Wang Shuo

Dr. Wang Shuo

orcid

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 April 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
WSWang Shuo
Wang Shuo
WSWeili Shi
Weili Shi
SYShuai Yang
Shuai Yang
JCJiahao Cui
Jiahao Cui
QGQinwei Guo
Qinwei Guo
Accurate femoral tunnel positioning is crucial for successful anterior cruciate ligament reconstruction (ACLR), yet traditional arthroscopic techniques face significant challenges in spatial orientation and precise anatomical localization. This study presents a novel marker-less computer-assisted navigation system that integrates three-dimensional femoral modeling with real-time arthroscopic guidance. The system employs advanced image processing techniques for accurate condyle segmentation and implements the Bernard and Hertel (BH) grid system for standardized positioning. A curvature-based feature extraction approach precisely identifies the capsular line reference (CLR) on the lateral condyle surface, forming the foundation for establishing the BH reference grid. The system’s two-stage registration framework, combining SIFT-ICP algorithms, achieves accurate alignment between preoperative models and arthroscopic views. Validation results from expert surgeons demonstrated high precision, with 71.5% of test groups achieving acceptable or excellent performance standards (mean deviation distances: 1.12–1.86 mm). Unlike existing navigation solutions, our system maintains standard surgical workflow without requiring additional surgical instruments or markers, offering an efficient and minimally invasive approach to enhance ACLR precision. This innovation bridges the gap between preoperative planning and intraoperative execution, potentially improving surgical outcomes through standardized tunnel positioning.

13 March 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
WSWang Shuo
Wang Shuo
TRTong Ren
Tong Ren
NCNan Cheng
Nan Cheng
RWRong Wang
Rong Wang
LZLi Zhang
Li Zhang
Coronary heart disease, a leading global cause of mortality, has witnessed significant advancement through robotic coronary artery bypass grafting (CABG), with the internal mammary artery (IMA) emerging as the preferred “golden conduit” for its exceptional long-term patency. Despite these advances, robotic-assisted IMA harvesting remains challenging due to the absence of force feedback, complex surgical maneuvers, and proximity to the beating heart. This study introduces a novel virtual simulation platform for robotic IMA harvesting that integrates dynamic anatomical modeling and real-time haptic feedback. By incorporating a dynamic cardiac model into the surgical scene, our system precisely simulates the impact of cardiac pulsation on thoracic cavity operations. The platform features high-fidelity representations of thoracic anatomy and soft tissue deformation, underpinned by a comprehensive biomechanical framework encompassing fascia, adipose tissue, and vascular structures. Our key innovations include a topology-preserving cutting algorithm, a bidirectional tissue coupling mechanism, and dual-channel haptic feedback for electrocautery simulation. Quantitative assessment using our newly proposed Spatial Asymmetry Index (SAI) demonstrated significant behavioral adaptations to cardiac motion, with dynamic scenarios yielding superior SAI values compared to static conditions. These results validate the platform’s potential as an anatomically accurate, interactive, and computationally efficient solution for enhancing surgical skill acquisition in complex cardiac procedures.

22 February 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
TRTong Ren
Tong Ren
WSWang Shuo
Wang Shuo
NCNan Cheng
Nan Cheng
ZFZekun Feng
Zekun Feng
MLMenglu Li
Menglu Li
RWRong Wang
Rong Wang
Objective: Pericardial adhesions can unexpectedly occur prior to cardiac surgery or catheter ablation, even in patients without known risk factors, potentially increasing procedural risks. This study proposed and validated a novel, quantitative, and noninvasive method for detecting pericardial adhesions using four-dimensional computed tomography (4D CT). Methods: We evaluated preoperative 4D CT datasets from 20 patients undergoing cardiac surgery with and without pericardial adhesions. Our novel approach integrates expert-guided pericardial segmentation, symmetric diffeomorphic registration, and motion disparity analysis. The method quantifies tissue motion differences by computing the displacement fields between the pericardium and epicardial adipose tissue (EAT), with a particular focus on the left anterior descending (LAD) region. Results: Statistical analysis revealed significant differences between adhesion and non-adhesion groups (p < 0.01) using two newly developed metrics: peak ratio (PR) and distribution width index (DWI). Adhesion cases demonstrated characteristic high PR values (>100) with low DWI values (<0.3), while non-adhesion cases showed moderate PR values (0.4). Conclusions: This proof-of-concept study validated a novel quantitative framework for assessing pericardial adhesions using 4D CT imaging and provides an objective and computationally efficient tool for preoperative assessment in clinical settings. These findings suggest the potential clinical utility of this framework in surgical planning and risk assessment.

16 May 2025 in arXiv
Verified
Preprint
Open access
PDF file
WSWang Shuo
Wang Shuo
TRTong Ren
Tong Ren
NCNan Cheng
Nan Cheng
RWRong Wang
Rong Wang
LZLi Zhang
Li Zhang
Background and Objective: Precise preoperative planning and effective physician training for coronary interventions are increasingly important. Despite advances in medical imaging technologies, transforming static or limited dynamic imaging data into comprehensive dynamic cardiac models remains challenging. Existing training systems lack accurate simulation of cardiac physiological dynamics. This study develops a comprehensive dynamic cardiac model research framework based on 4D-CTA, integrating digital twin technology, computer vision, and physical model manufacturing to provide precise, personalized tools for interventional cardiology. Methods: Using 4D-CTA data from a 60-year-old female with three-vessel coronary stenosis, we segmented cardiac chambers and coronary arteries, constructed dynamic models, and implemented skeletal skinning weight computation to simulate vessel deformation across 20 cardiac phases. Transparent vascular physical models were manufactured using medical-grade silicone. We developed cardiac output analysis and virtual angiography systems, implemented guidewire 3D reconstruction using binocular stereo vision, and evaluated the system through angiography validation and CABG training applications. Results: Morphological consistency between virtual and real angiography reached 80.9%. Dice similarity coefficients for guidewire motion ranged from 0.741-0.812, with mean trajectory errors below 1.1 mm. The transparent model demonstrated advantages in CABG training, allowing direct visualization while simulating beating heart challenges. Conclusion: Our patient-specific digital-physical twin approach effectively reproduces both anatomical structures and dynamic characteristics of coronary vasculature, offering a dynamic environment with visual and tactile feedback valuable for education and clinical planning.

24 September 2025 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
WSWang Shuo
Wang Shuo
RLRong Liu
Rong Liu
LZLi Zhang
Li Zhang
Current fractional flow reserve computed tomography (FFRCT) methods use static imaging, potentially missing critical hemodynamic changes during the cardiac cycle. We developed a novel dynamic FFRCT framework using 4D-CTA data to capture temporal coronary dynamics throughout the complete cardiac cycle. Our automated pipeline integrates 4D-CTA processing, temporally weighted geometric modeling, and patient-specific boundary conditions derived from actual flow measurements. Preliminary validation in three patients (four vessels) showed that dynamic FFRCT values (0.720, 0.797, 0.811, and 0.952) closely matched invasive FFR measurements (0.70, 0.78, 0.78, and 0.94) with improved accuracy compared to conventional static methods. The dynamic approach successfully captured physiologically relevant hemodynamic variations, addressing inter-patient variability limitations of standardized approaches. This study establishes the clinical feasibility of dynamic FFRCT computation, potentially improving non-invasive coronary stenosis assessment for clinical decision-making and treatment planning.

1 April 2025 in TechRxiv
Verified
Preprint
Open access
WSWang Shuo
Wang Shuo
TRTong Ren
Tong Ren
NCNan Cheng
Nan Cheng
RWRong Wang
Rong Wang
LZLi Zhang
Li Zhang
Virtual surgical simulation offers promising training for complex procedures like robotic internal mammary artery (IMA) harvesting. Building upon previous work on dynamic virtual simulation with haptic feedback, we present an adaptive human-AI interaction (HAI) framework that dynamically adjusts cardiac pulsation parameters based on surgeon behavior analysis. Our system captures surgical tool movements and performance metrics to create personalized training through dynamic difficulty adjustment, context-aware parameter selection, personalized learning paths, and real-time feedback. In longitudinal single-subject experimental design with an experienced cardiac surgeon, our approach demonstrated significant improvements over static simulations: 28% better spatial precision, 32% faster operation time, and 31% reduced workload (NASA-TLX). This research demonstrates how AI-driven adaptivity complements human expertise in highstakes medical training, creating more effective learning environments than either humanonly or AI-only approaches could provide. Future work will validate these findings across surgeons with varying experience levels.