Roger J. Narayan

Dr. Roger J. Narayan

North Carolina State University, Raleigh, USA
+1
orcid

Research Focus & Metrics

Academic Career Length

27Years (2000-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 March 2008 in JOM
Verified
Journal Article
Closed access
PDF file
AKA. S. Karakoti
A. S. Karakoti
NMN. A. Monteiro-Riviere
N. A. Monteiro-Riviere
RAR. Aggarwal
R. Aggarwal
JDJ. P. Davis
J. P. Davis
Roger J. NarayanRoger J. Narayan
Roger J. Narayan
SSS. Seal
S. Seal

29 January 2007 in International Journal of Applied Ceramic Technology
Verified
Journal Article
Closed access
PDF file
AOAleksandr Ovsianikov
Aleksandr Ovsianikov
Boris ChichkovBoris Chichkov
Boris Chichkov
PMP. Mente
P. Mente
NMN. A. Monteiro‐Riviere
N. A. Monteiro‐Riviere
ADA. Doraiswamy
A. Doraiswamy
Roger J. NarayanRoger J. Narayan
Roger J. Narayan

16 July 2020 in Journal of Materials Chemistry B
Verified
Journal Article
Closed access
PDF file
Bin ZhangBin Zhang
Bin Zhang
Jie HuangJie Huang
Jie Huang
Roger J. NarayanRoger J. Narayan
Roger J. Narayan
The tissue engineering approach for repairing osteochondral (OC) defects involves the fabrication of a biological tissue scaffold that mimics the physiological properties of natural OC tissue (e.g., the gradient transition between the cartilage surface and the subchondral bone). The OC tissue scaffolds described in many research studies exhibit a discrete gradient (e.g., a biphasic or tri/multiphasic structure) or a continuous gradient to mimic OC tissue attributes such as biochemical composition, structure, and mechanical properties. One advantage of a continuous gradient scaffold over biphasic or tri/multiphasic tissue scaffolds is that it more closely mimics natural OC tissue since there is no distinct interface between each layer. Although research studies to this point have yielded good results related to OC regeneration with tissue scaffolds, differences between engineered scaffolds and natural OC tissue remain; due to these differences, current clinical therapies to repair OC defects with engineered scaffolds have not been successful. This paper provides an overview of both discrete and continuous gradient OC tissue scaffolds in terms of cell type, scaffold material, microscale structure, mechanical properties, fabrication methods, and scaffold stimuli. Fabrication of gradient scaffolds with three-dimensional (3D) printing is given special emphasis due to its ability to accurately control scaffold pore geometry. Moreover, the application of computational modeling in OC tissue engineering is considered; for example, efforts to optimize the scaffold structure, mechanical properties, and physical stimuli generated within the scaffold–bioreactor system to predict tissue regeneration are considered. Finally, challenges associated with the repair of OC defects and recommendations for future directions in OC tissue regeneration are proposed.

1 February 2013 in Journal of Adhesion Science and Technology
Verified
Journal Article
Closed access
SGShaun D. Gittard
Shaun D. Gittard
BCBo Chen
Bo Chen
HXHuadong Xu
Huadong Xu
AOAleksandr Ovsianikov
Aleksandr Ovsianikov
Boris ChichkovBoris Chichkov
Boris Chichkov
Roger J. NarayanRoger J. Narayan
Roger J. Narayan
Microneedles are small-scale devices that may be used for drug delivery and biosensing. In this study, the forces required for mechanical failure, the modes of mechanical failure, as well as the mechanisms for microneedle penetration into porcine skin were examined. Microneedles produced from the acrylate-based polymer e-Shell 200 using an indirect rapid prototyping approach involving two-photon polymerization and poly(dimethylsiloxane) micromolding were found to possess sufficient strength for penetration of porcine skin. The failure forces were an order of magnitude greater than the forces necessary for full insertion into the skin. Bending was the most common form of failure; an increasing aspect ratio and a decreasing tip diameter were associated with lower failure forces. Video captured during skin penetration revealed that microneedle penetration into the skin occurred by means of a series of insertions and not by means of a single insertion event. Images obtained during and after skin penetration confirmed microneedle penetration of skin as well as transdermal delivery of lucifer yellow dye. These findings shed insight into the mechanisms of microneedle penetration and failure, facilitating design improvements for polymer microneedles.

16 March 2011 in The Analyst
Verified
Journal Article
Closed access
PDF file
JWJoshua Ray Windmiller
Joshua Ray Windmiller
NZNandi Zhou
Nandi Zhou
MCMin-Chieh Chuang
Min-Chieh Chuang
GRGabriela Valdes Ramirez
Gabriela Valdes Ramirez
PSPadmanabhan Santhosh
Padmanabhan Santhosh
Joseph WangJoseph Wang
Joseph Wang
The design and characterization of a microneedle array-based carbon paste electrode towards minimally invasive electrochemical sensing are described. Arrays consisting of 3 × 3 pyramidal microneedle structures, each with an opening of 425 µm, were loaded with a metallized carbon paste transducer. The renewable nature of carbon paste electrodes enables the convenient packing of hollow non-planar microneedles with pastes that contain assorted catalysts and biocatalysts. Smoothing the surface results in good microelectrode-to-microelectrode uniformity. Optical and scanning electron micrographs shed useful insights into the surface morphology at the microneedle apertures. The attractive performance of the novel microneedle electrode arrays is illustrated in vitro for the low-potential detection of hydrogen peroxide at rhodium-dispersed carbon paste microneedles and for lactate biosensing by the inclusion of lactate oxidase in the metallized carbon paste matrix. Highly repeatable sensing is observed following consecutive cycles of packing/unpacking the carbon paste. The operational stability of the array is demonstrated as well as the interference-free detection of lactate in the presence of physiologically relevant levels of ascorbic acid, uric acid, and acetaminophen. Upon addressing the biofouling effects associated with on-body sensing, the microneedle carbon paste platform would be attractive for the subcutaneous electrochemical monitoring of a number of physiologically relevant analytes.

2 March 2010 in Expert Opinion on Drug Delivery
Verified
Journal Article
Closed access
SGShaun D Gittard
Shaun D Gittard
AOAleksandr Ovsianikov
Aleksandr Ovsianikov
Boris ChichkovBoris Chichkov
Boris Chichkov
ADAnand Doraiswamy
Anand Doraiswamy
Roger J. NarayanRoger J. Narayan
Roger J. Narayan
Importance of the field: Microneedles are small-scale devices that are finding use for transdermal delivery of protein-based pharmacologic agents and nucleic acid-based pharmacologic agents; howeve...