Tatiana Pereira Filgueiras

Dr. Tatiana Pereira Filgueiras


Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 April 2012
Verified
Conference Paper
Closed access
TFTatiana Pereira Filgueiras
Tatiana Pereira Filgueiras
LLLau Cheuk Lung
Lau Cheuk Lung
LRLuciana de Oliveira Rech
Luciana de Oliveira Rech
For a mobile agent with a time restriction to accomplish its mission, it is necessary for it to meet a deadline. However, in a distributed system there is the possibility of concurrency for the same resource. Treating such competition adequately is very important, especially in a real-time application scenario. In this article, we adopt an execution model in which mobile agents compete for the same resource in the same host. The goal of this paper is to propose a middleware extension that allows concurrent mobile agents to achieve their missions, providing a real-time scheduling mechanism in the JADE platform.

2 July 2025 in Micromachines
Verified
Journal Article
Open access
PDF file
TFTatiana Pereira Filgueiras
Tatiana Pereira Filgueiras
Pedro Bertemes-FilhoPedro Bertemes-Filho
Pedro Bertemes-Filho
FNFabrício Noveletto
Fabrício Noveletto
This study evaluates the accuracy of a low-cost wearable system for the continuous monitoring of vital signs, including heart rate, blood oxygen saturation (SpO2), blood pressure trend (BPT), and body temperature. The prototype was built using the nRF52840 microcontroller, which integrates photoplethysmography and infrared sensors. The heart rate and SpO2 data were collected under three body positions (Rest, Sitting, and Standing), while all measurements were performed using both anatomical configurations: BPT-Finger and BPT-Earlobe. Results were compared against validated commercial devices: UT-100 for heart rate and SpO2, G-TECH LA800 for blood pressure, and G-TECH THGTSC3 for body temperature. Ten participants were monitored over a ten-day period. Bland–Altman analysis revealed clinically acceptable agreement thresholds of ±5 mmHg for blood pressure, ±5–10 bpm for heart rate, ±4% for SpO2, and ±0.5 °C for temperature. Both wearable configurations demonstrated clinically acceptable agreement across all vital signs. The BPT-Earlobe configuration exhibited superior stability and lower variability in the Rest and Sitting positions, likely due to reduced motion artifacts. Conversely, the BPT-Finger configuration showed higher SpO2 accuracy in the Standing position, with narrower limits of agreement. These findings highlight the importance of sensor placement in maintaining measurement consistency across physiological conditions. With an estimated cost of only ~USD 130—compared to ~USD 590 for the commercial alternatives—the proposed system presents a cost-effective, scalable, and accessible solution for decentralized health monitoring, particularly in underserved or remote environments.

23 October 2018 in Concurrency and Computation: Practice and Experience
Verified
Journal Article
Closed access
PDF file
TFTatiana Pereira Filgueiras
Tatiana Pereira Filgueiras
LRLeonardo M. Rodrigues
Leonardo M. Rodrigues
LRLuciana de Oliveira Rech
Luciana de Oliveira Rech
LSLuciana Moreira Sá de Souza
Luciana Moreira Sá de Souza
HNHylson Vescovi Netto
Hylson Vescovi Netto