Tzu-Wen Kuo

Dr. Tzu-Wen Kuo

Architect business office, Taipei, Taiwan
orcid

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
TKTzu-Wen Kuo
Tzu-Wen Kuo
CLChing-Yuan Lin
Ching-Yuan Lin
YCYing-Ji Chuang
Ying-Ji Chuang
Gary Li-Kai HsiaoGary Li-Kai Hsiao
Gary Li-Kai Hsiao
Fire smoke reduces the visibility of emergency direction signs, rendering them ineffective for providing appropriate guidance along evacuation routes in a fire situation. This is problematic because civilians may select evacuation routes that expose them to smoke or fire in a burning building. This study proposed using a smartphone voice-guided evacuation system (SVGES) to provide alternative evacuation routes for civilians trapped at a fire scene. To verify the efficacy of the SVGES, experiments were conducted with 26 participants in a simulated fire scenario. The experimental results showed that when using the SVGES, the participants chose the safest evacuation route with a 100% successful evacuation rate.

26 May 2025 in Fire
Verified
Journal Article
Open access
PDF file
CYChieh-Hsiung Yang
Chieh-Hsiung Yang
CLChing-Yuan Lin
Ching-Yuan Lin
TKTzu-Wen Kuo
Tzu-Wen Kuo
Architectural design seeks to address many challenges, one of which is creating buildings that can quickly and safely evacuate people. Therefore, it is even more important to pay attention to the safety of personnel evacuation. Past disasters have shown that the number of casualties in large sports stadiums can be as severe as those caused by plane crashes. This study uses a case study approach to analyze the evacuation of spectators in a 40,000-seat stadium, comparing the practical application of three performance verification methods. The results indicate that Simulex’s visual dynamic simulation effectively reflects how walking speeds decrease in crowded conditions and how bottlenecks form along evacuation routes. People tend to gather at corners, leading to congestion and uneven distribution of evacuees, with several escape staircases being underutilized. The Guide to Safety at Sports Grounds is suitable for the early planning stages of architectural design, while the “Verification Guideline of Buildings Evacuation Safety Performance-based Design” is better suited for the detailed design phase to ensure compliance with the safety standard of evacuating spectators within 8 min. Compared to planning and designing based solely on regulations or empirical verification formulas, using visualization software allows for effective adjustments to evacuation routes before finalizing the design, balancing crowd flow across all safety exits and improving evacuation efficiency during the operational phase.

15 March 2025 in Fire
Verified
Journal Article
Open access
PDF file
TKTzu-Wen Kuo
Tzu-Wen Kuo
CLChing-Yuan Lin
Ching-Yuan Lin
This study aimed to shorten firefighter search times during indoor fires, allowing more people to be rescued, by enhancing disaster-prevention capabilities using building technologies. In indoor fires, fatalities are often caused by the failure of firefighters to rescue individuals in a timely manner. The question of how to effectively increase the probability of survival while waiting for rescue behind closed doors warrants in-depth research and analysis. Therefore, to ensure that people live in safe environments, there is an urgent need to develop a building door panel material with an emergency call function to prevent such incidents from occurring. Utilizing the PRISMA method, we conducted a comprehensive review of the existing literature to identify the key issues and limitations associated with the current search-and-rescue techniques. Subsequently, the identified primary factors were analyzed using the TRIZ method to determine the key factors that influence the success of rescuing trapped individuals, and a notification system was designed to address this issue. Based on the premise that it is advisable to wait for rescue during a fire, we utilized a smartphone to scan a QR code and transmit the exact location information to the fire department. Through extensive participation and feedback from firefighters, we developed a rescue notification door panel and obtained a patent for it. This system can significantly reduce the time required for search-and-rescue operations in fire incidents. The experimental results show a reduction of one-third in search times.

13 February 2025 in Preprints.org
Verified
Preprint
Open access
PDF file
TKTzu-Wen Kuo
Tzu-Wen Kuo
CLChing-Yuan Lin
Ching-Yuan Lin
This study aimed to shorten firefighter search times during indoor fires, allowing more people to be rescued, by enhancing disaster prevention capabilities using building technologies. In indoor fires, fatalities are often caused by the failure of firefighters to rescue individuals in a timely manner. The question of how to effectively increase the probability of survival while waiting for rescue behind closed doors warrants in-depth research and analysis. Therefore, to ensure that people live in safe environments, there is an urgent need to develop a building door panel material with an emergency call function to prevent such incidents from occurring. Utilizing the PRISMA method, we conducted a comprehensive review of the existing literature to identify the key issues and limitations associated with the current search-and-rescue techniques. Subsequently, the identified primary factors were analyzed using the TRIZ method to determine the key factors that influence the success of rescuing trapped individuals, and a notification system was designed to address this issue. Based on the premise that it is advisable to wait for rescue during a fire, we utilized a smartphone to scan a QR code and transmit the exact location information to the fire department. Through extensive participation and feedback from firefighters, we developed a rescue notification door panel and obtained a patent for it. This system can significantly reduce the time required for search-and-rescue operations in fire incidents. The experimental results show a reduction of one-third in search times.