Zong-Ming Li

Prof. Zong-Ming Li

orcid

Research Focus & Metrics

Academic Career Length

26Years (2001-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2005 in Clinical Biomechanics
Verified
Journal Article
Closed access
ZLZong-Ming Li
Zong-Ming Li
LKLaurel Kuxhaus
Laurel Kuxhaus
JFJesse A. Fisk
Jesse A. Fisk
TCThomas H. Christophel
Thomas H. Christophel

1 January 2007 in Journal of Biomechanics
Verified
Journal Article
Closed access
ZLZong-Ming Li
Zong-Ming Li
JTJie Tang
Jie Tang

13 November 2013 in PLOS ONE
Verified
Journal Article
Open access
PDF file
KLKe Li
Ke Li
Raviraj NatarajRaviraj Nataraj
Raviraj Nataraj
TMTamara L Marquardt
Tamara L Marquardt
ZLZong-Ming Li
Zong-Ming Li
The human opposable thumb enables the hand to perform dexterous manipulation of objects, which requires well-coordinated digit force vectors. This study investigated the directional coordination of force vectors generated by the thumb and index finger during precision pinch. Fourteen right-handed, healthy subjects were instructed to exert pinch force on an externally stabilized apparatus with the pulps of the thumb and index finger. Subjects applied forces to follow a force-ramp profile that linearly increased from 0 to 12 N and then decreased to 0 N, at a rate of ±3 N/s. Directional relationships between the thumb and index finger force vectors were quantified using the coordination angle (CA) between the force vectors. Individual force vectors were further analyzed according to their projection angles (PAs) with respect to the pinch surface planes and the shear angles (SAs) within those planes. Results demonstrated that fingertip force directions were dependent on pinch force magnitude, especially at forces below 2 N. Hysteresis was observed in the force-CA relationship for increasing and decreasing forces and fitted with exponential models. The fitted asymptotic values were 156.0±6.6° and 150.8±9.3° for increasing and decreasing force ramps, respectively. The PA of the thumb force vector deviated further from the direction perpendicular to the pinching surface planes than that of the index finger. The SA showed that the index finger force vector deviated in the ulnar-proximal direction, whereas the thumb switched its force between the ulnar-proximal and radial-proximal directions. The findings shed light on the effects of anatomical composition, biomechanical function, and neuromuscular control in coordinating digit forces during precision pinch, and provided insight into the magnitude-dependent force directional control which potentially affects a range of dexterous manipulations.

1 December 2003 in Clinical Biomechanics
Verified
Journal Article
Closed access
ZLZong-Ming Li
Zong-Ming Li
HPH.Jamie Pfaeffle
H.Jamie Pfaeffle
DSDean G Sotereanos
Dean G Sotereanos
RGRobert J Goitz
Robert J Goitz
SWSavio L.-Y Woo
Savio L.-Y Woo

1 October 2010 in Clinical Biomechanics
Verified
Journal Article
Closed access
KXKai-Hua Xiu
Kai-Hua Xiu
JKJoo-Han Kim
Joo-Han Kim
ZLZong-Ming Li
Zong-Ming Li

4 September 2009 in HAND
Verified
Journal Article
Closed access
PDF file
CPCorey A. Pacek
Corey A. Pacek
JTJie Tang
Jie Tang
RGRobert J. Goitz
Robert J. Goitz
RKRobert A. Kaufmann
Robert A. Kaufmann
ZLZong-Ming Li
Zong-Ming Li
Although carpal tunnel release is one of the most commonly performed procedures in the USA, the morphology of the carpal tunnel as determined previously in the literature has been questioned. Previous methodology has been questioned for accuracy by recent studies. The purpose of this study was to perform a morphological analysis of the carpal tunnel and correlate carpal tunnel and hand dimensions. The carpal tunnels of ten cadaveric specimens were emptied of their contents and a silicone cast of the carpal tunnel was then created. This cast was then digitized, and the dimensions of the carpal tunnel were calculated. These dimensions were compared with the measured hand dimensions of the specimens. The width, depth, tilt angle, length, cross-sectional area, and volume of the carpal tunnel were 19.2 ± 1.7 mm, 8.3 ± 0.9 mm, 14.8 ± 7.8°, 12.7 ± 2.5 mm, 134.9 ± 23.6 mm2, and 1,737 ± 542 mm3, respectively. Width, depth, and cross-sectional area did not change significantly along the length of the carpal tunnel, but tilt angle did. The width of the palm strongly correlates with the width of the carpal tunnel. Other dimensional correlations did not reach statistical significance. The carpal tunnel is of uniform dimension along its length. The long axis of the carpal tunnel in cross-section rotates volarly from the radial side of the hand increasingly with distal progression along the carpal tunnel. Based on our analysis of ten cadaveric specimens, the width of the carpal tunnel may be estimated by the width of the palm using the equation: WidthCT = 1:285 +0:236 × Widthpalm.