Diego A. Galarza

Prof. Dr. Diego A. Galarza

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2019 in Cryobiology
Verified
Journal Article
Open access
DGDiego A. Galarza
Diego A. Galarza
ALAntonio López-Sebastián
Antonio López-Sebastián
HWHenri Woelders
Henri Woelders
EBElizabeth Blesbois
Elizabeth Blesbois
JSJulián Santiago-Moreno
Julián Santiago-Moreno
The present study compares a protocol that mimics freezing of ram semen in static nitrogen vapor with two protocols with an initial low cooling rate in the first step, followed by higher cooling rates where ice nucleation occurs. Semen ejaculates, obtained from twelve adults rams, were diluted with TEST-based extender and frozen with either Protocol 1 (three-step decelerating cooling): from +5 °C to -35 °C (40 °C/min), from -35 °C to -65 °C (17 °C/min), and then from -65 °C to -85 °C (3 °C/min); or Protocol 2 (three-step accelerating cooling): from +5 °C to -5 °C (4 °C/min), from -5 °C to -110 °C (25 °C/min), and then from -110 °C to -140 °C (35 °C/min); or Protocol 3 (two-step accelerating cooling), from +5 °C to -10 °C (5 °C/min), and then from -10 °C to -130 °C (60 °C/min). Post-thaw sperm quality was reduced for all protocols (p < .05) compared with fresh semen. Post-thaw percentages of sperm motility characteristics and sperm with intact plasma membrane, intact acrosome, and intact mitochondrial membrane were greater using Protocol 3 than Protocol 2 (p < .05) and Protocol 1 (p < .01). In addition, the post-thaw percentage of sperm with fragmented DNA was lower (p < .05) using Protocol 3 compared with Protocol 1. The present results indicate that a cooling rate of 60 °C/min around and after the time point of ice nucleation provided better post thaw survival and function of ram sperm than lower (and/or decelerating) cooling rates.

1 May 2018 in Animal Reproduction Science
Verified
Journal Article
Closed access
DGDiego A. Galarza
Diego A. Galarza
ALA. López-Sebastián
A. López-Sebastián
HWH. Woelders
H. Woelders
EBE. Blesbois
E. Blesbois
JSJulián Santiago-Moreno
Julián Santiago-Moreno

22 May 2020 in Tropical Animal Health and Production
Verified
Journal Article
Closed access
PDF file
BEByron M. Escandón
Byron M. Escandón
JEJuan S. Espinoza
Juan S. Espinoza
FPFernando P. Perea
Fernando P. Perea
FQFernando Quito
Fernando Quito
RORafael Ochoa
Rafael Ochoa
JGJuan Pablo Garzón
Juan Pablo Garzón

20 April 2020 in Reproduction in Domestic Animals
Verified
Journal Article
Closed access
PDF file
DGDiego A. Galarza
Diego A. Galarza
ALAntonio López‐Sebastián
Antonio López‐Sebastián
JSJulián Santiago-Moreno
Julián Santiago-Moreno

1 December 2021 in Cryobiology
Verified
Journal Article
Closed access
DGDiego A. Galarza
Diego A. Galarza
GLGabriela Landi
Gabriela Landi
EMEdisson Mejía
Edisson Mejía
JSJorge Xavier Samaniego
Jorge Xavier Samaniego
SMSilvana Méndez
Silvana Méndez
JSJulián Santiago-Moreno
Julián Santiago-Moreno

1 July 2019 in Theriogenology
Verified
Journal Article
Open access
DGDiego A. Galarza
Diego A. Galarza
MGM. Ladrón de Guevara
M. Ladrón de Guevara
PBP. Beltrán-Breña
P. Beltrán-Breña
MCMaría Jesús Sánchez Calabuig
María Jesús Sánchez Calabuig
DRDimitrios Rizos
Dimitrios Rizos
JSJulián Santiago-Moreno
Julián Santiago-Moreno
The poor fertility of ram semen stored chilled for long periods has encouraged the development of protocols designed to improve the kinetic vigour and cervical barrier-crossing capacity of sperm. The present work evaluated the effect of sperm selection with Sephadex filtration and the supplementation of 2% glycerol (GLY) to extenders based on ultra-heat-treated skimmed milk (UHT) or Tris-Tes-Glucose (TEST) on ram sperm kinetic parameters, plasma membrane integrity, acrosome integrity, mitochondrial function and fertilizing ability, over long chilling times. The results showed that for non-filtered semen, values for progressive sperm motility (%PSM), straight line velocity (VSL, μm/s) and the percentage of sperm with an intact plasma membrane/intact acrosome/a high mitochondrial function index (%IPIAHM) at all times up to 96 h of chilling were higher when the UHT extender (P < 0.01) was used compared to TEST extender irrespective of the presence of GLY. When semen was previously filtered with Sephadex, the addition of GLY to the UHT extender improved total motility (%TM), the %PSM and the VSL at 96 h compared to all other treatments (P < 0.01). The best results of all were obtained with non-filtered semen and UHT either with or without GLY. Heterologous IVF using zona-intact bovine oocytes was used to assess the fertilizing capacity of non-filtered fresh (FS0), chilled-for-24 h (CS24) or chilled-for-48 h (CS48) ram semen diluted in UHT extender (GLY-free). Heterologous IVF showed that ram sperm, either FS0, CS24 or CS48, were equally capable of penetrating zona pellucida intact bovine oocytes, leading to pronuclear formation and hybrid embryo cleavage (46.3 ± 3.2; 48.8 ± 3.2; and 43.3 ± 3.5, respectively). No differences were seen with respect to fresh sperm in terms of sperm binding, penetration, polyspermy, pronucleus formation or cleavage rates (P > 0.05). In conclusion, neither Sephadex filtration nor addition of glycerol provided extra benefits to ram sperm chilled up to 96 h. Chilled, non-filtered sperm extended with UHT without GLY showed better sperm functionality than did similar sperm extended with TEST extenders. Indeed, sperm diluted in UHT extender, maintained fertilizing ability up to 48 h.