Paul Torres

Mrs. Paul Torres

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2023 in Polymers
Verified
Journal Article
Open access
PDF file
FMFreddy Patricio Moncayo-Matute
Freddy Patricio Moncayo-Matute
EVEfrén Vázquez-Silva
Efrén Vázquez-Silva
PPPablo G. Peña-Tapia
Pablo G. Peña-Tapia
PTPaul Torres
Paul Torres
DMDiana Patricia Moya-Loaiza
Diana Patricia Moya-Loaiza
TVTony J. Viloria-Ávila
Tony J. Viloria-Ávila
This article reports on a patient who required a cranial protection system. Using additive manufacturing techniques and surgical planning with the help of bio-models, a patient-specific bone implant solution was proposed that allows aesthetic restoration of the affected area and provides an adequate level of protection. In addition, through a comparative analysis with finite elements, the mechanical response to external actions of the medical device, printed with two materials: polymethylmethacrylate (PMMA) and polyether-ether-ketone (PEEK), is simulated. The tested materials have recognized biocompatibility properties, but their costs on the market differ significantly. The results obtained demonstrate the similarities in the responses of both materials. It offers the possibility that low-income people can access these devices, guaranteeing adequate biomechanical safety, considering that PMMA is a much cheaper material than PEEK.

27 January 2025 in Polymers
Verified
Journal Article
Open access
PDF file
EVEfrén Vázquez-Silva
Efrén Vázquez-Silva
JPJonnathan Andrés Pintado-Pintado
Jonnathan Andrés Pintado-Pintado
FMFreddy Patricio Moncayo-Matute
Freddy Patricio Moncayo-Matute
PTPaul Torres
Paul Torres
DMDiana Patricia Moya-Loaiza
Diana Patricia Moya-Loaiza
In the present investigation, the mechanical properties of natural polyether-ether-ketone (PEEK), processed by additive manufacturing applying fused deposition modeling (FDM) with three different infill densities, are investigated. Mechanical characterization was performed through destructive testing. Specimens were designed in CAD software and printed with controlled infill densities of 40%, 70%, and 100%, using a rectilinear pattern. The results showed that increased infill density improves mechanical strength and stiffness but reduces ductility and energy absorption capacity. For considered infill densities, maximum stress levels reach values of 107.53±6.29MPa, 114.32±11.95MPa, and 63.96±2.39MPa, respectively, against compression, bending, and tensile loading. These findings offer crucial information for optimizing infill density in manufacturing high-strength components for industrial and biomedical applications. As a result, practical guidelines are provided for the design of medical devices, such as implants, achieving an appropriate balance between mechanical performance and material efficiency.

Verified
Journal Article
Open access
PDF file
FMFreddy Patricio Moncayo-Matute
Freddy Patricio Moncayo-Matute
JAJHONATAN HERIBERTO VAZQUEZ ALBORNOZ
JHONATAN HERIBERTO VAZQUEZ ALBORNOZ
EVEfrén Vázquez-Silva
Efrén Vázquez-Silva
ABAna Julia Hidalgo Bravo
Ana Julia Hidalgo Bravo
PTPaul Torres
Paul Torres
DMDiana Patricia Moya-Loaiza
Diana Patricia Moya-Loaiza
Background/Objectives: The application of additive manufacturing in medicine, and specifically in personalised medicine, has achieved notable development. This article aims to present the results and benefits of applying a comprehensive methodology to simulate, plan, and manufacture customised three-dimensional medical prosthetic devices for use in surgery to restore bone structures with congenital and acquired malformations. Methods: To digitally reconstruct a bone structure in three dimensions from a medical image, a segmentation process is developed to correlate the anatomical model. Then, this model is filtered using a post-processing step to generate stereolithography (STL) files, which are rendered using specialised software. The segmentation of tomographic images is achieved by the specific intensity selection, facilitating the analysis of compact and soft tissues within the anatomical region of interest. With the help of a thresholding algorithm, a three-dimensional digital model of the anatomical structure is obtained, ready for printing the required structure. Results: The described cases demonstrate that the use of anatomical test models, cutting guides, and customised prostheses reduces surgical time and hospital stay, and achieves better aesthetic and functional results. Using materials such as polylactic acid (PLA) for presurgical models, appropriate resins for cutting guides, and biocompatible materials such as polyether ether ketone (PEEK) or polymethylmethacrylate (PMMA) for prostheses, the described improvements are achieved. Conclusions: The achievements attained demonstrate the feasibility of applying these techniques, their advantages and their accessibility in Ecuador. They also reinforce the ideas of personalised medicine in the search for medical treatments and procedures tailored to the needs of each patient.

25 July 2024 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FMFreddy Patricio Moncayo-Matute
Freddy Patricio Moncayo-Matute
DCDiego Fernando Chicaiza
Diego Fernando Chicaiza
IVIsrael Santiago Vélez-Sisalima
Israel Santiago Vélez-Sisalima
PTPaul Torres
Paul Torres
EVEfrén Vázquez-Silva
Efrén Vázquez-Silva
The present study analyzes the behavior of connections with flange-web welded plates using the finite element method in tubular columns filled with concrete, and beam, type I. An analytical study of the structural dynamic behavior of a Special Moment Frame (SMF) was carried out, in 5 levels, with HEB structural profiles, for IPE-type columns and beams, according to the requirements established by the AISC-360-16, ANSI-341 standards, and the Ecuadorian standard NEC-2015. The design process of the special frame structure was validated with the help of specialized software. Subsequently, the structural profiles were replaced following the actual construction situation in Ecuador. 3D models of the structural system and the elements of metallic connections were obtained for evaluation through the analysis of finite elements. These models were subjected to virtual tests according to the AISC 341-16 protocols and FEMA 350 standards. The evaluation of the connections showed that they did not meet the flexural strength criterion at 0.04 rad, but they exceeded 80% of the plastic moment at 0.02 rad. Thus, flange-web welded plate connections can be valid for intermediate moment frames (IMF) in areas with moderate seismicity. In addition, it was observed that the columns filled with concrete optimize the structural elements in terms of dimensions; but do not contribute significantly to soldered connections due to the later development of plastic ball joints.

16 October 2025 in Applied Sciences
Verified
Journal Article
Open access
PDF file
FMFreddy Patricio Moncayo-Matute
Freddy Patricio Moncayo-Matute
RCRafael Claramunt
Rafael Claramunt
AGAlvaro Guzman-Bautista
Alvaro Guzman-Bautista
PTPaul Torres
Paul Torres
ETEnrique Chacon Tanarro
Enrique Chacon Tanarro
Background/Objectives: Screw loosening and vertebral fractures remain common after vertebral body tethering (VBT). Because tightening torque sets screw preload, its biomechanical effect warrants explicit modeling. In this paper, a Finite Element (FE) model, supported by ex vivo porcine vertebral tests, was developed and validated that incorporates torque-induced pre-tension to quantify vertebral stress, aiming toward customizable VBT planning. Methods: An FE model with pre-tension and axial extraction failure was parameterized using ex vivo tests on five porcine vertebrae. A laterally inserted surgical screw in each specimen was tightened to 5.9±0.80 Nm. Axial extraction produced failure loads of 2.1±0.31 kN. This is also considered in the FE model to validate the failure scenario. Results: Torque alone generated peak von Mises stresses of 16.1±0.86 MPa (cortical bone 1) and 2.1±0.13 MPa (trabecular), lower than prior reports. With added axial load, peaks rose to 141.1±0.70 MPa and 19.7±0.23 MPa, exceeding typical ranges. However, predicted failure agreed with experiments, showing 0.58 mm displacement and a conical displacement distribution around the washer. Conclusions: Modeling torque-induced pre-tension is essential to reproduce realistic stress states and anchor failure in VBT. The framework enables patient-specific assessment (bone geometry/density) to recommend safe tightening torques, potentially reducing screw loosening and early fractures.

1 September 2019 in Ambiente Construído
Verified
Journal Article
Open access
PDF file
EVEfrén Vázquez-Silva
Efrén Vázquez-Silva
FMFranco David Cajas Muñoz
Franco David Cajas Muñoz
MDMarcelo Xavier Asitimbay Deleg
Marcelo Xavier Asitimbay Deleg
PTPaul Torres
Paul Torres
GFGabriela Abad Farfán
Gabriela Abad Farfán
This article presents the results of the comparison between the CFD simulation and temperature measurements, both in the time domain, at a certain point of interest within a specific closed space (cubicle) of the institutional library of the Salesian Polytechnic University (UPS), at its headquarters in the city of Cuenca, Republic of Ecuador. In this specific case, solar radiation is considered as the main heat transfer mechanism, which is why it was considered in the applied simulation method. An acceptable relative error was obtained between the simulated and measured temperature values. During the summer period, the thermal conditions inside the cubicle are not suitable for the comfort of the users. The study developed can constitute a basic tool for possible future research related to the implementation of climate conditioning for the cubicle, the library in general and any other site with similar constructive and operational characteristics.