Engin Hüner

Dr. Engin Hüner

orcid

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 August 2020 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
BÇBekir Adem Çakmakçı
Bekir Adem Çakmakçı
EHEngin Hüner
Engin Hüner
In this study, the wind energy potential of the Kırklareli University Kayalı Campus at a height of 100 meters has been evaluated by using statistical distribution methods. The parameters of the distributions were calculated by Moment and Maximum Likelihood (MLE) methods. As a result of the goodness of fit tests, the Rayleigh MLE method was estimated the most suitable model among the statistical distributions examined. According to the annual mean results estimated by applying the Rayleigh MLE method; the scale parameter, the wind speed, the standard deviation, and the power density were found as 7.15 m/s, 6.34 m/s, 3.31 m/s and 322 W / m 2 , respectively. The annual dominant wind direction was determined as the Northeast, (NE) with 1407 hours of blowing. It is suggested that the most suitable turbine for the location is the GE103 model, estimated to generate 7.270 GWh of electrical energy annually.

30 June 2020 in Bulletin Of The Polish Academy Of Sciences-Technical Sciences
Verified
Journal Article
Open access
PDF file
EHEngin Hüner
Engin Hüner
In this study, the optimization of air gap magnetic flux density of open slotted axial flux permanent magnet (AFPM) machine which was developed for wind turbine has been obtained using the Taguchi experimental method. For this, magnetic analyzes were performed by ANSYS Maxwell program according to Taguchi table. Then the optimum values have been determined and the average magnetic flux density values have been calculated for air gap and iron core under load and no-load conditions with ANSYS Maxwell. Traditionally, 15625 analyzes are required for 6 independent variables and 5 levels when experimental method is used. In this study, optimum values are determined by 25 magnetic analyzes, which use L25 orthogonal array. For this purpose, both factor effect graph and signal to noise ratios are used, according to the factors and levels which are obtained from the factor effect graph and the signal to noise ratio. Parameters are re-analyzed by Maxwell. The optimum factors and levels are determined. For optimized values, the air gap magnetic flux density is improved by 65.7% and 173.26%, respectively, according to the average value and the initial design. Therefore, the variables are optimized in a shorter time with Taguchi experimental design method instead of the traditional design method for open slotted AFPM generator. In addition, the results were analyzed statistically using ANOVA and Regression model. The variables were found to be significant by ANOVA. The degree of influence of the variables on the air gap magnetic flux density was also determined by the Regression model.

22 October 2015 in Tehnicki vjesnik - Technical Gazette
Verified
Journal Article
Open access
PDF file
EHEngin Hüner
Engin Hüner
Mustafa Caner AkunerMustafa Caner Akuner
Mustafa Caner Akuner
UDUğur Demir
Uğur Demir
This paper presents a novel approach in design of toroidal axial flux permanent magnet open-slotted NN type (TAFPMOS-NN) motor. TAFPMOS-NN motor is an accomplished both theoretical and experimental model. The results of theoretical works...

4 April 2022 in International Journal of Green Energy
Verified
Journal Article
Closed access
EHEngin Hüner
Engin Hüner
HTHayrettin Toylan
Hayrettin Toylan
In this study, the design parameters of Open Slotted Axial Flux Permanent Magnet (OSAFPM) Generator for wind turbines are presented using Genetic Algorithms (GA), an optimization algorithm based on natural selection and genetic mechanisms. Electromagnetic analysis of Open Slotted Axial Flux Permanent Magnet generator has been performed by using parameters optimized with Genetic Algorithms. The ANSYS Maxwell program, which uses the finite element method (FEM), has been used for electromagnetic analysis. Compared to ANSYS Maxwell, it is observed that the genetic algorithm significantly reduces the computational time required for design optimization. However, initial design and optimization with Genetic Algorithms have resulted by 8.94% increase in power densities. In addition, 12.71%, 38.62%, 62.02%, and 56.39% improvements have been obtained for air gap magnetic flux density, flux linkage, induced voltage, and current waveforms, respectively. This suggests that optimization with a Genetic algorithm improves the Open Slotted Axial Flux Permanent Magnet generator parameters.

1 January 2020 in Progress in Electromagnetics Research C
Verified
Journal Article
Open access
EHEngin Hüner
Engin Hüner
GZGökhan Zeka
Gökhan Zeka

1 September 2021 in Energy Sources, Part A: Recovery, Utilization, and Environmental Effects
Verified
Journal Article
Closed access
EHEngin Hüner
Engin Hüner
AMAykan Mutlu
Aykan Mutlu
Reducing the cogging torque in the axial flux permanent magnet (AFPM) generators is an important study area. Especially, AFPM generators with open slotted and rectangular-shaped poles have high cogging torque and high total harmonic distortion (THD). Generators used in wind turbines require minimal mechanical vibration and a smooth sinusoidal wave. In this study, a new hybrid method is proposed to reduce the cogging torque and increase electrical performance. The proposed method involves combining two techniques to reduce cogging torque, including magnet placement angle and magnet grouping technique. In the proposed hybrid method, the electrical performance of the AFPM generator has improved for the minimum cogging torque. This proposed new method is cost-effective and easy to apply. 3D finite element method (FEM) and experimental verifications were performed for the accuracy of the proposed method. When the results are examined, cogging torque was improved by at least 80% with the new hybrid method. However, the electrical performance has been improved for 10% power loss, and the total harmonic distortion (THD) has been reduced to less than 3%.