Nishant Ravikumar

Dr. Nishant Ravikumar

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 July 2022 in Medical Image Analysis
Verified
Journal Article
Closed access
Xiahai ZhuangXiahai Zhuang
Xiahai Zhuang
JXJiahang Xu
Jiahang Xu
Xinzhe LuoXinzhe Luo
Xinzhe Luo
CCChen Chen
Chen Chen
COCheng Ouyang
Cheng Ouyang
LLLei Li
Lei Li

1 July 2021 in Medical Image Analysis
Verified
Journal Article
Open access
YXYan Xia
Yan Xia
NRNishant Ravikumar
Nishant Ravikumar
JGJohn P. Greenwood
John P. Greenwood
SNStefan Neubauer
Stefan Neubauer
SPSteffen Petersen
Steffen Petersen
Attilio FrangiAttilio Frangi
Attilio Frangi
High-resolution (HR), isotropic cardiac Magnetic Resonance (MR) cine imaging is challenging since it requires long acquisition and patient breath-hold times. Instead, 2D balanced steady-state free precession (SSFP) sequence is widely used in clinical routine. However, it produces highly-anisotropic image stacks, with large through-plane spacing that can hinder subsequent image analysis. To resolve this, we propose a novel, robust adversarial learning super-resolution (SR) algorithm based on conditional generative adversarial nets (GANs), that incorporates a state-of-the-art optical flow component to generate an auxiliary image to guide image synthesis. The approach is designed for real-world clinical scenarios and requires neither multiple low-resolution (LR) scans with multiple views, nor the corresponding HR scans, and is trained in an end-to-end unsupervised transfer learning fashion. The designed framework effectively incorporates visual properties and relevant structures of input images and can synthesise 3D isotropic, anatomically plausible cardiac MR images, consistent with the acquired slices. Experimental results show that the proposed SR method outperforms several state-of-the-art methods both qualitatively and quantitatively. We show that subsequent image analyses including ventricle segmentation, cardiac quantification, and non-rigid registration can benefit from the super-resolved, isotropic cardiac MR images, to produce more accurate quantitative results, without increasing the acquisition time. The average Dice similarity coefficient (DSC) for the left ventricular (LV) cavity and myocardium are 0.95 and 0.81, respectively, between real and synthesised slice segmentation. For non-rigid registration and motion tracking through the cardiac cycle, the proposed method improves the average DSC from 0.75 to 0.86, compared to the original resolution images.

14 December 2020 in Progress in Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
XCXiang Chen
Xiang Chen
ADAndres Diaz-Pinto
Andres Diaz-Pinto
NRNishant Ravikumar
Nishant Ravikumar
Attilio FrangiAttilio Frangi
Attilio Frangi

5 April 2023 in Medical Image Analysis
Verified
Journal Article
Closed access
MLMingyuan Luo
Mingyuan Luo
XYXin Yang
Xin Yang
HWHongzhang Wang
Hongzhang Wang
HDHaoran Dou
Haoran Dou
XHXindi Hu
Xindi Hu
LSLitao Sun
Litao Sun

17 March 2021 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
SVSulaiman Vesal
Sulaiman Vesal
MGMingxuan Gu
Mingxuan Gu
RKRonak Kosti
Ronak Kosti
AMAndreas Maier
Andreas Maier
NRNishant Ravikumar
Nishant Ravikumar
Deep learning models are sensitive to domain shift phenomena. A model trained on images from one domain cannot generalise well when tested on images from a different domain, despite capturing similar anatomical structures. It is mainly because the data distribution between the two domains is different. Moreover, creating annotation for every new modality is a tedious and time-consuming task, which also suffers from high inter- and intra- observer variability. Unsupervised domain adaptation (UDA) methods intend to reduce the gap between source and target domains by leveraging source domain labelled data to generate labels for the target domain. However, current state-of-the-art (SOTA) UDA methods demonstrate degraded performance when there is insufficient data in source and target domains. In this paper, we present a novel UDA method for multi-modal cardiac image segmentation. The proposed method is based on adversarial learning and adapts network features between source and target domain in different spaces. The paper introduces an end-to-end framework that integrates: a) entropy minimization, b) output feature space alignment and c) a novel point-cloud shape adaptation based on the latent features learned by the segmentation model. We validated our method on two cardiac datasets by adapting from the annotated source domain, bSSFP-MRI (balanced Steady-State Free Procession-MRI), to the unannotated target domain, LGE-MRI (Late-gadolinium enhance-MRI), for the multi-sequence dataset; and from MRI (source) to CT (target) for the cross-modality dataset. The results highlighted that by enforcing adversarial learning in different parts of the network, the proposed method delivered promising performance, compared to other SOTA methods.

26 May 2022 in Medical Image Analysis
Verified
Journal Article
Open access
YXYan Xia
Yan Xia
XCXiang Chen
Xiang Chen
NRNishant Ravikumar
Nishant Ravikumar
CKChristopher Kelly
Christopher Kelly
RARahman Attar
Rahman Attar
Attilio FrangiAttilio Frangi
Attilio Frangi
Accurate 3D modelling of cardiac chambers is essential for clinical assessment of cardiac volume and function, including structural, and motion analysis. Furthermore, to study the correlation between cardiac morphology and other patient information within a large population, it is necessary to automatically generate cardiac mesh models of each subject within the population. In this study, we introduce MCSI-Net (Multi-Cue Shape Inference Network), where we embed a statistical shape model inside a convolutional neural network and leverage both phenotypic and demographic information from the cohort to infer subject-specific reconstructions of all four cardiac chambers in 3D. In this way, we leverage the ability of the network to learn the appearance of cardiac chambers in cine cardiac magnetic resonance (CMR) images, and generate plausible 3D cardiac shapes, by constraining the prediction using a shape prior, in the form of the statistical modes of shape variation learned a priori from a subset of the population. This, in turn, enables the network to generalise to samples across the entire population. To the best of our knowledge, this is the first work that uses such an approach for patient-specific cardiac shape generation. MCSI-Net is capable of producing accurate 3D shapes using just a fraction (about 23% to 46%) of the available image data, which is of significant importance to the community as it supports the acceleration of CMR scan acquisitions. Cardiac MR images from the UK Biobank were used to train and validate the proposed method. We also present the results from analysing 40,000 subjects of the UK Biobank at 50 time-frames, totalling two million image volumes. Our model can generate more globally consistent heart shape than that of manual annotations in the presence of inter-slice motion and shows strong agreement with the reference ranges for cardiac structure and function across cardiac ventricles and atria.