPJanina M Patsch
Janina M Patsch
ABAndrew J Burghardt
Andrew J Burghardt
SYSamuel P Yap
Samuel P Yap
TBThomas Baum
Thomas Baum
ASAnn V Schwartz
Ann V Schwartz
TLThomas M Link
Thomas M Link
The primary goal of this study was to assess peripheral bone microarchitecture and strength in postmenopausal women with type 2 diabetes with fragility fractures (DMFx) and to compare them with postmenopausal women with type 2 diabetics without fractures (DM). Secondary goals were to assess differences in nondiabetic postmenopausal women with fragility fractures (Fx) and nondiabetic postmenopausal women without fragility fractures (Co), and in DM and Co women. Eighty women (mean age 61.3 ± 5.7 years) were recruited into these four groups (DMFx, DM, Fx, and Co; n = 20 per group). Participants underwent dual‐energy X‐ray absorptiometry (DXA) and high‐resolution peripheral quantitative computed tomography (HR‐pQCT) of the ultradistal and distal radius and tibia. In the HR‐pQCT images volumetric bone mineral density and cortical and trabecular structure measures, including cortical porosity, were calculated. Bone strength was estimated using micro–finite element analysis (µFEA). Differential strength estimates were obtained with and without open cortical pores. At the ultradistal and distal tibia, DMFx had greater intracortical pore volume (+52.6%, p = 0.009; +95.4%, p = 0.020), relative porosity (+58.1%, p = 0.005; +87.9%, p = 0.011) and endocortical bone surface (+10.9%, p = 0.031; +11.5%, p = 0.019) than DM. At the distal radius DMFx had 4.7‐fold greater relative porosity (p < 0.0001) than DM. At the ultradistal radius, intracortical pore volume was significantly higher in DMFx than DM (+67.8%, p = 0.018). DMFx also displayed larger trabecular heterogeneity (ultradistal radius: +36.8%, p = 0.035), and lower total and cortical BMD (ultradistal tibia: −12.6%, p = 0.031; −6.8%, p = 0.011) than DM. DMFx exhibited significantly higher pore‐related deficits in stiffness, failure load, and cortical load fraction at the ultradistal and distal tibia, and the distal radius than DM. Comparing nondiabetic Fx and Co, we only found a nonsignificant trend with increase in pore volume (+38.9%, p = 0.060) at the ultradistal radius. The results of our study suggest that severe deficits in cortical bone quality are responsible for fragility fractures in postmenopausal diabetic women. © 2013 American Society for Bone and Mineral Research

4 April 2013 in Journal of Bone and Mineral Research
Verified
Journal Article
Open access
PDF file
JPJanina M Patsch
Janina M Patsch
XLXiaojuan Li
Xiaojuan Li
TBThomas Baum
Thomas Baum
SYSamuel P Yap
Samuel P Yap
DKDimitrios Karampinos
Dimitrios Karampinos
TLThomas M Link
Thomas M Link
The goal of this magnetic resonance (MR) imaging study was to quantify vertebral bone marrow fat content and composition in diabetic and nondiabetic postmenopausal women with fragility fractures and to compare them with nonfracture controls with and without type 2 diabetes mellitus. Sixty‐nine postmenopausal women (mean age 63 ± 5 years) were recruited. Thirty‐six patients (47.8%) had spinal and/or peripheral fragility fractures. Seventeen fracture patients were diabetic. Thirty‐three women (52.2%) were nonfracture controls. Sixteen women were diabetic nonfracture controls. To quantify vertebral bone marrow fat content and composition, patients underwent MR spectroscopy (MRS) of the lumbar spine at 3 Tesla. Bone mineral density (BMD) was determined by dual‐energy X‐ray absorptiometry (DXA) of the hip and lumbar spine (LS) and quantitative computed tomography (QCT) of the LS. To evaluate associations of vertebral marrow fat content and composition with spinal and/or peripheral fragility fractures and diabetes, we used linear regression models adjusted for age, race, and spine volumetric bone mineral density (vBMD) by QCT. At the LS, nondiabetic and diabetic fracture patients had lower vBMD than controls and diabetics without fractures (p = 0.018; p = 0.005). However, areal bone mineral density (aBMD) by DXA did not differ between fracture and nonfracture patients. After adjustment for age, race, and spinal vBMD, the prevalence of fragility fractures was associated with −1.7% lower unsaturation levels (confidence interval [CI] −2.8% to −0.5%, p = 0.005) and +2.9% higher saturation levels (CI 0.5% to 5.3%, p = 0.017). Diabetes was associated with −1.3% (CI –2.3% to −0.2%, p = 0.018) lower unsaturation and +3.3% (CI 1.1% to 5.4%, p = 0.004) higher saturation levels. Diabetics with fractures had the lowest marrow unsaturation and highest saturation. There were no associations of marrow fat content with diabetes or fracture. Our results suggest that altered bone marrow fat composition is linked with fragility fractures and diabetes. MRS of spinal bone marrow fat may therefore serve as a novel tool for BMD‐independent fracture risk assessment.

1 February 2011 in Metabolism
Verified
Journal Article
Closed access
JPJanina M Patsch
Janina M Patsch
FKFlorian W. Kiefer
Florian W. Kiefer
PVPeter Varga
Peter Varga
PPPamela Pail
Pamela Pail
MRMartina Rauner
Martina Rauner
PPPeter Pietschmann
Peter Pietschmann

25 May 2011 in Nephrology Dialysis Transplantation
Verified
Journal Article
Closed access
DCDaniel Cejka
Daniel Cejka
AJA. Jager-Lansky
A. Jager-Lansky
HKH. Kieweg
H. Kieweg
MWMichael Weber
Michael Weber
CBC. Bieglmayer
C. Bieglmayer
MHM. Haas
M. Haas
Sclerostin is a soluble inhibitor of osteoblast function. Sclerostin is downregulated by the parathyroid hormone (PTH). Here, it was investigated whether sclerostin levels are influenced by intact (i) PTH and whether sclerostin is associated with bone turnover, microarchitecture and mass in dialysis patients. Seventy-six haemodialysis patients and 45 healthy controls were included in this cross-sectional study. Sclerostin, Dickkopf-1 (DKK-1), intact parathyroid hormone (iPTH), vitamin D and markers of bone turnover were analysed. A subset of 37 dialysis patients had measurements of bone mineral density (BMD) using dual-energy X-ray absorptiometry and bone microarchitecture using high-resolution peripheral quantitative computed tomography. Dialysis patients had significantly higher sclerostin levels than controls (1257 pg/mL versus 415 pg/mL, P < 0.001). Significant correlations were found between sclerostin and gender (R = 0.41), iPTH (R = -0.28), 25-hydroxy-cholecalciferol (R = 0.27) and calcium (R = 0.25). Gender and iPTH remained significantly associated with sclerostin in a multivariate analysis. Sclerostin serum levels were positively associated with BMD at the lumbar spine (R = 0.46), femoral neck (R = 0.36) and distal radius (R = 0.42) and correlated positively mainly with trabecular structures such as trabecular density and number at the radius and tibia in dialysis patients. DKK-1 was related neither to bone measures nor to serologic parameters. Considering that sclerostin is an inhibitor of bone formation, the observed positive correlations of serum sclerostin with BMD and bone volume were unexpected. Whether its increase in dialysis patients has direct pathogenetic relevance or is only a secondary phenomenon remains to be seen.

27 June 2016 in Journal of Bone and Mineral Research
Verified
Journal Article
Open access
PDF file
UHUrsula Heilmeier
Ursula Heilmeier
MHMatthias Hackl
Matthias Hackl
SSSusanna Skalicky
Susanna Skalicky
SWSylvia Weilner
Sylvia Weilner
FSFabian Schroeder
Fabian Schroeder
TLThomas M Link
Thomas M Link
Standard DXA measurements, including Fracture Risk Assessment Tool (FRAX) scores, have shown limitations in assessing fracture risk in Type 2 Diabetes (T2D), underscoring the need for novel biomarkers and suggesting that other pathomechanisms may drive diabetic bone fragility. MicroRNAs (miRNAs) are secreted into the circulation from cells of various tissues proportional to local disease severity and were recently found to be crucial to bone homeostasis and T2D. Here, we studied, if and which circulating miRNAs or combinations of miRNAs can discriminate best fracture status in a well‐characterized study of diabetic bone disease and postmenopausal osteoporosis (n = 80 postmenopausal women). We then tested the most discriminative and most frequent miRNAs in vitro. Using miRNA‐qPCR‐arrays, we showed that 48 miRNAs can differentiate fracture status in T2D women and that several combinations of four miRNAs can discriminate diabetes‐related fractures with high specificity and sensitivity (area under the receiver‐operating characteristic curve values [AUCs], 0.92 to 0.96; 95% CI, 0.88 to 0.98). For the osteoporotic study arm, 23 miRNAs were fracture‐indicative and potential combinations of four miRNAs showed AUCs from 0.97 to 1.00 (95% CI, 0.93 to 1.00). Because a role in bone homeostasis for those miRNAs that were most discriminative and most present among all miRNA combinations had not been described, we performed in vitro functional studies in human adipose tissue–derived mesenchymal stem cells to investigate the effect of miR‐550a‐5p, miR‐188‐3p, and miR‐382‐3p on osteogenesis, adipogenesis, and cell proliferation. We found that miR‐382‐3p significantly enhanced osteogenic differentiation (p < 0.001), whereas miR‐550a‐5p inhibited this process (p < 0.001). Both miRNAs, miR‐382‐3p and miR‐550a‐5p, impaired adipogenic differentiation, whereas miR‐188‐3p did not exert an effect on adipogenesis. None of the miRNAs affected significantly cell proliferation. Our data suggest for the first time that miRNAs are linked to fragility fractures in T2D postmenopausal women and should be further investigated for their diagnostic potential and their detailed function in diabetic bone. © 2016 American Society for Bone and Mineral Research.

16 October 2012 in Journal of Bone and Mineral Research
Verified
Journal Article
Open access
PDF file
ABAndrew J Burghardt
Andrew J Burghardt
JPJean-Baptiste Pialat
Jean-Baptiste Pialat
GKGalateia J Kazakia
Galateia J Kazakia
SBStephanie Boutroy
Stephanie Boutroy
KEKlaus Engelke
Klaus Engelke
SMSharmila Majumdar
Sharmila Majumdar
High‐resolution peripheral quantitative computed tomography (HR‐pQCT) has recently been introduced as a clinical research tool for in vivo assessment of bone quality. The utility of this technology to address important skeletal health questions requires translation to standardized multicenter data pools. Our goal was to evaluate the feasibility of pooling data in multicenter HR‐pQCT imaging trials. Reproducibility imaging experiments were performed using structure and composition‐realistic phantoms constructed from cadaveric radii. Single‐center precision was determined by repeat scanning over short‐term (<72 hours), intermediate‐term (3–5 months), and long‐term intervals (28 months). Multicenter precision was determined by imaging the phantoms at nine different HR‐pQCT centers. Least significant change (LSC) and root mean squared coefficient of variation (RMSCV) for each interval and across centers was calculated for bone density, geometry, microstructure, and biomechanical parameters. Single‐center short‐term RMSCVs were <1% for all parameters except cortical thickness (Ct.Th) (1.1%), spatial variability in cortical thickness (Ct.Th.SD) (2.6%), standard deviation of trabecular separation (Tb.Sp.SD) (1.8%), and porosity measures (6% to 8%). Intermediate‐term RMSCVs were generally not statistically different from short‐term values. Long‐term variability was significantly greater for all density measures (0.7% to 2.0%; p < 0.05 versus short‐term) and several structure measures: cortical thickness (Ct.Th) (3.4%; p < 0.01 versus short‐term), cortical porosity (Ct.Po) (15.4%; p < 0.01 versus short‐term), and trabecular thickness (Tb.Th) (2.2%; p < 0.01 versus short‐term). Multicenter RMSCVs were also significantly higher than short‐term values: 2% to 4% for density and micro–finite element analysis (µFE) measures (p < 0.0001), 2.6% to 5.3% for morphometric measures (p < 0.001), whereas Ct.Po was 16.2% (p < 0.001). In the absence of subject motion, multicenter precision errors for HR‐pQCT parameters were generally less than 5%. Phantom‐based multicenter precision was comparable to previously reported in in vivo single‐center precision errors, although this was approximately two to five times worse than ex vivo short‐term precision. The data generated from this study will contribute to the future design and validation of standardized procedures that are broadly translatable to multicenter study designs. © 2013 American Society for Bone and Mineral Research.