Youssouf Brahami

Dr. Youssouf Brahami

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2025 in Energies
Verified
Journal Article
Open access
PDF file
MAMeysam Beheshti Asl
Meysam Beheshti Asl
Issouf FofanaIssouf Fofana
Issouf Fofana
Meghnefi FethiMeghnefi Fethi
Meghnefi Fethi
Youssouf BrahamiYoussouf Brahami
Youssouf Brahami
JSJoão Pedro da Costa Souza
João Pedro da Costa Souza
Frequency Response Analysis (FRA) is a proven method for detecting mechanical faults in transformers, such as winding deformations and short circuits. However, traditional FRA interpretation relies heavily on visual and subjective comparison of frequency response curves, which can introduce human bias and lead to inconsistent results. Integrating Machine Learning (ML) with FRA can significantly enhance fault diagnosis by automatically identifying complex patterns within the data that are difficult to detect using through human analysis. This integration can automate diagnostics, enhance accuracy, improve predictive maintenance, reduce reliance on expert interpretation and curtail operational costs. This paper reviews the application of FRA and ML alongside complementary techniques for transformer winding health assessment.

10 March 2025 in IEEE Access
Verified
Journal Article
Open access
GGGhada Gmati
Ghada Gmati
Issouf FofanaIssouf Fofana
Issouf Fofana
Patrick PicherPatrick Picher
Patrick Picher
Meghnefi FethiMeghnefi Fethi
Meghnefi Fethi
OAOscar H Arroyo-Fernandez
Oscar H Arroyo-Fernandez
YKYapi Marie Lucia Kouba
Yapi Marie Lucia Kouba
The bubbling inception temperature (BIT) of insulating materials used in transformers is critical for their performance and lifespan. This study, which represents the first part of a two-part series, provides a comparative analysis of the BIT for kraft paper, thermally upgraded kraft paper (TUK), and aramid paper impregnated with mineral oil. A customized experimental setup was used to measure the BIT under controlled laboratory conditions. The uniqueness of the setup lies in its precise control of dynamic load conditions via an autotransformer, real-time bubble detection, continuous moisture in oil and temperature monitoring using sensors, the use of capacitive measurement to assess moisture content in paper, and the flexibility to test different oils and insulation materials. This combination enables accurate analysis of bubble formation in oil-paper insulation systems under realistic conditions. Results show that TUK paper has the highest BIT, followed by kraft and aramid papers. Additionally, the study introduces new empirical equations for predicting BIT based on water content for each paper type, notably filling a gap for aramid paper. These equations are valuable for practical engineering applications. The research underscores the importance of moisture control in determining BIT and suggests future studies focused on standardizing methodologies and exploring different dielectric fluids. The findings contribute to improving the design, maintenance, and reliability of transformer insulation systems. Part 2 of this study will further explore the long-term effects of thermal aging and alternative dielectric fluids on BIT.

9 July 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Youssouf BrahamiYoussouf Brahami
Youssouf Brahami
SOSAMSON OKIKIOLA OPARANTI
SAMSON OKIKIOLA OPARANTI
Issouf FofanaIssouf Fofana
Issouf Fofana
Meghnefi FethiMeghnefi Fethi
Meghnefi Fethi
Power transformer insulation systems, composed of liquid and solid insulators, are continuously exposed to thermal and electrical stresses that degrade their performance over time and may lead to premature failure. Since these stresses are unavoidable during operation, selecting effective insulating materials is critical for long-term reliability. In this study, Kraft insulation paper was used as the solid insulator and impregnated with three different liquids: mineral oil and two natural esters (NE1204 and NE1215), to evaluate their stability under simultaneous thermal and electrical stress. The degradation behavior of the oil-impregnated papers was assessed using frequency-domain dielectric spectroscopy (FDS) and Fourier-transform infrared spectroscopy (FTIR), enabling early fault detection. Comparative analyses were conducted to evaluate the withstand capability of each liquid type during operation. Results revealed strong correlations between FTIR indicators (e.g., oxidation and hydroxyl group loss) and dielectric parameters (permittivity and loss factor), confirming the effectiveness of this combined diagnostic approach. Post-aging breakdown analysis showed that natural esters, particularly NE1215, offered superior preservation of insulation integrity compared to mineral oil. Differences between the two esters also highlight the role of chemical composition in insulation performance. This study reinforces the potential of natural esters as viable, eco-friendly alternatives in thermally and electrically stressed applications.

8 February 2025 in Energies
Verified
Journal Article
Open access
PDF file
Youssouf BrahamiYoussouf Brahami
Youssouf Brahami
ABAmidou Betie
Amidou Betie
Meghnefi FethiMeghnefi Fethi
Meghnefi Fethi
Issouf FofanaIssouf Fofana
Issouf Fofana
Zié YEOZié YEO
Zié YEO
The presence of moisture in the insulation of power transformers accelerates the degradation of both paper and oil, thereby increasing the risk of unexpected failures. Due to the hygroscopic nature of cellulose, the insulation can retain up to 8% moisture after the transformer manufacturing process. Reducing this moisture content is crucial in extending the operational lifespan of transformers. The drying cycle of paper insulation is a critical step in power transformer manufacturing, directly influencing the insulation’s longevity and overall performance. This paper introduces a nomogram that combines degradation and drying models, enabling the precise optimization of the drying process based on various parameters such as the temperature, paper mass, and extraction rate. The results of this study demonstrate that for a given extraction rate threshold, the required drying time can be determined based on the mass of paper to be dried, the drying temperature, and the degree of paper degradation (degree of polymerization). These predictive tools are essential for engineers and researchers aiming to enhance transformer reliability.

29 August 2025 in Energies
Verified
Journal Article
Open access
PDF file
GGGhada Gmati
Ghada Gmati
Issouf FofanaIssouf Fofana
Issouf Fofana
Patrick PicherPatrick Picher
Patrick Picher
OAOscar H Arroyo-Fernandez
Oscar H Arroyo-Fernandez
DRDjamal Rebaine
Djamal Rebaine
KYKouba Marie Lucia Yapi
Kouba Marie Lucia Yapi
Bubbling Inception Temperature (BIT) is a critical metric that indicates the temperature at which gas bubbles form due to cellulose decomposition in a paper–oil insulation system. It serves as a key indicator of the thermal stability of transformer insulation, offering valuable insights into its performance under elevated temperatures. Building on findings from a companion study that examined the BIT of Kraft paper (KP), thermally upgraded Kraft paper (TUK), and aramid paper in mineral oil, this research expands the analysis to assess the impact of moisture, aging, and alternative dielectric fluids. Using the same customized experimental setup featuring precise dynamic load control, real-time bubble detection, and continuous monitoring of moisture and temperature, this study evaluates BIT across four distinct oil–paper aging stages: new (0 h) and 2 weeks, 4 weeks, and 6 weeks of accelerated thermal aging. This approach enables a comparative analysis of BIT in various paper–oil systems, focusing on both mineral oil and synthetic esters, as well as the influence of different moisture levels in the paper insulation. The results show that BIT decreases with aging, indicating reduced thermal stability. Furthermore, KP impregnated with synthetic ester exhibits a higher BIT than when impregnated with mineral oil, suggesting that synthetic esters may offer better resistance to bubble formation under thermal stress. Based on these results, empirical BIT models were developed as a function of degree of polymerization (DP) and water content in paper (WCP). This study further demonstrates how these models can be applied to quantify safety margins under emergency overloading conditions, providing a practical tool for operational decision-making in transformer thermal risk management.

2 May 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Youssouf BrahamiYoussouf Brahami
Youssouf Brahami
Issouf FofanaIssouf Fofana
Issouf Fofana
SOSAMSON OKIKIOLA OPARANTI
SAMSON OKIKIOLA OPARANTI
Meghnefi FethiMeghnefi Fethi
Meghnefi Fethi
KYKouba Marie Lucia Yapi
Kouba Marie Lucia Yapi
Nanofluids have emerged as promising candidates for enhancing the dielectric and thermal performance of insulating liquids used in power transformers. While numerous studies report significant improvements in breakdown voltage (up to +10–40%) and thermal conductivity, the underlying mechanisms remain only partially understood and often contradictory, particularly with respect to long-term stability and ageing behavior. This paper presents a comprehensive and critical review of nanofluids applied to transformer insulation, adopting a system-level approach focused on the oil–paper insulation system. The analysis reveals that the reported performance strongly depends on key parameters such as nanoparticle concentration, dispersion quality, and experimental conditions, leading to significant inter-study variability. Dielectric improvements are shown to be maximized within narrow concentration ranges and may deteriorate due to nanoparticle aggregation, while thermal enhancements are often accompanied by increased viscosity, resulting in a thermo-hydraulic trade-off. Furthermore, this review highlights major contradictions in the literature, including the paradoxical relationship between electrical conductivity and dielectric strength, as well as the unclear impact of nanofluids on cellulose ageing. The findings demonstrate that performance observed at the fluid level cannot be directly extrapolated to real transformer conditions without considering the complex interactions between nanoparticles, oil, cellulose, and moisture. To address these limitations, a conceptual framework termed Nano-Modified Composite Insulation (NMCI) is proposed. This model provides a unified description of multiphase interactions and offers a basis for a more realistic evaluation of nanofluids under operational conditions. This work emphasizes the need for standardized experimental methodologies and long-term studies and provides clear research directions toward the development of reliable and industrially applicable nanofluid-based insulation systems.