To develop a rapid detection method for nonprotein nitrogen adulterants, this experiment sets up a set of point-scan Raman hyperspectral imaging systems to qualitatively distinguish and quantitatively and positionally analyze samples spiked with a single nonprotein nitrogen adulterant and samples spiked with a mixture of nine nonprotein nitrogen adulterants at different concentrations (5 × 10–3 to 2.000%, w/w). The results showed that for samples spiked with single nonprotein nitrogen adulterants, the number of pixels corresponding to the adulterant in the region of interest increased linearly with an increase in the analyte concentration, the average coefficient of determination (R2) was above 0.99, the minimum detection concentration of nonprotein nitrogen adulterants reached 0.010%, and the relative standard deviation (RSD) of the predicted concentration was less than 6%. For the sample spiked with a mixture of nine nonprotein nitrogen adulterants, the standard curve could be used to accurately predict the additive concentration when the additive concentration was greater than 1.200%. The detection method established in this study has good accuracy, high sensitivity, and strong stability. It provides a method for technical implementation of real-time and rapid detection of adulterants in milk powder at the port site and has good application and promotion prospects.
To construct a reliable discrimination model for determining milk geographical origin, stable isotope ratios including δ13C, δ15N and δ18O, 51 elements and 35 fatty acids (FAs) in milk samples from Australia, New Zealand and Austria were detected and analyzed. It is found that all of the stable isotope ratios in the milk samples of Australia are the highest, followed by those of the samples from New Zealand and Austria. In addition, 14 elements and 8 FAs show different contents in the samples of different countries at the significance level of P < 0.05. Based on these results, a multivariate model with good robustness and predictive ability for authenticating milk origin (R2X = 0.693, Q2 = 0.854) was successfully constructed. Element contents and stable isotope ratios are more reliable variables for milk origin discrimination and Rb, δ18O, Tl, Ba, Mo, Sr, δ15N, Cs, As, Eu, C20:4n6, Sc, C13:0, K, Ca and C16:1n7 are the critical markers in the multivariate model for verifying milk origin.
Steroids are widely abused due to their ability to promote protein synthesis, enhance muscle growth, and improve athletic performance, leading to significant unfair competition. This review aims to provide scientific support for anti-doping.
The current detection method of carbendazim suffers from the disadvantages of complicated preprocessing and long cycle time. In order to solve the problem of rapid quantitative screening of finite contaminants, this article proposed a qualitative method based on characteristic peaks and a semi-quantitative method based on threshold to detect carbendazim in apple, and finally the method is evaluated by a validation system based on binary output. The results showed that the detection limit for carbendazim was 0.5 mg/kg, and the detection probability was 100% when the concentration was no less than 1 mg/kg. The semi-quantitative analysis method had a false positive rate of 0% and 5% at 0.5 mg/kg and 2.5 mg/kg, respectively. The results of method evaluation showed that when the added concentration was greater than 2.5 mg/kg, the qualitative detection method was consistent with the reference method. When the concentration was no less than 5 mg/kg, the semi-quantitative method is consistent between different labs. The semi-quantitative method proposed in this study can achieve the screening of finite contaminants in blind samples and simplify the test validation process through the detection probability model, which can meet the needs of rapid on-site detection and has a good application prospect.
1 January 2018 in Chinese Journal of Chromatography
A liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) method was established for the identification of meat marker peptides and quantitative detection of common exogenous meat in mutton adulteration. Samples were prepared by protein extraction, trypsin hydrolysis, and solid phase extraction. Proteins and peptides were identified using ultra-performance liquid chromatography-quadrupole/electrostatic orbitrap-high resolution mass spectrometry (UPLC-Q/Exactive-HRMS) combined with Proteinpilot software. Twenty species-specificity marker peptides in mutton, duck, pork, and chicken were identified by comparison of the basic local alignment search tool (BLAST) with the Uniprot database. Verification and multiple reaction monitoring (MRM) of these marker peptides were performed quantitatively using a UPLC-triple-quadrupole mass spectrometry (QqQ-MS) system. Duck, pork, and chicken were added to mutton at mass percentages of 1%, 5%, 10%, 20%, and 50%. The limit of detection for the adulterants was 0.25% for duck, 0.17% for pork, and 0.10% for chicken.