Jose Fortunato Oliden

Prof. Jose Fortunato Oliden

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications

1 May 2023
Verified
Book Chapter
Closed access
PDF file
EGEnzo Giraldo
Enzo Giraldo
JMJuan Matos
Juan Matos
LRLeonardo Nikolai Vinces Ramos
Leonardo Nikolai Vinces Ramos
JOJose Fortunato Oliden
Jose Fortunato Oliden
JRJulio Ronceros
Julio Ronceros

27 February 2025 in Sensors
Verified
Journal Article
Open access
PDF file
COCarmen Ortiz
Carmen Ortiz
JHJorge E. Alva Hurtado
Jorge E. Alva Hurtado
JOJose Fortunato Oliden
Jose Fortunato Oliden
AJAlejandrina Nelly Huarcaya Junes
Alejandrina Nelly Huarcaya Junes
GSGROVER RIVEROS SOTO
GROVER RIVEROS SOTO
RSRoberto Freddy Raucana Sulca
Roberto Freddy Raucana Sulca
Energy measurement in dynamic penetration tests is key to correctly interpreting test results and ensuring comparable geotechnical data. Although commercial devices are widely used, their high cost limits adoption in developing regions such as Peru, affecting the accuracy of soil evaluation in many geotechnical studies. In this context, this research presents an energy measurement system called Kallpa, which uses low-cost electronic components to digitize sensor signals during Standard Penetration Tests (SPTs). Kallpa employs high-resolution analog-to-digital converters (ADCs) with an advanced sampling frequency, processing and storing data via a Raspberry Pi 4 microcomputer. The sensors, including accelerometers and strain gauges, were calibrated and compared with the Pile Driving Analyzer (PDA) to validate their accuracy in the Kallpa system. This study involved sixteen Standard Penetration Tests (SPTs) conducted in various regions of Peru using donut hammers and two tests involving automatic hammers. The results demonstrate that the Kallpa system is comparable to other energy measurement devices on the market, such as the Dynamic Penetration Test (DPT), which provides accurate SPT energy measurements. The Kallpa Processor (Version 1.0) software was developed to perform data acquisition and calibration, analyzing approximately 500 hammer blows and comparing peak values with those of the Pile Driving Analyzer. The data collected by Kallpa’s sensors strongly agreed with the PDA data, validating the reliability of the device. The Energy Transfer Ratio (ETR) for manual hammers ranged from 43.5% to 68.4%, with an average of 58.9%, whereas automatic hammers presented ETR values between 82% and 87%. The correction of the N60 blow count allowed for the estimation of the relative density of soils evaluated at different depths and locations across Peru.

31 December 2025 in Sensors
Verified
Journal Article
Open access
PDF file
COCarmen Ortiz
Carmen Ortiz
JHJorge E. Alva Hurtado
Jorge E. Alva Hurtado
RSRoberto Freddy Raucana Sulca
Roberto Freddy Raucana Sulca
MIMichael Alexander Chipana Inti
Michael Alexander Chipana Inti
JOJose Fortunato Oliden
Jose Fortunato Oliden
JAJOSÉ DANIEL VALVERDE AGREDA
JOSÉ DANIEL VALVERDE AGREDA
Accelerographs are essential instruments for quantifying strong ground motion, serving as the foundation of modern earthquake engineering. In Peru, the first accelerographic station was installed in Lima in 1944; since then, various institutions have promoted the expansion of the national network. However, this network’s spatial coverage and instrumentation remain insufficient to properly characterize strong motion and support seismic risk reduction policies. In this context, the KUYUY accelerograph is presented as a low-cost, low-noise device equipped with real-time telemetry and high-performance MEMS sensors. Its interoperability with the Intelligent Automatic Processing System (SIPA) enables real-time monitoring and automated signal analysis for seismic microzonation studies and rapid damage assessment, contributing to seismic risk reduction in Peru. The validation process included static gravity calibration, field comparison with a reference accelerograph, and an initial deployment in Lima and Yurimaguas. The results demonstrate the proposed accelerograph’s linear response, temporal stability, and amplitude consistency with respect to high-end instruments, with differences below 5–10%.

9 December 2024 in Pharmacia
Verified
Journal Article
Open access
JMJosé Luis Mantari
José Luis Mantari
DBDiego Bonifacio
Diego Bonifacio
FHFany Ponce Hinostroza
Fany Ponce Hinostroza
RPRoy Panduro
Roy Panduro
JOJose Fortunato Oliden
Jose Fortunato Oliden
Angel T. AlvaradoAngel T. Alvarado
Angel T. Alvarado
High-flow non-invasive ventilation (NIV) devices reduce the morbidity and mortality of COVID-19. The objective was to evaluate the use of the non-invasive ventilation device with high-flow helmet CPAP designed in Peru in patients with severe acute respiratory syndrome (COVID-19) hospitalized in the emergency services of five hospitals. Prospective multicenter and cross-sectional observational study from five hospitals from July to August 2020. 19 patients were recruited and divided into two groups (G-1 n = 10; G-2 n = 9) applying clinical and gasometric parameters as indicators of disease evolution upon hospital admission and within 24 hours. A progressive increase in these parameters was observed in those patients who used the NIVCPAP helmet within the first 24 hours. In G-01, improvement was evident in 90% (n = 9/10): PaO2 (range 48–137; average: 82.49 ± 8.07; p-value = 0.008), CO2 (25.2–51.0; 36.62 ± 2.62; p-value p = 0.327), and the PaO2/FiO2 coefficient (87–318; 191.5 ± 18.68). 10% of patients did not progress optimally, being subjected to endotracheal intubation and invasive mechanical ventilation. In G-02 the values ​​were %SatO2 (range 92–98; 96 ± 0.76) and the SaO2/FiO2 coefficient (214–228; 223.2 ± 1.80), indicating significant improvement within 24 hours (p < 0.001). It is concluded that the use of the CPAP helmet non-invasive ventilation (NIV) device contributes to improving gasometric values ​​and clinical condition. Being an alternative to recover typical cases of COVID-19 in all hospitals in Peru.