László Bottyán

Dr. László Bottyán


Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2013 in Review of Scientific Instruments
Verified
Journal Article
Closed access
LBLászló Bottyán
László Bottyán
DMD. G. Merkel
D. G. Merkel
BNB. Nagy
B. Nagy
JFJ. Füzi
J. Füzi
SSSz. Sajti
Sz. Sajti
JMJ. Major
J. Major
The setup, capabilities, and operation parameters of the neutron reflectometer GINA, the recently installed “Grazing Incidence Neutron Apparatus” at the Budapest Neutron Centre, are introduced. GINA, a dance-floor-type, constant-energy, angle-dispersive reflectometer is equipped with a 2D position-sensitive detector to study specular and off-specular scattering. Wavelength options between 3.2 and 5.7 Å are available for unpolarized and polarized neutrons. Spin polarization and analysis are achieved by magnetized transmission supermirrors and radio-frequency adiabatic spin flippers. As a result of vertical focusing by a five-element pyrolytic graphite monochromator, the reflected intensity from a 20 × 20 mm2 sample has been doubled. GINA is dedicated to studies of magnetic films and heterostructures, but unpolarized options for non-magnetic films, membranes, and other surfaces are also provided. Shortly after its startup, reflectivity values as low as 3 × 10−5 have been measured by the instrument. The instrument capabilities are demonstrated by a non-polarized and a polarized reflectivity experiment on a Si wafer and on a magnetic film of [62Ni/natNi]5 isotope-periodic layer composition. The facility is now open for the international user community. Its further development is underway establishing new sample environment options and spin analysis of off-specularly scattered radiation as well as further decreasing the background.

1 February 2017 in Journal of Applied Crystallography
Verified
Journal Article
Closed access
PDF file
TVTamás Veres
Tamás Veres
SSSzilárd Sajti
Szilárd Sajti
LCLászló Cser
László Cser
SBSzabolcs Bálint
Szabolcs Bálint
LBLászló Bottyán
László Bottyán

30 April 2008 in Scripta Materialia
Verified
Journal Article
Closed access
AKAndrás Kovács
András Kovács
DMDániel G. Merkel
Dániel G. Merkel
FTFerenc Tanczikó
Ferenc Tanczikó
SSSvetoslav Stankov
Svetoslav Stankov
YHYoshihiko Hirotsu
Yoshihiko Hirotsu
LBLászló Bottyán
László Bottyán

26 May 2020 in bioRxiv
Verified
Preprint
Open access
PDF file
FPFabio Perissinotto
Fabio Perissinotto
VRValeria maria Rondelli
Valeria maria Rondelli
BSBeatrice Senigagliesi
Beatrice Senigagliesi
PBPaola Brocca
Paola Brocca
LALászló Almásy
László Almásy
PPPietro Parisse
Pietro Parisse
Extracellular vesicles (EVs) represent a potent intercellular communication system. Within a lipid bilayer such small vesicles transport biomolecules between cells and throughout the body, strongly influencing the fate of recipient cells. Due to their specific biological functions they have been proposed as biomarkers for various diseases and as optimal candidates for therapeutic applications. Despite of their extreme biological relevance, the small size (30 to a few hundred nanometers in diameter) of EVs still poses a great challenge for their isolation, quantification and biophysical/biochemical characterization, therefore the complex network of EVs and cells as well as their interaction remains to be further revealed. Here we propose a multiscale platform based on Atomic Force Microscopy, Small Angle X-ray Scattering, Small Angle Neutron Scattering and Neutron Reflectometry to reveal structure-function correlations of purified EVs through the analysis of their interaction with model membrane systems, in form of both supported lipid bilayers and suspended unilamellar vesicles of variably complex composition. The analysis reveals a strong interaction of EVs with the model membranes and preferentially with liquid ordered raft-like lipid domains, and opens the way to understand uptake mechanisms in different vesicle to cell membrane relative compositions.

19 November 2012 in arXiv
Verified
Preprint
Open access
PDF file
LBLászló Bottyán
László Bottyán
DMD. G. Merkel
D. G. Merkel
BNB. Nagy
B. Nagy
JFJ. Füzi
J. Füzi
SSSz. Sajti
Sz. Sajti
JMJ. Major
J. Major
The setup, capabilities and operation parameters of the neutron reflectometer GINA, the recently installed "Grazing Incidence Neutron Apparatus" at the Budapest Neutron Centre, are introduced. GINA, a dance-floor-type, constant-energy, angle-dispersive reflectometer is equipped with a 2D position-sensitive detector to study specular and off-specular scattering. Wavelength options between 3.2 and 5.7 {\AA} are available for unpolarized and polarized neutrons. Spin polarization and analysis are achieved by magnetized transmission supermirrors and radio-frequency adiabatic spin flippers. As a result of vertical focusing by the five-element (pyrolytic graphite) monochromator the reflected intensity from a 20x20 mm sample has doubled. GINA is dedicated to studies of magnetic films and heterostructures, but unpolarized options for non-magnetic films, membranes and other surfaces are also provided. Shortly after its startup, reflectivity values as low as 3x10-5 have been measured on the instrument. The facility is now open for the international user community, but its development is continuing mainly to establish new sample environment options, the spin analysis of off-specularly scattered radiation and further decrease of the background.