Yanxue Cai

Yanxue Cai

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 May 2018 in Molecules
Verified
Journal Article
Open access
PDF file
YCYanxue Cai
Yanxue Cai
KKKeren Kang
Keren Kang
QLQianru Li
Qianru Li
YWYu Wang
Yu Wang
XHXiaowei He
Xiaowei He
A reliable lateral flow immunoassay (LFIA) based on a facile one-step synthesis of single microspheres in combining with immunochromatography technique was developed to establish a new point-of-care test (POCT) for the rapid and early detection of cardiac troponin I (cTnI), a kind of cardiac specific biomarker for acute myocardial infarction (AMI). The double layered microspheres with clear core-shell structures were produced using soap-free emulsion polymerization method with inexpensive compounds (styrene and acrylic acid). The synthetic process was simple, rapid and easy to control due to one-step synthesis without any complicated procedures. The microspheres are nanostructure with high surface area, which have numerous carboxyl groups on the out layer, resulting in high-efficiency coupling between the carrier and antibody via amide bond. Meanwhile, the red fluorescent dye, Nile-red (NR), was wrapped inside the microspheres to improve its stability, as well to reduce the background noise, because of its higher emission wavelength than interference from real plasma samples. The core-shell structures provided different functional areas to separate antibody and dyes, so the immunoassay has highly sensitive, wide working curves in the range of 0–40 ng/mL, low limits of detection (LOD) at 0.016 ng/mL, and limits of quantification (LOQ) at 0.087 ng/mL with coefficient of variations (CV) of 10%. This strategy suggested an outstanding platform for LFIA, with good reproducibility and stability to straightforwardly analyze the plasma samples without washing steps, thereby reducing the operating procedures for non-professionals and promoting detection efficiency. The whole detection process can be completed in less than 15 min. This novel immunoassay offers a reliable and favorable analytical result by detecting the real samples, indicating that it holds great potential as a new alternative for biomolecule detection in complex samples, for the early detection of cardiac specific biomarkers.

1 October 2019 in Journal of Functional Foods
Verified
Journal Article
Closed access
YCYan Xue Cai
Yan Xue Cai
JWJi Hui Wang
Ji Hui Wang
CMCatherine McAuley
Catherine McAuley
MAMary Ann Augustin
Mary Ann Augustin
YCYanxue Cai
Yanxue Cai

6 March 2023 in Food & Function
Verified
Journal Article
Closed access
PDF file
YHYao-Yao Hu
Yao-Yao Hu
SXShan Xiao
Shan Xiao
BWBo Wang
Bo Wang
RXRui-Hong Xie
Rui-Hong Xie
YCYanxue Cai
Yanxue Cai
JWJihui Wang
Jihui Wang
The antioxidant peptides isolated from Xuanwei ham could be transported by the small intestinal epithelial and have protective effects on H2O2-induced damaged HepG2 cells.

1 January 2022 in Food Science and Technology
Verified
Journal Article
Open access
JWJihui Wang
Jihui Wang
XCXiangyu Chen
Xiangyu Chen
HWHan Wang
Han Wang
SXShan Xiao
Shan Xiao
BWBo Wang
Bo Wang
YCYanxue Cai
Yanxue Cai