This article presents methods and results of experimental research to determine the power consumed when driving the working bodies of the straw bedding mobile spreader to cover cow stalls (boxes). Analysis of the design and mode parameters of the rotary finger working body influence on the energy consumption of the bedding material spreading process is carried out. Using the experimental data, it was established that the power consumed to drive the rotary finger working body of the mobile straw bedding spreader, at the tractor power take-off (PTO) shaft rotation speed of 540 min−1, the forward unit speed of 2 km/h, and performance of 1.5 kg/s, is equal to 7.633 kW. In this case, due to the installation of a rotary finger working body for spreading straw bedding, the power consumption increased by 9%. This increase will not have a significant impact on the overall energy consumption of the spreading bedding material working process, because this class tractor power reserve allows its use.
The object of the present research is a machine-tractor unit based on a tractor consisting of an energy (high-energy tractor—EM) and a technological (additional traction axle—TM) module. This tractor uses three-row crop cultivators, each with an operating width of 4.2 m. One of these cultivators is attached centrally to the technological module, and the other two are connected to the sides of the energy module in its front part. The research aimed to determine the influence degree of such a unit scheme and design parameters on the stability of its movement in the horizontal plane. The theoretical analysis was performed using amplitude (AFC) and phase (PFC) frequency characteristics obtained based on the developed mathematical model of the modular unit movement when it processes a disturbing effect. The difference in traction resistances of the unit’s side cultivators was adopted as the latter. Finally, it was established that blocking the vertical hinge of the TM contributes to a significant increase in the unit motion stability. The practical implementation of this method of joining EM and TM in the horizontal plane allows the unit to work out a disturbing influence in the frequency range 0.65–5.50 s−1 to eliminate the resonant AFC peaks and reduce their value. When the TM hinge is locked at a torque oscillation frequency of 2.5 s−1, the AFC is 2.82 times less than when it is free. Blocking the TM vertical hinge increases the delay in the unit’s response to a disturbance. At an oscillation frequency of the latter of 1.5 s−1, this delay is 0.6 s, and at a frequency of 0.5 s−1, it increases by more than three times, reaching a level of 1.9 s.