This study demonstrates the importance of selecting an appropriate liquid-to-solid ratio ( ) for batch sorption study (BSS) of bentonite (BE). The current recommended is 20 for BSS of soils and sediments, which works well for most of the soils/sediments. However, for expansive soil like BE, was found to be inadequate due to the formation of thick gel like consistency preventing proper interaction of metal ion with solid surface. This resulted in considerable underestimation of sorption capacity of BE. Effort was made to identify appropriate for BE for which there is no specific guideline available in the literature. Under controlled pH condition and as the model heavy metal ion, it was noted that the sorption capacity of BE increases with beyond 20 and with an increase in initial metal ion concentration. The highest percentage removal of was observed at and lowest at for initial concentration greater than . The minimum possible for BE is 20, below which the interaction between the solution and soil solids becomes difficult due to formation of a thick gel like consistency. The interaction of BE with was further investigated from the results of field emission scanning electron microscopy (FESEM) integrated with energy dispersive X-ray spectroscopy (EDX). Fourier transform infrared (FTIR) spectrometer was used to identify the variations in interaction between the ions and functional group present on BE for various . It was concluded that for all practical purposes, is a suitable ratio for determining sorption capacity of expansive soil like BE.
1 January 2019 in Advances in Civil Engineering Materials
Soil hydraulic conductivity is a mandatory input for determining water and solute transport through soils. There are several well-established infiltrometers and permeameters for measuring in situ hydraulic conductivity. Infiltrometers measure hydraulic conductivity based on water entry into an unsaturated soil at the soil-atmosphere boundary, whereas permeameters measure the flow of water from one point to another within the soil mass. This difference in measurement philosophy, along with the methods of analysis involved in the measurement, may result in varying estimates of in situ hydraulic conductivity. This study performs an evaluation among three infiltrometers (double ring infiltrometer [DRI] and two disc infiltrometers) and two permeameters (Guelph permeameter [GP] and laboratory permeameter) for measuring hydraulic conductivity. The primary objective of this study is to appraise the variability in the measurement of in situ hydraulic conductivity for identical field conditions using different infiltrometers and permeameters. The study indicated that all the permeameters and infiltrometers exhibited reasonably good repeatability in measurements. Unlike infiltrometers, the hydraulic conductivity determined from permeameters was found to exhibit similar values for two different seasons. Infiltrometers were found to be highly sensitive to alteration in the surface pore structure due to the soil-atmosphere interaction. The statistical evaluation indicated a negative bias of disc infiltrometers when compared with DRI, whereas the comparison of disc infiltrometers has shown a bias close to zero. The results of the GP closely compared with laboratory permeameter. Both the disc infiltrometers exhibited a negative bias and weak correlation with GP measurements. In the absence of parity between infiltrometer and permeameter, the former may be a better choice for including the effect of soil surface alteration on hydrological modeling, whereas the latter can be handy for modeling water redistribution within the soil mass.
Black cotton soils are extremely problematic because they are susceptible to large volume changes with variation in moisture contents. These soils are conventionally stabilized with ordinary portland cement and lime, but the production/utilization of these traditional stabilizers is highly energy intensive, involves quarrying, and emits large quantities of carbon dioxide (CO2) into the atmosphere. Geopolymer is a promising alternative to these stabilizers because it provides high strength, consumes low energy, and emits low CO2 during synthesis and application. In this study, geopolymers synthesized from coal gangue (waste generated during coal mining) and ground granulated blast furnace slag (GGBS; by-product from the iron and steel industry) binders were evaluated for treating black cotton soil. A mixture of sodium silicate and sodium hydroxide is used as an alkaline activator solution for geopolymerization. An attempt is further made to identify the optimal dosages of geopolymer by evaluating the strength and durability characteristics of geopolymer-treated black cotton soil mixtures. X-ray diffraction and scanning electron microscopy were further conducted to distinguish the mineralogical and microstructural changes that occurred because of geopolymerization. From this study, it is found that using coal gangue alone as a precursor in geopolymer is good at improving the strength of black cotton soil but observed to be weak in durability. Hence, an attempt is further made to synthesize a better-performing geopolymer with a combination of GGBS and coal gangue, i.e., effective in both strength and durability aspects. Optimal geopolymer identified in this study can be a sustainable alternative to traditional stabilizers in improving black cotton soils for geotechnical subgrade applications.
1 January 2019 in Advances in Civil Engineering Materials
Accurate measurement of volumetric water content (θ) is essential for studying soil-water interaction efficiently. The accuracy of various types of θ measuring sensors needs to be ascertained before deploying in specific projects. The objective of this study is to evaluate the performance of electromagnetic 5TM sensor for real-time monitoring of θ in a cover system (CS). This CS is provided on top of the hazardous waste containment to isolate it from the surrounding environment and minimize interaction with rain water. The CS consists of different layers of soil and geosynthetics that interact with the atmosphere and undergo changes in θ with changing local weather conditions. Because θ governs the hydraulic and mechanical characteristics of geomaterials, its variation is monitored as a function of space and time for evaluating the performance of CS. Performance assessment of 5TM sensor was carried out under controlled conditions for ten different soil materials that may find application in CS. This study indicates the importance of material specific calibration of a 5TM sensor for improving its measurement accuracy before deploying it for field monitoring. The accuracy of 5TM measurement was marginally better when the polynomial calibration equation was adopted as compared to linear calibration. In the absence of soil-specific calibration, the new set of calibration parameters proposed in this study can be used for the generic soils used in CS. With improved accuracy of 5TM, it was shown that the error in the determination of soil water storage for different layers of a trial CS reduced from 15 to 0.4 %.
6 August 2016 in International Journal of Geosynthetics and Ground Engineering