Zhihong Li

Dr. Zhihong Li


Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
26 February 2016 in Materials Horizons
Verified
Journal Article
Closed access
PDF file
TYTingting Yang
Tingting Yang
Xinming LiXinming Li
Xinming Li
XJXin Jiang
Xin Jiang
SLShuyuan Lin
Shuyuan Lin
JLJunchao Lao
Junchao Lao
Hongwei ZhuHongwei Zhu
Hongwei Zhu
This work demonstrates that engineering of the connection channels in gold thin films is an effective way to alter its resistivity for improved sensitivity in strain sensors. We investigated the formation of channel cracks and explored the corresponding piezoresistive behavior. The developed strain sensor possessed GFs as high as 200 (ε < 0.5%), 1000 (0.5% < ε < 0.7%), and even greater than 5000 (0.7% < ε < 1%), which are among the highest values reported thus far at such small deformation, and are promising in the applications of electronic skin, wearable sensors and health monitoring platforms.

13 July 2017 in ACS Sensors
Verified
Journal Article
Closed access
TYTingting Yang
Tingting Yang
XJXin Jiang
Xin Jiang
YZYujia Zhong
Yujia Zhong
XZXuanliang Zhao
Xuanliang Zhao
SLShuyuan Lin
Shuyuan Lin
Hongwei ZhuHongwei Zhu
Hongwei Zhu

16 October 2015 in ACS Nano
Verified
Journal Article
Closed access
TYTingting Yang
Tingting Yang
WWWen Wang
Wen Wang
HZHongze Zhang
Hongze Zhang
Xinming LiXinming Li
Xinming Li
JSJidong Shi
Jidong Shi
Hongwei ZhuHongwei Zhu
Hongwei Zhu

14 June 2022 in Nano-Micro Letters
Verified
Journal Article
Open access
PDF file
JLJunshi Li
Junshi Li
YMYundong Ma
Yundong Ma
DHDong Huang
Dong Huang
ZWZhongyan Wang
Zhongyan Wang
ZZZhitong Zhang
Zhitong Zhang
ZLZhihong Li
Zhihong Li
Highlights: Polyimide-based flexible microneedle array (PI-MNA) electrodes realize high electrical/mechanical performance and are compatible with wearable wireless recording systems. The normalized electrode–skin interface impedance (EII) of the PI-MNA electrodes reaches 0.98 kΩ cm2 at 1 kHz and 1.50 kΩ cm2 at 10 Hz, approximately 1/250 of clinical standard electrodes. This is the first report on the clinical study of microneedle electrodes. The PI-MNA electrodes are applied to clinical long-term continuous monitoring for polysomnography. Microneedle array (MNA) electrodes are an effective solution to achieve high-quality surface biopotential recording without the coordination of conductive gel and are thus very suitable for long-term wearable applications. Existing schemes are limited by flexibility, biosafety, and manufacturing costs, which create large barriers for wider applications. Here, we present a novel flexible MNA electrode that can simultaneously achieve flexibility of the substrate to fit a curved body surface, robustness of microneedles to penetrate the skin without fracture, and a simplified process to allow mass production. The compatibility with wearable wireless systems and the short preparation time of the electrodes significantly improves the comfort and convenience of electrophysiological recording. The normalized electrode–skin contact impedance reaches 0.98 kΩ cm2 at 1 kHz and 1.50 kΩ cm2 at 10 Hz, a record low value compared to previous reports and approximately 1/250 of the standard electrodes. The morphology, biosafety, and electrical/mechanical properties are fully characterized, and wearable recordings with a high signal-to-noise ratio and low motion artifacts are realized. The first reported clinical study of microneedle electrodes for surface electrophysiological monitoring was conducted in tens of healthy and sleep-disordered subjects with 44 nights of recording (over 8 h per night), providing substantial evidence that the electrodes can be leveraged to substitute for clinical standard electrodes.

3 October 2018 in Advanced Energy Materials
Verified
Journal Article
Closed access
PDF file
MHMeirong Huang
Meirong Huang
CLChangli Li
Changli Li
LZLi Zhang
Li Zhang
QCQiao Chen
Qiao Chen
ZZZhen Zhen
Zhen Zhen
Hongwei ZhuHongwei Zhu
Hongwei Zhu

1 January 2018 in Theranostics
Verified
Journal Article
Open access
DHDong Huang
Dong Huang
DZDeyao Zhao
Deyao Zhao
XWXiaoxia Wang
Xiaoxia Wang
CLChunhui Li
Chunhui Li
TYTongren Yang
Tongren Yang
ZLZhihong Li
Zhihong Li
Rationale: Delivery of nucleic acid molecules into skin remains a main obstacle for various types of gene therapy or vaccine applications. Here we propose a novel electroporation approach via combined use of a microneedle roller and a flexible interdigitated electroporation array (FIEA) for efficient delivery of DNA and siRNA into mouse skin.