Xihui Dou

Xihui Dou

orcid

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 October 2025 in Measurement
Verified
Journal Article
Closed access
XDXihui Dou
Xihui Dou
LFLiu Feng
Liu Feng
SXSupeng Xu
Supeng Xu
SLShaowei Lv
Shaowei Lv
YPYuzhuo Pei
Yuzhuo Pei
WQWei Quan
Wei Quan

11 October 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
JWJiaqi Wu
Jiaqi Wu
LFLiu Feng
Liu Feng
LDLihong Duan
Lihong Duan
HPHaoying Pang
Haoying Pang
XDXihui Dou
Xihui Dou
WQWei Quan
Wei Quan
Bias instability is one of the most critical factors in the performance of a Spin-Exchange Relaxation-Free (SERF) co-magnetometer. Previous studies on the SERF co-magnetometer have shown that fluctuations in pump light power density cause variations in the pumping rate, which in turn affect the system’s bias instability. Building on this, this paper analyzes the steady-state response errors in the SERF co-magnetometer caused by fluctuations in pump light power density. By adjusting the vapor cell temperature, the SERF co-magnetometer can be tuned to a vapor cell operating point where the output signal is insensitive to fluctuations in pump light power density, referred to as the pump light power density fluctuation insensitive point. This effectively suppresses the bias instability caused by fluctuations in pump light power density. The proposed method was experimentally validated, and the results showed good consistency with the model. Using this method, the SERF co-magnetometer can achieve insensitivity to pump light power density fluctuations at a specific operating temperature without the need to adjust the laser wavelength or add additional hardware. This effectively reduces the impact of pump light power density fluctuation on the bias instability of the SERF co-magnetometer. This study proposes a method to enhance the performance of the SERF co-magnetometer, providing valuable reference for quantitative error analysis and practical engineering applications.

28 February 2025 in Photonics
Verified
Journal Article
Open access
PDF file
JWJiaqi Wu
Jiaqi Wu
LFLiu Feng
Liu Feng
LDLihong Duan
Lihong Duan
SLShaowei Lv
Shaowei Lv
XDXihui Dou
Xihui Dou
WQWei Quan
Wei Quan
Bias instability is one of the most critical factors in the performance of spin-exchange relaxation-free (SERF) co-magnetometers. Previous studies on SERF co-magnetometers have shown that changes in the atomic ensemble temperature can lead to variations in the alkali metal atom density, which in turn affect the optical rotation angle and light shift, ultimately influencing the system’s stability. Building on this understanding, this paper introduces the thermoelectric analogy method for the first time in the transient heat transfer analysis of SERF co-magnetometer atomic ensembles. Using this method, the primary factors affecting the atomic ensemble temperature in a SERF co-magnetometer were analyzed, and transient heat transfer models were established for the following processes: the interaction between the non-magnetic electric heating system and the atomic ensemble temperature, laser heating of the atomic ensemble by the optical system, and the effect of environmental temperature changes on the non-magnetic electric heating system. These models were experimentally validated through active temperature variation experiments. The experimental results show that the proposed transient heat transfer models accurately describe the related heat transfer processes of the atomic ensemble, with model fitting accuracy exceeding 98%. This lays a solid foundation for the high-precision closed-loop control of the atomic ensemble temperature in SERF co-magnetometers and provides valuable insights for the structural design and engineering applications of SERF co-magnetometers.

14 April 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
YPYuzhuo Pei
Yuzhuo Pei
LFLiu Feng
Liu Feng
ZWZhihong Wu
Zhihong Wu
XDXihui Dou
Xihui Dou
SLShaowei Lv
Shaowei Lv
WQWei Quan
Wei Quan
Quantum sensing technology holds important significance in the forefront of explorations in magnetic field measurement, physics research, and inertial navigation. In optically pumped atomic sensors, laser power stability is essential for maintaining high sensitivity and long-term measurement stability. A major source of power instability is the fluctuation of the polarization direction, which is converted into power noise by polarization-sensitive optical devices, such as polarization beam splitter (PBS). In this work, a compact and high-stability laser power stabilization system for atomic comagnetometers is proposed based on a polarization-direction-insensitive Pancharatnam-Berry phase grating (PDIG). By means of the mentioned PDIG, polarization and power errors induced by fluctuations in the polarization direction are effectively suppressed, and the overall system stability is significantly improved. Experimental results show that, over a continuous 10 hours operation period, the optical power stability is improved by 43.4% compared with that of the conventional PBS-based power-stabilization system. In addition, polarization conversion and beam splitting are integrated into a single device by the PDIG, so that the conventional PBS and quarter-wave plate are replaced, enabling a more compact optical configuration. Further experimental tests performed on a compact atomic comagnetometer incorporating the proposed PDIG-based stabilization scheme demonstrate that, under otherwise identical experimental conditions, the long-term stability is improved by 29.8% compared with the conventional system. A promising route is therefore provided toward highly stable and miniaturized atomic comagnetometer systems for frontier physics exploration and inertial navigation applications.

29 April 2026 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
JMJialu Meng
Jialu Meng
LFLiu Feng
Liu Feng
ZWZhihong Wu
Zhihong Wu
XDXihui Dou
Xihui Dou
SLShaowei Lv
Shaowei Lv
YZYueyang Zhai
Yueyang Zhai
In the field of quantum precision measurement, atomic devices based on the spin-exchange relaxation-free (SERF) effect are of growing interest due to their extremely high sensitivity and potential for miniaturization. As the core component for magnetic field generation and control, the coil system plays a critical role in determining field accuracy and instrument stability. With increasing demands for precision and compact design, magnetic coupling between the field and the shielding structure, as well as modulation field crosstalk among multi-sensor systems, have become major factors limiting SERF instrument performance. To overcome the low attenuation efficiency and poor field uniformity of conventional single layer shielding structures, this paper analyzes the design process of self-shielded coils and evaluates the influence of key parameters on magnetic field characteristics. A dual layer biplanar self-shielded coil model is established, and an inverse design method combining the target field method (TFM) with the tornado optimizer with Coriolis force (TOC) is proposed. The method achieves attenuation of external magnetic fields and high uniformity within the sensing region. Simulation results show that the proposed Bx coil improves field uniformity by 54.46% and reduces the attenuation radius by 57.33% compared to conventional optically pumped magnetometers (OPMs) square coils. The accuracy and effectiveness of the simulation were verified through experiments. The proposed design effectively mitigates magnetic crosstalk in array type and multi-sensor systems, offering strong potential for multichannel SERF magnetometers and other high precision quantum measurement applications.

11 June 2026 in Measurement
Verified
Journal Article
Closed access
YPYuzhuo Pei
Yuzhuo Pei
LFLiu Feng
Liu Feng
ZWZhihong Wu
Zhihong Wu
XDXihui Dou
Xihui Dou
SLShaowei Lv
Shaowei Lv
WQWei Quan
Wei Quan