Raphael Giraud

Dr. Raphael Giraud

Geneva University Hospitals and Faculty of Medicine, Geneva, Genève, Switzerland
orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2016 in Journal of Thoracic Disease
Verified
Journal Article
Closed access
PDF file
Carlo BanfiCarlo Banfi
Carlo Banfi
MPMatteo Pozzi
Matteo Pozzi
NSNils Siegenthaler
Nils Siegenthaler
MBMarie-Eve Brunner
Marie-Eve Brunner
DTDidier Tassaux
Didier Tassaux
RGRaphael Giraud
Raphael Giraud
The development of extracorporeal membrane oxygenation (ECMO) technology allows a new approach for the intensive care management of acute cardiac and/or respiratory failure in adult patients who are not responsive to conventional treatment. Current ECMO therapies provide a variety of options for the multidisciplinary teams who are involved in the management of these critically ill patients. In this regard, veno-venous ECMO (VV-ECMO) can provide quite complete respiratory support, even if this highly complex technique presents substantial risks, such as bleeding, thromboembolic events and infection. While VV-ECMO circuits usually include the cannulation of two vessels (double cannulation) in its classic configuration, the use of a single cannula is now possible for VV-ECMO support. Recently, experienced centers have employed more advanced approaches by cannulating three vessels (triple cannulation) which follows veno-arterio-venous (VAV) or veno-arterio-pulmonary-arterial cannulation (VAPa). However, ‘triple’ cannulation expands the field of application but increases the complexity of ECMO systems. In the present review, the authors focus on the indications for VV-ECMO, patient assessment prior to cannulation, the role of ultrasound-guided vessel puncture, double lumen single bicaval cannulations, and finally triple cannulation in VV-ECMO.

30 May 2012 in Critical Care
Verified
Journal Article
Open access
PDF file
NKNicholas Kiefer
Nicholas Kiefer
CHChristoph K Hofer
Christoph K Hofer
GMGernot Marx
Gernot Marx
MGMartin Geisen
Martin Geisen
RGRaphael Giraud
Raphael Giraud
SRSteffen Rex
Steffen Rex
Introduction: Transpulmonary thermodilution is used to measure cardiac output (CO), global end-diastolic volume (GEDV) and extravascular lung water (EVLW). A system has been introduced (VolumeView/EV1000™ system, Edwards Lifesciences, Irvine CA, USA) that employs a novel algorithm for the mathematical analysis of the thermodilution curve. Our aim was to evaluate the agreement of this method with the established PiCCO™ method (Pulsion Medical Systems SE, Munich, Germany, clinicaltrials.gov identifier: NCT01405040) Methods: Seventy-two critically ill patients with clinical indication for advanced hemodynamic monitoring were included in this prospective, multicenter, observational study. During a 72-hour observation period, 443 sets of thermodilution measurements were performed with the new system. These measurements were electronically recorded, converted into an analog resistance signal and then re-analyzed by a PiCCO2™ device (Pulsion Medical Systems SE). Results: For CO, GEDV, and EVLW, the systems showed a high correlation (r2 = 0.981, 0.926 and 0.971, respectively), minimal bias (0.2 L/minute, 29.4 ml and 36.8 ml), and a low percentage error (9.7%, 11.5% and 12.2%). Changes in CO, GEDV and EVLW were tracked with a high concordance between the two systems, with a traditional concordance for CO, GEDV, and EVLW of 98.5%, 95.1%, and 97.7% and a polar plot concordance of 100%, 99.8% and 99.8% for CO, GEDV, and EVLW, respectively. Radial limits of agreement for CO, GEDV and EVLW were 0.31 ml/minute, 81 ml and 40 ml, respectively. The precision of GEDV measurements was significantly better using the VolumeView™ algorithm compared to the PiCCO™ algorithm (0.033 (0.03) versus 0.040 (0.03; median (interquartile range), P = 0.000049). Conclusions: For CO, GEDV, and EVLW, the agreement of both the individual measurements as well as measurements of change showed the interchangeability of the two methods. For the VolumeView method, the higher precision may indicate a more robust GEDV algorithm. Trial registration: clinicaltrials.gov NCT01405040.

19 January 2021 in Physiological Reports
Verified
Journal Article
Open access
PDF file
Marc ScheenMarc Scheen
Marc Scheen
RGRaphael Giraud
Raphael Giraud
Karim BendjelidKarim Bendjelid
Karim Bendjelid
A review of the pathophysiological and clinical evidence surrounding the impact of stress hyperglycemia and cardiac glucotoxicity on cardiac physiology.

23 November 2010 in Critical Care
Verified
Journal Article
Open access
Karim BendjelidKarim Bendjelid
Karim Bendjelid
RGRaphael Giraud
Raphael Giraud
NSNils Siegenthaler
Nils Siegenthaler
FMFrederic Michard
Frederic Michard
Introduction: A new system has been developed to assess global end-diastolic volume (GEDV), a volumetric marker of cardiac preload, and extravascular lung water (EVLW) from a transpulmonary thermodilution curve. Our goal was to compare this new system with the system currently in clinical use. Methods: Eleven anesthetized and mechanically ventilated pigs were instrumented with a central venous catheter and a right (PulsioCath; Pulsion, Munich, Germany) and a left (VolumeView™; Edwards Lifesciences, Irvine, CA, USA) thermistor-tipped femoral arterial catheter. The right femoral catheter was used to measure GEDV and EVLW using the PiCCO2™ (Pulsion) method (GEDV1 and EVLW1, respectively). The left femoral catheter was used to measure the same parameters using the new VolumeView™ (Edwards Lifesciences) method (GEDV2 and EVLW2, respectively). Measurements were made during inotropic stimulation (dobutamine), during hypovolemia (bleeding), during hypervolemia (fluid overload), and after inducing acute lung injury (intravenous oleic acid). Results: One hundred and thirty-seven paired measurements were analyzed. GEDV1 and GEDV2 ranged from 701 to 1,629 ml and from 774 to 1,645 ml, respectively. GEDV1 and GEDV2 were closely correlated (r2 = 0.79), with mean bias of -11 ± 80 ml and percentage error of 14%. EVLW1 and EVLW2 ranged from 507 to 2,379 ml and from 495 to 2,222 ml, respectively. EVLW1 and EVLW2 were closely correlated (r2 = 0.97), with mean bias of -5 ± 72 ml and percentage error of 15%. Conclusions: In animals, and over a very wide range of values, a good agreement was found between the new VolumeView™ system and the PiCCO™ system to assess GEDV and EVLW.

1 September 2016 in Journal of Thoracic Disease
Verified
Journal Article
Closed access
PDF file
Carlo BanfiCarlo Banfi
Carlo Banfi
MPMatteo Pozzi
Matteo Pozzi
MBMarie-Eve Brunner
Marie-Eve Brunner
FRFabio Rigamonti
Fabio Rigamonti
NMNicolas Murith
Nicolas Murith
RGRaphael Giraud
Raphael Giraud
Veno-arterial extracorporeal membrane oxygenation (VA-ECMO) has known a widespread application over the last decade and is now an effective and valuable therapeutic option in refractory cardiogenic shock of various etiologies. In this subgroup of critically ill and unstable patients in cardiogenic shock, VA-ECMO allows, on the one hand, temporary hemodynamic stabilization with improvement of end-organ function and, on the other hand, gives the time to perform complementary diagnostic exams and to decide the therapeutic strategy in these high-risk candidates for immediate long-term mechanical circulatory support (MCS) implantation. VA-ECMO could also be suggested as a rescue therapeutic option for refractory cardiac arrest. It showed promising results in the specific setting of in-hospital cardiac arrest and survival rates with good neurological outcome are reported between 20% and 40%. Conversely, there are contrasting data in the literature about survival after VA-ECMO for out-of-hospital cardiac arrest, as results are highly dependent on low-flow time. The aim of the present report is to offer an overview of different cannulation techniques of VA-ECMO.

Verified
Journal Article
Open access
PDF file
RGRaphael Giraud
Raphael Giraud
MLMatthieu Laurencet
Matthieu Laurencet
BABenjamin Assouline
Benjamin Assouline
ACAmandine De Charrière
Amandine De Charrière
Carlo BanfiCarlo Banfi
Carlo Banfi
Karim BendjelidKarim Bendjelid
Karim Bendjelid
Introduction: Massive acute pulmonary embolism (MAPE) with obstructive cardiogenic shock is associated with a mortality rate of more than 50%. Venoarterial extracorporeal membrane oxygenation (VA-ECMO) has been increasingly used in refractory cardiogenic shock with very good results. In MAPE, although it is currently recommended as part of initial resuscitation, it is not yet considered a stand-alone therapy. Material and Methods: All patients with MAPE requiring the establishment of VA-ECMO and admitted to our tertiary intensive care unit were analysed over a period of 10 years. The characteristics of these patients, before, during and after ECMO were extracted and analysed. Results: A total of 36 patients were included in the present retrospective study. Overall survival was 64%. In the majority of cases, the haemodynamic and respiratory status of the patient improved significantly within the first 24 h on ECMO. The 30-day survival significantly increased when ECMO was used as stand-alone therapy (odds ratio (OR) 15.58, 95% confidence interval (CI) 2.65–91.57, p = 0.002). Nevertheless, when ECMO was implanted following the failure of thrombolysis, the bleeding complications were major (17 (100%) vs. 1 (5.3%) patients, p < 0.001) and the 30-day mortality increased significantly (OR 0.11, 95% CI 0.022–0.520, p = 0.006). Conclusions: The present retrospective study is certainly one of the most important in terms of the number of patients with MAPE and shock treated with VA-ECMO. This short-term mechanical circulatory support, used as a stand-alone therapy in MAPE, allows for the optimal stabilisation of patients.