Introduction This study evaluated novel automatic dual rotational Risley prisms (ADRRPs) as a vergence exercise tool for patients with myopia to improve accommodative lag and accommodative facility. Methods Participants with myopia aged 20–24 years were recruited. After vergence exercises with prisms (treatment group) or plano lenses (control group) using ADRRPs for 10 min, measurements were taken using an open-field autorefractor (Grand Seiko WAM-5500) at viewing distances of 0.4 m and 6.0 m. We measured accommodative facility using a ± 2.00 D accommodative flipper. Results A total of 56 participants (treatment group, 39; control group, 17) performed vergence exercises using ADRRPs. Participants in the treatment group showed improvements in accommodative lag at a 0.4 m viewing distance, with measurements of 0.57 D (right eye; OD) and 0.53 D (left eye; OS) and 0.21 D (OD) and 0.27 D (OS) before and after the exercises, respectively (p < 0.001). Over-refractions using an open-field autorefractor with spherical equivalent contact lenses at a 6.0 m viewing distance were − 0.01 ± 0.30 D (OD) and 0.03 ± 0.34 D (OS) and 0.15 ± 0.32 D (OD) and 0.19 ± 0.28 D (OS) before and after the exercises, respectively (difference + 0.16 D; p < 0.001). Accommodative facility values before and after exercises were 14.88 ± 3.36 and 15.59 ± 3.60 cpm, respectively (p < 0.01). No significant differences in accommodative lag, relaxation, and accommodative facility before and after exercise were observed in the control group. Conclusions Using ADRRPs in vergence exercises can improve accommodative lag, accommodative facility, and accommodative relaxation in adults with myopia. Further research to evaluate persistent and long-term effects is needed.
Introduction This study investigated the effects of automatic dual rotational Risley prisms (ADRRPs), a mobile phone application-operated device, on vergence abilities in young adults. Methods Fifty-six participants aged 20–24 performed vergence exercises. The test group used prisms with power changes from 30Δ base-out to 10Δ base-in, while the control group used plano lenses for 10 min. Ophthalmic examinations included lateral heterophoria, near point of convergence (NPC), vergence facility (VF), negative fusional vergence (NFV), and positive fusional vergence (PFV), all measured before and after the vergence exercises. Pre- and post-test results were analyzed using a paired sample t test. Additionally, three cases with convergence insufficiency (CI) performed similar exercises for 12 weeks. Results Participants were divided into the test group (n = 39; age 21.82 ± 1.10 years) and control group (n = 17; age 20.53 ± 0.51 years). In the test group, NPC improved from 6.11 ± 2.52 cm to 5.77 ± 2.30 cm (p = 0.023). VF increased from 13.75 ± 4.10 cpm to 16.50 ± 4.42 cpm (p = 0.007). PFV at 6 m and 0.4 m increased from 19.49 ± 6.77∆ to 22.19 ± 6.64∆ (p < 0.001) and 20.51 ± 7.05∆ to 22.69 ± 6.44∆ (p = 0.012), respectively. After 12 weeks, convergence insufficiency symptom survey scores for cases with CI decreased significantly, with NPC improving from 7.0 to 0 cm, 6.0 to 5.8 cm, and 6.0 to 4.7 cm. PFV increased from 10 to 25∆, 20 to 30∆, and 25 to 50∆. Conclusion This preliminary study showed the effect of ADRRPs on improving vergence abilities. Further studies are needed to investigate the long-term sustainability and effects in a larger population of individuals with CI of this approach.
This study evaluated binocular visual function using automatic dual rotational Risley prisms (ADRRPs) to measure phoria and vergence ranges. Thirty-nine (mean age: 21.82 ± 1.10 years; age range: 20–24 years) healthy adults with normal binocular vision participated. Each underwent baseline refraction exams followed by phoria and vergence tests conducted using both a phoropter with Maddox rods and the ADRRPs. The results revealed a strong positive correlation between the two instruments for distance phoria (r = 0.959, p < 0.001) and near-phoria measurements (r = 0.968, p < 0.001). For vergence testing, positive fusional vergence (PFV) at distance showed a moderate-to-strong correlation for break points (r = 0.758, p < 0.001) and a moderate correlation for recovery points (r = 0.452, p < 0.001). Negative fusional vergence (NFV) at distance demonstrated a strong correlation for break points (r = 0.863, p < 0.001) and a moderate correlation for recovery points (r = 0.458, p < 0.01). Near-vergence testing showed moderate-to-strong correlations for break points (r = 0.777, p < 0.001) and recovery points (r = 0.623, p < 0.001). The inclusion of Bland–Altman analysis provides a more comprehensive evaluation of agreement between ADRRPs and the phoropter. While strong correlations were observed, systematic bias and LoA indicate that these methods are not perfectly interchangeable. The ADRRPs demonstrated potential for binocular vision assessment but require further validation for clinical application.