Manuel Jesús Domínguez-Morales

Prof. Manuel Jesús Domínguez-Morales

Universidad de Sevilla
orcid
Associate Proffessor at Computers and Technology of Architec...

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Luis Muñoz-SaavedraLuis Muñoz-Saavedra
Luis Muñoz-Saavedra
Lourdes Miró-AmaranteLourdes Miró-Amarante
Lourdes Miró-Amarante
Manuel Jesús Domínguez-MoralesManuel Jesús Domínguez-Morales
Manuel Jesús Domínguez-Morales
Augmented reality and virtual reality technologies are increasing in popularity. Augmented reality has thrived to date mainly on mobile applications, with games like Pokémon Go or the new Google Maps utility as some of its ambassadors. On the other hand, virtual reality has been popularized mainly thanks to the videogame industry and cheaper devices. However, what was initially a failure in the industrial field is resurfacing in recent years thanks to the technological improvements in devices and processing hardware. In this work, an in-depth study of the different fields in which augmented and virtual reality have been used has been carried out. This study focuses on conducting a thorough scoping review focused on these new technologies, where the evolution of each of them during the last years in the most important categories and in the countries most involved in these technologies will be analyzed. Finally, we will analyze the future trend of these technologies and the areas in which it is necessary to investigate to further integrate these technologies into society.

22 September 2017 in IEEE Transactions on Biomedical Circuits and Systems
Verified
Journal Article
Closed access
Juan Pedro Dominguez-MoralesJuan Pedro Dominguez-Morales
Juan Pedro Dominguez-Morales
Angel F. Jimenez-FernandezAngel F. Jimenez-Fernandez
Angel F. Jimenez-Fernandez
Manuel Jesús Domínguez-MoralesManuel Jesús Domínguez-Morales
Manuel Jesús Domínguez-Morales
GJGabriel Jimenez-Moreno
Gabriel Jimenez-Moreno
Auscultation is one of the most used techniques for detecting cardiovascular diseases, which is one of the main causes of death in the world. Heart murmurs are the most common abnormal finding when a patient visits the physician for auscultation. These heart sounds can either be innocent, which are harmless, or abnormal, which may be a sign of a more serious heart condition. However, the accuracy rate of primary care physicians and expert cardiologists when auscultating is not good enough to avoid most of both type-I (healthy patients are sent for echocardiogram) and type-II (pathological patients are sent home without medication or treatment) errors made. In this paper, the authors present a novel convolutional neural network based tool for classifying between healthy people and pathological patients using a neuromorphic auditory sensor for FPGA that is able to decompose the audio into frequency bands in real time. For this purpose, different networks have been trained with the heart murmur information contained in heart sound recordings obtained from nine different heart sound databases sourced from multiple research groups. These samples are segmented and preprocessed using the neuromorphic auditory sensor to decompose their audio information into frequency bands and, after that, sonogram images with the same size are generated. These images have been used to train and test different convolutional neural network architectures. The best results have been obtained with a modified version of the AlexNet model, achieving 97% accuracy (specificity: 95.12%, sensitivity: 93.20%, PhysioNet/CinC Challenge 2016 score: 0.9416). This tool could aid cardiologists and primary care physicians in the auscultation process, improving the decision making task and reducing type-I and type-II errors.

5 July 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
JCJavier Civit-Masot
Javier Civit-Masot
Francisco Luna-PerejónFrancisco Luna-Perejón
Francisco Luna-Perejón
Manuel Jesús Domínguez-MoralesManuel Jesús Domínguez-Morales
Manuel Jesús Domínguez-Morales
Anton CivitAnton Civit
Anton Civit
The spread of the SARS-CoV-2 virus has made the COVID-19 disease a worldwide epidemic. The most common tests to identify COVID-19 are invasive, time consuming and limited in resources. Imaging is a non-invasive technique to identify if individuals have symptoms of disease in their lungs. However, the diagnosis by this method needs to be made by a specialist doctor, which limits the mass diagnosis of the population. Image processing tools to support diagnosis reduce the load by ruling out negative cases. Advanced artificial intelligence techniques such as Deep Learning have shown high effectiveness in identifying patterns such as those that can be found in diseased tissue. This study analyzes the effectiveness of a VGG16-based Deep Learning model for the identification of pneumonia and COVID-19 using torso radiographs. Results show a high sensitivity in the identification of COVID-19, around 100%, and with a high degree of specificity, which indicates that it can be used as a screening test. AUCs on ROC curves are greater than 0.9 for all classes considered.

10 July 2020 in IEEE Access
Verified
Journal Article
Open access
JCJavier Civit-Masot
Javier Civit-Masot
Manuel Jesús Domínguez-MoralesManuel Jesús Domínguez-Morales
Manuel Jesús Domínguez-Morales
Saturnino Vicente DíazSaturnino Vicente Díaz
Saturnino Vicente Díaz
Anton CivitAnton Civit
Anton Civit
Glaucoma is a degenerative disease that affects vision, causing damage to the optic nerve that ends in vision loss. The classic techniques to detect it have undergone a great change since the intrusion of machine learning techniques into the processing of eye fundus images. Several works focus on training a convolutional neural network (CNN) by brute force, while others use segmentation and feature extraction techniques to detect glaucoma. In this work, a diagnostic aid tool to detect glaucoma using eye fundus images is developed, trained and tested. It consists of two subsystems that are independently trained and tested, combining their results to improve glaucoma detection. The first subsystem applies machine learning and segmentation techniques to detect optic disc and cup independently, combine them and extract their physical and positional features. The second one applies transfer learning techniques to a pre-trained CNN to detect glaucoma through the analysis of the complete eye fundus images. The results of both systems are combined to discriminate positive cases of glaucoma and improve final detection. The results show that this system achieves a higher classification rate than previous works. The system also provides information on the basis for the proposed diagnosis suggestion that can help the ophthalmologist to accept or modify it.

27 July 2016 in IEEE Transactions on Neural Networks and Learning Systems
Verified
Journal Article
Closed access
Angel F. Jimenez-FernandezAngel F. Jimenez-Fernandez
Angel F. Jimenez-Fernandez
ECElena Cerezuela-Escudero
Elena Cerezuela-Escudero
Lourdes Miró-AmaranteLourdes Miró-Amarante
Lourdes Miró-Amarante
Manuel Jesús Domínguez-MoralesManuel Jesús Domínguez-Morales
Manuel Jesús Domínguez-Morales
Francisco Gomez-RodriguezFrancisco Gomez-Rodriguez
Francisco Gomez-Rodriguez
GJGabriel Jiménez-Moreno
Gabriel Jiménez-Moreno
This paper presents a new architecture, design flow, and field-programmable gate array (FPGA) implementation analysis of a neuromorphic binaural auditory sensor, designed completely in the spike domain. Unlike digital cochleae that decompose audio signals using classical digital signal processing techniques, the model presented in this paper processes information directly encoded as spikes using pulse frequency modulation and provides a set of frequency-decomposed audio information using an address-event representation interface. In this case, a systematic approach to design led to a generic process for building, tuning, and implementing audio frequency decomposers with different features, facilitating synthesis with custom features. This allows researchers to implement their own parameterized neuromorphic auditory systems in a low-cost FPGA in order to study the audio processing and learning activity that takes place in the brain. In this paper, we present a 64-channel binaural neuromorphic auditory system implemented in a Virtex-5 FPGA using a commercial development board. The system was excited with a diverse set of audio signals in order to analyze its response and characterize its features. The neuromorphic auditory system response times and frequencies are reported. The experimental results of the proposed system implementation with 64-channel stereo are: a frequency range between 9.6 Hz and 14.6 kHz (adjustable), a maximum output event rate of 2.19 Mevents/s, a power consumption of 29.7 mW, the slices requirements of 11141, and a system clock frequency of 27 MHz.

7 September 2022 in Computer Methods and Programs in Biomedicine
Verified
Journal Article
Open access
JCJavier Civit-Masot
Javier Civit-Masot
ABAlejandro Bañuls-Beaterio
Alejandro Bañuls-Beaterio
Manuel Jesús Domínguez-MoralesManuel Jesús Domínguez-Morales
Manuel Jesús Domínguez-Morales
MRManuel Rivas-Pérez
Manuel Rivas-Pérez
LMLuis Muñoz-Saavedra
Luis Muñoz-Saavedra
José María Rodríguez CorralJosé María Rodríguez Corral
José María Rodríguez Corral
Lung cancer has the highest mortality rate in the world, twice as high as the second highest. On the other hand, pathologists are overworked and this is detrimental to the time spent on each patient, diagnostic turnaround time, and their success rate. In this work, we design, implement, and evaluate a diagnostic aid system for non-small cell lung cancer detection, using Deep Learning techniques. The classifier developed is based on Artificial Intelligence techniques, obtaining an automatic classification result between healthy, adenocarcinoma and squamous cell carcinoma, given an histopathological image from lung tissue. Moreover, a report module based on Explainable Deep Learning techniques is included and gives the pathologist information about the image's areas used to classify the sample and the confidence of belonging to each class. The results show a system accuracy between 97.11 and 99.69%, depending on the number of classes classified, and a value of the area under ROC curve between 99.77 and 99.94%. The classification results obtain a substantial improvement according to previous works. Thanks to the given report, the time spent by the pathologist and the diagnostic turnaround time can be reduced.