Sudheer Kumar Yamsani

Dr. Sudheer Kumar Yamsani

orcid

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2015 in Ecological Engineering
Verified
Journal Article
Closed access
SBS. Bordoloi
S. Bordoloi
SYSudheer Kumar Yamsani
Sudheer Kumar Yamsani
Ankit GargAnkit Garg
Ankit Garg
SSS. Sreedeep
S. Sreedeep
SBS. Borah
S. Borah

1 February 2019 in Journal of Environmental Engineering
Verified
Journal Article
Closed access
CGC. B. Gupt
C. B. Gupt
SYSudheer Kumar Yamsani
Sudheer Kumar Yamsani
APA. Prakash
A. Prakash
CMC. R. Medhi
C. R. Medhi
SSS. Sreedeep
S. Sreedeep
This study demonstrates the importance of selecting an appropriate liquid-to-solid ratio (L∶S ) for batch sorption study (BSS) of bentonite (BE). The current recommended L∶S is 20 for BSS of soils and sediments, which works well for most of the soils/sediments. However, for expansive soil like BE, L∶S=20 was found to be inadequate due to the formation of thick gel like consistency preventing proper interaction of metal ion with solid surface. This resulted in considerable underestimation of sorption capacity of BE. Effort was made to identify appropriate L∶S for BE for which there is no specific guideline available in the literature. Under controlled pH condition and Pb2+ as the model heavy metal ion, it was noted that the sorption capacity of BE increases with L∶S beyond 20 and with an increase in initial metal ion concentration. The highest percentage removal of Pb2+ was observed at L∶S=50 and lowest at L∶S=100 for initial concentration greater than 300  mg/L . The minimum L∶S possible for BE is 20, below which the interaction between the solution and soil solids becomes difficult due to formation of a thick gel like consistency. The interaction of BE with Pb2+ was further investigated from the results of field emission scanning electron microscopy (FESEM) integrated with energy dispersive X-ray spectroscopy (EDX). Fourier transform infrared (FTIR) spectrometer was used to identify the variations in interaction between the Pb2+ ions and functional group present on BE for various L∶S . It was concluded that for all practical purposes, L∶S=50 is a suitable ratio for determining sorption capacity of expansive soil like BE.

1 January 2019 in Advances in Civil Engineering Materials
Verified
Journal Article
Closed access
BGBiplab Ghosh
Biplab Ghosh
SPSreeja Pekkat
Sreeja Pekkat
SYSudheer Kumar Yamsani
Sudheer Kumar Yamsani
Soil hydraulic conductivity is a mandatory input for determining water and solute transport through soils. There are several well-established infiltrometers and permeameters for measuring in situ hydraulic conductivity. Infiltrometers measure hydraulic conductivity based on water entry into an unsaturated soil at the soil-atmosphere boundary, whereas permeameters measure the flow of water from one point to another within the soil mass. This difference in measurement philosophy, along with the methods of analysis involved in the measurement, may result in varying estimates of in situ hydraulic conductivity. This study performs an evaluation among three infiltrometers (double ring infiltrometer [DRI] and two disc infiltrometers) and two permeameters (Guelph permeameter [GP] and laboratory permeameter) for measuring hydraulic conductivity. The primary objective of this study is to appraise the variability in the measurement of in situ hydraulic conductivity for identical field conditions using different infiltrometers and permeameters. The study indicated that all the permeameters and infiltrometers exhibited reasonably good repeatability in measurements. Unlike infiltrometers, the hydraulic conductivity determined from permeameters was found to exhibit similar values for two different seasons. Infiltrometers were found to be highly sensitive to alteration in the surface pore structure due to the soil-atmosphere interaction. The statistical evaluation indicated a negative bias of disc infiltrometers when compared with DRI, whereas the comparison of disc infiltrometers has shown a bias close to zero. The results of the GP closely compared with laboratory permeameter. Both the disc infiltrometers exhibited a negative bias and weak correlation with GP measurements. In the absence of parity between infiltrometer and permeameter, the former may be a better choice for including the effect of soil surface alteration on hydrological modeling, whereas the latter can be handy for modeling water redistribution within the soil mass.

19 September 2023 in Geotechnical Testing Journal
Verified
Journal Article
Closed access
PDF file
AGAravind Gaddam
Aravind Gaddam
SYSudheer Kumar Yamsani
Sudheer Kumar Yamsani
Black cotton soils are extremely problematic because they are susceptible to large volume changes with variation in moisture contents. These soils are conventionally stabilized with ordinary portland cement and lime, but the production/utilization of these traditional stabilizers is highly energy intensive, involves quarrying, and emits large quantities of carbon dioxide (CO2) into the atmosphere. Geopolymer is a promising alternative to these stabilizers because it provides high strength, consumes low energy, and emits low CO2 during synthesis and application. In this study, geopolymers synthesized from coal gangue (waste generated during coal mining) and ground granulated blast furnace slag (GGBS; by-product from the iron and steel industry) binders were evaluated for treating black cotton soil. A mixture of sodium silicate and sodium hydroxide is used as an alkaline activator solution for geopolymerization. An attempt is further made to identify the optimal dosages of geopolymer by evaluating the strength and durability characteristics of geopolymer-treated black cotton soil mixtures. X-ray diffraction and scanning electron microscopy were further conducted to distinguish the mineralogical and microstructural changes that occurred because of geopolymerization. From this study, it is found that using coal gangue alone as a precursor in geopolymer is good at improving the strength of black cotton soil but observed to be weak in durability. Hence, an attempt is further made to synthesize a better-performing geopolymer with a combination of GGBS and coal gangue, i.e., effective in both strength and durability aspects. Optimal geopolymer identified in this study can be a sustainable alternative to traditional stabilizers in improving black cotton soils for geotechnical subgrade applications.

1 January 2019 in Advances in Civil Engineering Materials
Verified
Journal Article
Closed access
JSJanarul Shaikh
Janarul Shaikh
SYSudheer Kumar Yamsani
Sudheer Kumar Yamsani
SSSreedeep Sekharan
Sreedeep Sekharan
RRRavi R. Rakesh
Ravi R. Rakesh
Accurate measurement of volumetric water content (θ) is essential for studying soil-water interaction efficiently. The accuracy of various types of θ measuring sensors needs to be ascertained before deploying in specific projects. The objective of this study is to evaluate the performance of electromagnetic 5TM sensor for real-time monitoring of θ in a cover system (CS). This CS is provided on top of the hazardous waste containment to isolate it from the surrounding environment and minimize interaction with rain water. The CS consists of different layers of soil and geosynthetics that interact with the atmosphere and undergo changes in θ with changing local weather conditions. Because θ governs the hydraulic and mechanical characteristics of geomaterials, its variation is monitored as a function of space and time for evaluating the performance of CS. Performance assessment of 5TM sensor was carried out under controlled conditions for ten different soil materials that may find application in CS. This study indicates the importance of material specific calibration of a 5TM sensor for improving its measurement accuracy before deploying it for field monitoring. The accuracy of 5TM measurement was marginally better when the polynomial calibration equation was adopted as compared to linear calibration. In the absence of soil-specific calibration, the new set of calibration parameters proposed in this study can be used for the generic soils used in CS. With improved accuracy of 5TM, it was shown that the error in the determination of soil water storage for different layers of a trial CS reduced from 15 to 0.4 %.

6 August 2016 in International Journal of Geosynthetics and Ground Engineering
Verified
Journal Article
Closed access
PDF file
SYSudheer Kumar Yamsani
Sudheer Kumar Yamsani
SSS. Sreedeep
S. Sreedeep
RRR. R. Rakesh
R. R. Rakesh