Flooding in urban areas is counted as a significant disaster that must be correctly mitigated due to the huge amount of affected people, material losses, hampered economic activity, and flood-related diseases. One of the technologies available for disaster mitigation and prevention is satellites providing image data on previously flooded areas. In most cases, floods occur in conjunction with heavy rain. Thus, from a satellite’s optical sensor, the flood area is mostly covered with clouds which indicates ineffective observation. One solution to this problem is to use Synthetic Aperture Radar (SAR) sensors by observing backscatter differences before and after flood events. This research proposes mapping the flood-prone areas using machine learning to classify the areas using the 3D CNN method. The method was applied on a combination of co-polarized and cross-polarized SAR multi-temporal image datasets covering Jakarta City and the coastal area of Bekasi Regency. Testing with multiple combinations of training/testing data proportion split and a different number of epochs gave the optimum performance at an 80/20 split with 150 epochs achieving an overall accuracy of 0.71 after training in 283 min.
Forest and land fires are disasters that greatly impact various sectors. Burned area identification is needed to control forest and land fires. Remote sensing is used as common technology for rapid burned area identification. However, there are not many studies related to the combination of optical and synthetic aperture radar (SAR) remote sensing data for burned area detection. In addition, SAR remote sensing data has the advantage of being a technology that can be used in various weather conditions. This research aims to evaluate the burned area model using a hybrid of convolutional neural network (CNN) as a feature extractor and random forest (CNN-RF) as classifiers on Sentinel-1 and Sentinel-2 data. The experiment uses five test schemes: (1) using optical remote sensing data; (2) using SAR remote sensing data; (3) a combination of optical and SAR data with VH polarization only; (4) a combination of optical and SAR data with VV polarization only; and (5) a combination of optical and SAR data with dual VH and VV polarization. The research was also carried out on the CNN, RF, and neural network (NN) classifiers. On the basis of the overall accuracy on the part of the region of Pulang Pisau Regency and Kapuas Regency, Central Kalimantan, Indonesia, the CNN-RF method provided the best results in the tested schemes, with the highest overall accuracy reaching 97% using Satellite pour l’Observation de la Terre (SPOT) images as reference data. This shows the potential of the CNN-RF method to identify burned areas, mainly in increasing precision value. The estimated result of the burned area at the research site using a hybrid CNN-RF method is 48,824.59 hectares, and the accuracy is 90% compared with MCD64A1 burned area product data.
Although common in developed countries such as Japan and Taiwan, the use of lamps coupled with motion sensors are still uncommon and even rare in Indonesia. Our experiment aims to show that simple installation of commercially available motion sensors can contribute to reduce the electricity bill from the increase of energy efficiency, abundance in availability of energy being the main factor in Indonesian high energy consumption habits. High electricity demand for consumption at current supply level in Indonesia led to the rising cost of electricity bills. This factor is compounded by the fact that many electric generators in Indonesia still use fossil fuels, which contributes to the high basic generation cost. UBL is one of the universities that aim to be a green campus. Our research explores the possibility of installing motion sensors to contribute to the energy efficiency. Although mostly common in developed countries, the use of motion sensors for energy efficiency is still rare, especially in Indonesia. Despite rising cost and supply shortages, Indonesian buildings are still of high energy consumption. Our experiment shows that simple installation of commercially available motion sensors can contribute to reduce the electricity bill from the increase of energy efficiency. One of the efforts to lower energy demand on the consumer side is to use the electricity efficiently, such as turning off lights in a room when it is not in use. This method can be simply done by turning the light switches for office and classrooms, but difficult to do in public spaces such as toilets and corridors. Automatic light switches experimentally installed in sample toilet rooms prove that electricity consumption from the lamps can contribute to the reduction of total weekly energy that translates into Greenhouse Gas emission reduction.
Forest and field fires have become a frequent phenomenon in recent years caused by human activities in Indonesia, affecting all forms of forest and field cover. Forest fire-degraded land is more prone to burn again, due to the nature of peatland in Kalimantan. Rapid mapping technology for burnt areas affected by forest fires is needed to obtain this information. The use of remote sensing technology, in the form of synthetic aperture radar (SAR) images, combined with cloud computing processing speeds up data processing and is not affected by the existing cloud cover. The Quick-Mapping employed in this research provides faster mapping time, compared to the currently employed method, based on field report data, to enable a better and more efficient firefighting effort. The data processing is carried out using cloud computing, enabling the processing of large amounts of data. The processing is carried out starting with importing the data, preprocessing to classification running, simultaneously, using the JavaScript programming language. The research classifies the burnt area from backscatter patterns before and after the event in two measurements, namely the radar burn ratio (RBR) and the radar burn difference (RBD). The RBR is defined as the average backscatter ratio at a certain polarization, while RBD is the difference between the average scattering conditions. The composite image for the classification utilizes images from the RBR and RBD with co-polarized (VV) and cross-polarized (VH) backscatter. The burnt area difference is −1.9 for VH and −1.7 for VV, which indicates a lower backscatter, due to forest fire. The classification of the burnt area yields the best overall accuracy of 88.26% with a support vector machine and processing time of 1 h, compared to the currently 12 h needed to provide burnt area maps from field observation data.
17 December 2024 in IEEE Journal of Selected Topics in Applied Earth Observations and Remote Sensing
Urban flooding significantly impacts populations and often coincides with heavy rainfall, making optical satellite observation challenging due to cloud cover. This study proposes a novel approach using synthetic aperture radar (SAR) sensors, which can penetrate clouds, to classify flooded urban areas. The framework employs a three-dimensional convolutional neural network (3D CNN) to process multi-temporal SAR data from Sentinel-1 (S-1). The dataset included 24 S-1 scenes with Dual VV and VH polarization from March 2019 to February 2020, divided into two co-event images, 18 pre-event images, and four post-event images. The 3D CNN achieved an average overall accuracy of 70.3% and a peak accuracy of 71.8%. These results demonstrate the 3D CNN's potential to accurately estimate flood extent and identify flood-prone areas, supporting early detection and flood prevention in other cities.
The information processing centers including Data Centers in the companies have evolved and the distributed processing of the technologies for servers and network devices elevates the demand of energy and cooling. Therefore, it is important to analyze the environment with more caution, taking into account that the increase in density and variations are aspects that cause changes in the monitoring methodology of the computer environment. Critical threats that can be detected are elevated temperatures, humidity and unauthorized access, or inappropriate actions by data center staff. In this project, a prototype will be designed and implemented to detect some basic environmental variables such as temperature, pressure, current and humidity, which are vital to controlling within a data center, based on the concepts provided by Internet of Things (IoT). It will also focus on reviewing the current status of the University's data centers to determine if they are energy efficient. It will show the process of the detection system implementation, the components used and network connection for sending the information. This project will serve as a starting point for future development of similar systems, allowing the definition of more variables and serve as a solution for the business sector in the region and the country. In our business environment, there are not many similar developments, at a good cost, that the various entities can execute. It is offering an idea of a system of detection of environmental variables in the data center that is competitive and that represents security and reliability.