Santosh V. Gandhi

Dr. Santosh V. Gandhi

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 January 2008 in Chromatographia
Verified
Journal Article
Closed access
PDF file
NDNilesh Dhavale
Nilesh Dhavale
SGSantosh V. Gandhi
Santosh V. Gandhi
SSShweta Sabnis
Shweta Sabnis
KBKailash Bothara
Kailash Bothara

1 March 2008 in Spectrochimica Acta Part A: Molecular and Biomolecular Spectroscopy
Verified
Journal Article
Closed access
SSShweta S. Sabnis
Shweta S. Sabnis
NDNilesh D. Dhavale
Nilesh D. Dhavale
VJVijay. Y. Jadhav
Vijay. Y. Jadhav
SGSantosh V. Gandhi
Santosh V. Gandhi

1 December 2009 in JPC – Journal of Planar Chromatography – Modern TLC
Verified
Journal Article
Closed access
SKSayali Kadukar
Sayali Kadukar
SGSantosh V. Gandhi
Santosh V. Gandhi
PRPoonam Ranjane
Poonam Ranjane
SRSandeep Ranher
Sandeep Ranher

1 January 2010 in Journal of Chromatographic Science
Verified
Journal Article
Open access
PDF file
PRPoonam N. Ranjane
Poonam N. Ranjane
SGSantosh V. Gandhi
Santosh V. Gandhi
SKSayali S. Kadukar
Sayali S. Kadukar
KBKailash G. Bothara
Kailash G. Bothara
A new simple high-performance thin layer chromatographic method for determination of cefuroxime axetil and ornidazole in combined tablet dosage form is developed and validated. Cefuroxime axetil is second-generation cephalosporin used to treat or prevent infections that are proven or strongly suspected to be caused by bacteria. Ornidazole is used to cure protozoan infections. The separation is carried out on Merck precoated silica gel aluminium plate 60 F254 using toluene-n-butanol-triethylamine (8.5:2:0.5, v/v/v) as mobile phase. Quantitative determination of drugs is carried out by densitometric scanning of plates at 285 nm. The retention factor for ornidazole and cefuroxime axetil is found to be 0.51 ± 0.007 and 0.67 ± 0.009, respectively. The method is validated with respect to linearity, accuracy, precision, and robustness. Response found to be linear in the concentration range of 100–500 ng/band for both cefuroxime axetil and ornidazole. The method has been successfully applied for the analysis of drugs in pharmaceutical formulation. The % assay is found to be 102.36 ± 0.775 and 101.00 ± 1.192 for cefuroxime axetil and ornidazole, respectively.

1 January 2010 in Journal of the Chilean Chemical Society
Verified
Journal Article
Open access
PDF file
UPU. P Patil
U. P Patil
SGSantosh V. Gandhi
Santosh V. Gandhi
MSM. R Sengar
M. R Sengar
VRV. S Rajmane
V. S Rajmane
A simple, specific, accurate and precise high-performance thin-layer chromatographic method for analysis of Telmisartan and Atorvastatin calcium in fixed dose combination has been developed. The method uses aluminium plates coated with silica gel 60 F254 as stationary phase and toluene: methanol (7: 3, v/v) as mobile phase. Densitometric evaluation of the separated bands was performed at 280 nm. The two drugs were satisfactorily presolved with Rf values 0.50 ± 0.01 and 0.29 ± 0.00 for Telmisartan and Atorvastatin calcium, respectively. The respective cahbration plots were found to be linear over the range 200-1000 and 200-700 ng/band for Telmisartan and Atorvastatin calcium, respectively. This method has been successfully validated and applied for the analysis of drugs in pharmaceutical formulation.

1 January 2018 in Asian Journal of Research in Chemistry
Verified
Journal Article
Closed access
PDF file
SGSantosh V. Gandhi
Santosh V. Gandhi
PSPratidnya S. Sonawane
Pratidnya S. Sonawane
UV spectrophotometry is the simple, precise and accurate method of analysis. Chemometrics are set of statistically improved and verified multicomponent methods for analysis. These methods of analysis were developed using Principle Component Regression (PCR) and Partial Least Square (PLS) to apply and study new technique in project work. The spectra of both drugs were recorded at concentrations within their linear ranges at 2.0–12.0 μg/ml for Cefixime and 5.0–30.0 μg/ml for Cloxacillin. The spectra were recorded in the 220 nm-260 nm wavelength range at wavelength interval of 0.5 nm. International Conference on Harmonization Q2 (R1) (ICH) guidelines were followed to validate the method. The proposed method can be used as alternative analytical tool in quality control of these drugs.