The main focus of this work is to extend the applicability of D-H parameter method to develop a kinematic model of a hybrid manipulator. A hybrid manipulator is a combination of open- and closed-loop chains and contains planar and spatial links. It has been found in the literature that D-H parameter method leads to ambiguities, when dealing with closed-loop chains. In this work, it has been observed that the D-H parameter method, when applied to a hybrid manipulator, results in an orientational inconsistency, because of which the method cannot be used to develop the kinematic model. In this article, the concept of dummy frames is proposed to resolve the orientational inconsistency and to develop the kinematic model of a hybrid manipulator. Moreover, the prototype of 7-degree-of-freedom hybrid manipulator, known as a surgeon-side manipulator to assist the surgeon during a medical surgery, is also developed to validate the kinematic model derived in this work.
14 September 2017 in International Journal of Nonlinear Sciences and Numerical Simulation
The cart-pendulum system is a typical benchmark problem in the control field. It is a fully underactuated system having one control input for two degrees-of-freedom (DOFs) system. It has highly nonlinear structure, which can be used to validate different nonlinear and linear controllers and has wide range of real-time (realistic) applications like rockets propeller, tank missile launcher, self-balancing robot, stabilization of ships, design of earthquake resistant buildings, etc. In this work, modeling, simulation and real-time control of a cart-pendulum system is performed. The mathematical model of the system is developed using Euler-Lagrange approach. In order to achieve a more realistic model, the actuator dynamics is considered in the mathematical model. The main aim of this work is to investigate the performance of two different control strategies- first to swing-up the pendulum to near unstable equilibrium region and second to stabilize the pendulum at unstable equilibrium point. The swing-up problem is addressed by using energy controller in which cart is accelerated by providing a force to the cart with a AC servo motor with the help of timing pulley arrangement. The initial velocity of the cart is taken into account to confirm swing-up in the restricted track length. The cart displacement in the restricted track length is verified by simulation and experimental test-run. The regulation problem of stabilization of pendulum is addressed by developing the controller using Pole Placement Controller (PPC) and LQR Controller (LQRC). Both the control strategies are performed analytically and experimentally using the Googoltech Linear Inverted Pendulum (GLIP) setup. The analytical results, simulated in MATLAB and SIMULINK environment, are found in close agreement with the experimental results. In order to demonstrate the effect of both the stabilizing controllers on the performance of the system, comparison of the experimental results is reported in this work. It is demonstrated experimentally that LQR controller outperforms the Pole Placement controller, in terms of reduction in the oscillations of the inverted pendulum (56 %), as well as the magnitude of maximum control input (66.7 %). Further, robustness of the closed-loop system is investigated by providing external disturbances.
12 June 2018 in Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
Over the last few decades, medical-assisted robots have been considered by many researchers, within the research domain of robotics. In this article, a 5-degrees-of-freedom spatial medical manipulator is analyzed for path planning, based on inverse kinematic solutions. Analytical methods have generally employed for finding the inverse kinematic solutions in earlier studies. However, this method is only appreciable in case of closed-form solutions. The unusual joint configurations of considered manipulator result in more complexity to attain the closed-form solutions, analytically. To overcome with shortcomings of analytical method, a non-traditional approach named adaptive neuro-fuzzy inference system is proposed under the class of artificial intelligent techniques. This article presents this neuro-fuzzy approach for desired path generation by 5-degrees-of-freedom manipulator. The estimation of percentage error between actual path and adaptive neuro-fuzzy inference system–generated path is done with respect to x, y, and z directions, respectively. Furthermore, the error between actual and predicted values regarding joint parameters is calculated for a certain arm matrix. The prototype of 5-degrees-of-freedom medical-assisted manipulator is developed at CSIR-CSIO Laboratory Chandigarh, which is also termed as patient-side manipulator to be utilized in robot-assisted surgery. Through the simulation runs, in this work, it is found that the results from adaptive neuro-fuzzy inference system approach are quite satisfactory and acceptable.
31 March 2018 in International Journal of Nonlinear Sciences and Numerical Simulation
From the last five decades, inverted pendulum (IP) has been considered as a benchmark problem in the control literature due to its inherit nature of instability, non-linearity and underactuation. Its applicability in wide range of practical systems, demands the need of a robust controller. It is found in the literature that wide range of controllers had been tested on this problem, out of which the most robust being sliding mode controller while the most optimal being linear quadratic regulator (LQR) controller. The former has a problem of discontinuity and chattering, while the latter lacks the property of robustness. To address the robustness issue in LQR controller, this paper proposes a novel robust LQR-based adaptive neural based fuzzy inference system controller, which is a hybrid of LQR and fuzzy inference system. The proposed controller is designed and implemented on rotary inverted pendulum. Further, to validate the robustness of proposed controller to parametric uncertainties, pendulum mass is varied. Simulation and experimental results show that as compared to LQR controller, the proposed controller is robust to variations in pendulum mass and has shown satisfactory performance.
4 August 2016 in Proceedings of the National Academy of Sciences, India Section A: Physical Sciences