Stability metrics are used to quantify a system’s ability to maintain equilibrium under disturbances. We did not identify the proposition of a stability metric using sensitivity analysis within the literature. This work proposes a system stability metric and its application to an electrical repowering system. The methodology for applying the proposed metric comprises: (i) system parameters sensitivity analysis and spider diagram construction, (ii) determining the array containing the line segments inclination angles of each spider diagram curve, and (iii) stability calculation using the array mean and maximum inclination value of a line segment. After simulating the model built for the electrical repowering system and applying the methodology, we obtain results regarding the sensitivity indices and stability values of system inputs relative to their outputs, considering the original system and with reduced parameters. Using the stability study, it was possible to determine different stability categories for the system parameters, which indicates the need for different analysis levels.
29 November 2021 in International Transactions on Electrical Energy Systems
The purpose of this paper is to compare mathematical modeling and practical bench in order to validate the electrical interactions between an induction generator and a synchronous generator. Two generators was connected to a common bus in steady state, subject to non-linear load. The results comparing modeling and bench tests show that the induction generator besides the active power increasing, has a better way for harmonic currents flowing in common bus. It was concluded that the induction generator repowering and attenuates current harmonic components present at the connection point, improving the network voltage profile.
25 June 2017 in Transactions on Environment and Electrical Engineering
The purpose of the present study is to simulate and analyze an isolated full-bridge DC/DC boost converter, for photovoltaic panels, running a modified perturb and observe maximum power point tracking method. The zero voltage switching technique was used in order to minimize the losses of the converter for a wide range of solar operation. The efficiency of the power transfer is higher than 90% for large solar operating points. The panel enhancement due to the maximum power point tracking algorithm is 5.06%.
The purpose of this paper is to compare mathematical modeling and practical bench in order to validate the electrical interactions between an induction generator and a synchronous generator. Two generators was connected to a common bus in steady state, subject to non-linear load. The results comparing modeling and bench tests show that the induction generator besides the active power increasing, has a better way for harmonic currents flowing in common bus. It was concluded that the induction generator repowering and attenuates current harmonic components present at the connection point, improving the network voltage profile.