Wei Pan

Dr. Wei Pan

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
7 July 2022 in Sensors
Verified
Journal Article
Open access
PDF file
XHXianhe Huang
Xianhe Huang
QCQiao Chen
Qiao Chen
WPWei Pan
Wei Pan
YYYao Yao
Yao Yao
A quartz crystal microbalance (QCM) is a typical acoustic transducer that undergoes a frequency shift due to changes in the mass of its surface. Its high sensitivity, robustness, small size design, and digital output have led to its widespread development for application in the fields of chemistry, physics, biology, medicine, and surface science. Mass sensitivity is one of the vital parameters and forms the basis for quantitative analysis using QCMs. This review firstly introduces the importance, definition, calculation, and measuring method of the mass sensitivity and then focuses on reviewing the influence of electrode parameters (including electrode shape, electrode diameter, electrode thickness, electrode material, etc.) on the mass sensitivity distribution of QCMs. Finally, the effect of the operating frequency on the mass sensitivity of QCMs is also analyzed.

21 July 2020 in ACS Omega
Verified
Journal Article
Closed access
QCQiao Chen
Qiao Chen
NFNing-bo Feng
Ning-bo Feng
XHXianhe Huang
Xianhe Huang
YYYao Yao
Yao Yao
YJYing-Rong Jin
Ying-Rong Jin
DLDong Liu
Dong Liu

27 July 2018 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
XHXianhe Huang
Xianhe Huang
WPWei Pan
Wei Pan
JHJian-Guo Hu
Jian-Guo Hu
QBQing-Song Bai
Qing-Song Bai
After the advent of quartz crystal microbalance (QCM) technology, various QCM-based sensing systems have got certain applications in many science and technology fields, and resulted in dramatic progress in these fields. The core advantage of QCM is its high mass sensitivity which leads to high accuracy and low detection limit. For a QCM, the mass sensitivity is determined by the diameter and thickness of the electrode to a certain extent when the frequency of the quartz wafer is already determined. Theoretical approximate calculation reveals that there is an optimum electrode diameter corresponding to the maximum sensitivity. This is different from the traditional opinion that the smaller the electrode, the higher the mass sensitivity. A plating experiment were carried out using 28 QCMs with different electrode diameters, and the experimental results verified the existence of the optimum diameter. This study is helpful to obtain higher mass sensitivity by optimizing electrode parameters.

14 September 2019 in Sensors
Verified
Journal Article
Open access
PDF file
XHXianhe Huang
Xianhe Huang
QCQiao Chen
Qiao Chen
WPWei Pan
Wei Pan
JHJianguo Hu
Jianguo Hu
YYYao Yao
Yao Yao
Mass sensitivity is vital for quartz crystal microbalance (QCM)-based data analysis. The mass sensitivity distribution of QCMs may differ greatly depending on the shapes, thicknesses, sizes, and materials of the metal electrodes. This is not considered by the Sauerbrey equation, and has a large potential to cause errors in QCM-based data analysis. Many previous works have studied the effects of shape, thickness, and size of metal electrodes on mass sensitivity. However, it is necessary to continue to clarify the relationship between the mass sensitivity and the electrode material of the QCM. In this paper, the results of both theoretical calculation and experimental analysis showed that the mass sensitivity of QCMs with gold electrodes is higher than that of the QCMs with silver electrodes, which in turn indicated that the mass sensitivity of QCMs varies with the electrode material. Meanwhile, the results of this study showed that the mass sensitivity of QCMs with different electrode materials is not proportional to the density of the electrode materials. This result suggests that, in order to obtain more accurate results in the practical applications of QCMs, the influence of electrode material on the mass sensitivity of the QCMs must be considered.

14 December 2023 in Nanomaterials
Verified
Journal Article
Open access
PDF file
YLYanqi Li
Yanqi Li
XHXianhe Huang
Xianhe Huang
QCQiao Chen
Qiao Chen
YYYao Yao
Yao Yao
WPWei Pan
Wei Pan
MXenes, as a typical graphene-like material, excels in the realm of humidity sensing owing to its two-dimensional layer structure, high electrical conductivity, tunable chemical properties, hydrophilicity, and large specific surface area. This study proposed a quartz crystal microbalance (QCM) humidity sensor using a nanochitin/Ti3C2Tx MXene composite as a humidity-sensing material. The morphology, nanostructure, and elemental composition of nanochitin, Ti3C2Tx MXene, and nanochitin/Ti3C2Tx MXene composite materials were characterized using transmission electron microscopy, Fourier transform infrared spectroscopy, and X-ray diffraction. Compared to the pure Ti3C2Tx MXene-coated QCM humidity sensor, the nanochitin/Ti3C2Tx MXene-coated QCM humidity sensor exhibited a higher sensitivity (20.54 Hz/%RH) in the humidity range of 11.3% to 97.3%. The nanochitin/Ti3C2Tx Mxene-coated QCM humidity sensor also demonstrated low humidity hysteresis (2.12%RH), very fast response/recovery times (4.4/4.1 s), a high quality factor (37 k), and excellent repeatability and sustained stability over time. Eventually, a bimodal exponential kinetics adsorption model was utilized for the analysis of the response mechanism of the nanochitin/Ti3C2Tx MXene composite material-based QCM humidity sensor. This study provides new ideas for optimizing the moisture-sensitive performance of MXene-based QCM humidity sensors.

8 May 2019 in Sensors
Verified
Journal Article
Open access
PDF file
QCQiao Chen
Qiao Chen
XHXianhe Huang
Xianhe Huang
WPWei Pan
Wei Pan
YXYuan Xu
Yuan Xu
ZFZhichao Fan
Zhichao Fan
Mass sensitivity plays a crucial role in the practical application of quartz crystal microbalances (QCMs)-based quantitative analysis. n-m type QCMs have many applications, so it is necessary to clarify the relationship between the mass sensitivity and the electrode of the n-m type QCM. The performance of gold-plated films with different electrodes was studied by theoretical calculation and experiment. The results show that the mass sensitivity on the surface of the n electrode and the surface of the m electrode are essentially the same. Meanwhile, the mass sensitivity of n-m type QCMs varies with the diameter of the n and m electrodes. When the diameter of the n electrode is close to half the diameter of the m electrode, mass sensitivity is at maximum value. These results are important for the further designs and applications of n-m type QCMs.