Mohamed Elsayed

Prof. Dr. Mohamed Elsayed

orcid

Research Focus & Metrics

Academic Career Length

11Years (2016-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 December 2017 in Journal of Chromatographic Science
Verified
Journal Article
Closed access
PDF file
MAMaha M Abdelrahman
Maha M Abdelrahman
Ibrahim NaguibIbrahim Naguib
Ibrahim Naguib
MEMohamed Elsayed
Mohamed Elsayed
HZHala A Zaazaa
Hala A Zaazaa
Two accurate, precise and sensitive high-performance thin layer chromatography (HPTLC) and high-performance liquid chromatography (HPLC) methods were developed for assay of ampicillin (AMP) and dicloxacillin (DX) in the presence of their impurity, 6-aminopenicillanic acid (APA). Method (A) is HPTLC method; using silica gel HPTLC F254 plates as a stationary phase with methanol: chloroform: acetic acid (1:9: 0.2, by volume) as a developing system. All the bands were scanned at 220 nm. Method (B) is reversed phase- HPLC which depended on isocratic elution using C18 column and mobile phase consisting of acetonitrile: water (60:40, v/v), pH adjusted to 4 with orthophosphoric acid, at a flow rate of 1 mL min−1 and ultraviolet detection at 240 nm. The proposed methods were validated as per ICH guidelines and their linearity was evident in the ranges of 0.5–2 μg band−1, 0.4–2 μg band−1 and 0.2–1.2 μg band−1 for method (A) and 5–40 μg mL−1, 5–40 μg mL−1 and 2–16 μg mL−1 for method (B) for AMP, DX and APA, respectively. The proposed methods were successfully used for assay of AMP and DX in pure form and in pharmaceutical formulation where no interference from the excipients was detected.

3 May 2016 in Analytical Chemistry Letters
Verified
Journal Article
Closed access
MAMaha M. Abdelrahman
Maha M. Abdelrahman
Ibrahim NaguibIbrahim Naguib
Ibrahim Naguib
MEMohamed Elsayed
Mohamed Elsayed
HZHala A. Zaazaa
Hala A. Zaazaa
Four simple, specific, accurate and precise spectrophotometric methods are developed for determination of chlorhexidine gluconate (CG) in presence of its impurity and/or degradation product namely; para-chloro-aniline (PCA). Method A is derivative spectrophotometry, where CG is determined by first derivative D1 spectrophotometric method in presence of its degradation product PCA at 272 nm, while PCA is determined in presence of CG by second derivative D2 spectrophotometric method at 248.6 nm. Method B is first derivative of ratio spectra spectrophotometry which allows determination of both CG at 266.8 nm and PCA at 328 nm without interference of each other. Method C is dual wavelength spectrophotometry (DWS), where two wavelengths; 233 and 253 nm for CG and 253.8 and 262 nm for PCA are selected for each component in such a way that the difference in absorbance is zero for the second one. Method D is ratio subtraction and extended ratio subtraction spectrophotometry (EXRS), where CG can be determined by dividing the spectrum of the mixture by divisor concentration of 5 μg mL-1 of PCA, while PCA can be determined by dividing the spectrum of the mixture by divisor concentration of 50 μg mL-1 of CG. The specificity of the developed methods is investigated by analyzing different laboratory prepared mixtures of the CG and PCA. Standard deviation values are less than 1.5 in the assay of raw material and tablets. The four methods were statistically compared to the reported method with no significant difference regarding accuracy and precision; assuring their applicability in quality control analysis of drug product.

4 July 2018 in Beni-Suef University Journal of Basic and Applied Sciences
Verified
Journal Article
Open access
PDF file
AHAmira M. Hegazy
Amira M. Hegazy
RARehab M. Abdelfatah
Rehab M. Abdelfatah
HMHamada M. Mahmoud
Hamada M. Mahmoud
MEMohamed Elsayed
Mohamed Elsayed
Specific spectroscopic techniques were validated for assay of four pesticides applied for cucumber in Egypt; mandipropamid (MAN), metalaxyl (MET), thiophenate methyl (THO) and carbendazim (CAR). First method is derivative method for the quaternary mixture of the studied pesticides; by using the first derivative THO was assayed at 281 nm, while MAN and CAR were assayed using second derivative at 236.4 and 256.2 nm, respectively and MET was assayed using third derivative at 221.6 nm. Second method is double divisor ratio spectrum derivative method that used for assay of MAN at 289 nm and MET at 233.2 nm using a double divisor of 30 μg mL-1 of each of THO and CAR, then both THO and CAR were determined at 259 and 267.4 nm, respectively, using a double divisor of 4 μg mL-1 of each of MAN and MET. The obtained results were within the acceptable range regarding to the Egyptian committee of agricultural recommendations.


1 May 2024 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
AMAbobakr A. Mohamed
Abobakr A. Mohamed
KAKhaled Abdel-Hakam Abbas
Khaled Abdel-Hakam Abbas
HAHani Shaaban Abdelmontaleb
Hani Shaaban Abdelmontaleb
MHMohammed I.A. Hamed
Mohammed I.A. Hamed
IMIslam M. Mostafa
Islam M. Mostafa
MEMohamed Elsayed
Mohamed Elsayed

2 May 2018 in Separation Science Plus
Verified
Journal Article
Closed access
PDF file
RARehab M. Abdelfatah
Rehab M. Abdelfatah
AHAmira M. Hegazy
Amira M. Hegazy
HMHamada M. Mahmoud
Hamada M. Mahmoud
MEMohamed Elsayed
Mohamed Elsayed