This paper presents a detailed analysis of the two most well-known hill-climbing maximum power point tracking (MPPT) algorithms: the perturb-and-observe (P&O) and incremental conductance (INC). The purpose of the analysis is to clarify some common misconceptions in the literature regarding these two trackers, therefore helping the selection process for a suitable MPPT for both researchers and industry. The two methods are thoroughly analyzed both from a mathematical and practical implementation point of view. Their mathematical analysis reveals that there is no difference between the two. This has been confirmed by experimental tests according to the EN 50530 standard, resulting in a deviation between their efficiencies of 0.13% in dynamic and as low as 0.02% under static conditions. The results show that despite the common opinion in the literature, the P&O and INC are equivalent.
This work presents the construction of a model for a PV panel using the single-diode five-parameters model, based exclusively on data-sheet parameters. The model takes into account the series and parallel (shunt) resistance of the panel. The equivalent circuit and the basic equations of the PV cell/panel in Standard Test Conditions (STC)1 are shown, as well as the parameters extraction from the data-sheet values. The temperature dependence of the cell dark saturation current is expressed with an alternative formula, which gives better correlation with the datasheet values of the power temperature dependence. Based on these equations, a PV panel model, which is able to predict the panel behavior in different temperature and irradiance conditions, is built and tested.
The main objective of this study is to increase the penetration level of photovoltaic (PV) power production in low-voltage (LV) grids by means of solar inverters with reactive power control capability. This paper underlines weak points of standard reactive power strategies which are already imposed by certain grid codes, and then, the study introduces a new reactive power control method that is based on sensitivity analysis. The sensitivity analysis shows that the same amount of reactive power becomes more effective for grid voltage support if the solar inverter is located at the end of a feeder. Based on this fundamental knowledge, a location-dependent power factor set value can be assigned to each inverter, and the grid voltage support can be achieved with less total reactive power consumption. In order to prevent unnecessary reactive power absorption from the grid during admissible voltage range or to increase reactive power contribution from the inverters that are closest to the transformer during grid overvoltage condition, the proposed method combines two droop functions that are inherited from the standard cos φ(P) and Q(U) strategies. Its performance comparison in terms of grid losses and voltage variation with different reactive power strategies is provided by modeling and simulating a real suburban LV network.
24 June 2008 in IEEE Transactions on Industrial Electronics
This paper presents a high-performance maximum power point tracker (MPPT) optimized for fast cloudy conditions, e.g., rapidly changing irradiation on the photovoltaic panels. The rapidly changing conditions are tracked by an optimized hill-climbing MPPT method called dP-P&O. This algorithm separates the effects of the irradiation change from the effect of the tracker's perturbation and uses this information to optimize the tracking according to the irradiation change. The knowledge of the direction of the irradiation change enables the MPPT to use different optimized tracking schemes for the different cases of increasing, decreasing, or steady irradiance. When the irradiance is changing rapidly this strategy leads to faster and better tracking, while in steady-state conditions it leads to lower oscillations around the MPP. The simulations and experimental results show that the proposed dP-P&O MPPT provides a quick and accurate tracking even in very fast changing environmental conditions.
3 March 2017 in IEEE Transactions on Power Electronics
Lifetime of Photovoltaic (PV) inverters is affected by the installation sites related to different solar irradiance and ambient temperature profiles (also referred to as mission profiles). In fact, the installation site also affects the degradation rate of the PV panels and, thus, long-term energy production and reliability. Prior-art lifetime analysis in PV inverters has not yet investigated the impact of PV panel degradations. This paper, thus, evaluates the lifetime of PV inverters considering panel degradation rates and mission profiles. Evaluations have been carried out on PV systems installed in Denmark and Arizona. The results reveal that the PV panel degradation rate has a considerable impact on the PV inverter lifetime, especially in the hot climate (e.g., Arizona), where the panel degrades at a faster rate. In that case, the PV inverter lifetime prediction can be deviated by 54%, if the impact of PV panel degradations is not taken into account.
30 July 2014 in IEEE Journal of Emerging and Selected Topics in Power Electronics
The total installed capacity of photovoltaic (PV) power, within each year, constantly pressures transmission system operators to continuously upgrade their network codes (NCs) moving their focus to grid stabilization features. The NCs started to demand large-scale PV power plants (LPVPPs) to synthetically inherit frequency support functions from the conventional generation-frequency sensitive mode (FSM) and encourage the use of inertial response (IR) along with a minimum supply of active power reserves (APRs). This paper investigates the impact of LPVPPs supplying mandatory FSM enhanced with high-sensitivity IR over the frequency quality parameters. Moreover, the paper performs a time-domain evaluation combined with a statistical analysis of the generated synthetic frequency. The main purpose is to demonstrate the short-term and midterm benefits brought by the added ancillary services and to prove their need with increased levels of PV penetration. This paper realizes a complete representation of a power system having modeled the generic IEEE 12 bus system evaluated over a real-time digital simulator platform. The power system model is enhanced with an automatic generation control system and subject to a realistic Danish winter load profile to create the synthetic frequency of the grid. LPVPPs with APRs and frequency support functions share part of the control responsibilities and show their contributions for short-term and midterm frequency stability once the penetration level reaches higher levels.