Intentional frequency perturbation by recently researched active islanding detection techniques for inverter based distributed generation (DG) define new threshold settings for the frequency relays. This innovation has enabled the modern frequency relays to operate inside the non-detection zone (NDZ) of the conventional frequency relays. However, the effect of such perturbation on the performance of the rate of change of frequency (ROCOF) relays has not been researched so far. This paper evaluates the performance of ROCOF relays under such perturbations for an inverter interfaced DG and proposes an algorithm along with the new threshold settings to enable it work under the NDZ. The proposed algorithm is able to differentiate between an islanding and a non-islanding event. The operating principle of relay is based on low frequency current injection through grid side voltage source converter (VSC) control of doubly fed induction generator (DFIG) and therefore, the relay is defined as “active ROCOF relay”. Simulations are done in MATLAB.
An average absolute frequency deviation value based active islanding detection technique is proposed in this paper. The inverter's classical q-axis current controller is modeled with a continuous periodic reference current of a small value. During the loss of mains, the island's frequency deviates with respect to the variation in the reference current; this is detected by making the use of an average absolute frequency deviation value. In case of a stable island formation, there is a small periodic frequency deviation owing to the small value of the periodic reference current, and the frequency deviation is so small that it falls inside the nondetection zone (NDZ) of the frequency relay. The main advantage of the proposed algorithm is that it detects the stable island formation but without forcing the island to lose its stable operation. In case of nonislanding switching events, which may transiently impose a significant deviation in the frequency, the possibility of false detection is eliminated by reconfirming the occurrence of islanding once it is suspected. The reference current is kept to a small value to limit the degradation of the power quality and the power factor. Computer simulation is done with MATLAB.
Microgrids are gaining attention as an important part of the smart grid, due to their numerous benefits and their ability to operate both in the island mode as well as in the grid connected mode. However, a protection scheme which suits to a microgrid both in the island mode and the grid connected mode of operation is a challenge. The conventional overcurrent protection scheme faces selectivity and sensitivity issues during the grid faults and the microgrid faults, since the fault current level is different in both the cases for the same relay. Various approaches have been implemented in the past to deal with this problem yet the most promising ones are the adaptive protection techniques. The feasibility, reliability and cost benefit issues are some major concerns which are associated with the implementation of the adaptive microgrid protection schemes. This paper presents a critical review of the existing adaptive protection schemes, the technical challenges, if any, and the recent advancement concerning to their suitability to operate in a smart grid scenario.
30 March 2023 in Sustainable Energy Technologies and Assessments
In recent years, indoor positioning system using existing Wi-Fi infrastructure and MEMS sensors have received significant attention. A key requirement for a complete 3-dimensional indoor positioning algorithm is to provide an accurate and robust user floor location estimate in a multi-floor building. In this paper, we propose novel techniques to estimate user floor location based on the received radio signal strengths from Wi-Fi access points in the building. We illustrate its performance advantages through simulations and multiple field test results across typical use case scenarios. We further discuss Wi-Fi outage scenarios during which the performance of the Wi-Fi based floor determination algorithm is limited. We then propose a method to blend the Wi-Fi access points based floor estimate with pressure sensor measurements to enhance the overall performance of the algorithm. Finally, we present performance results from field tests to validate the efficacy and robustness of our proposed techniques.