The aim of this paper was to compare the perioperative and postoperative results of photoselective vaporization of the prostate with the GreenLight-XPS 180 Watt System (PVP) and transurethral resection of the prostate (TURP). This retrospective study included 140 men who underwent PVP and 114 men who underwent TURP for symptomatic benign prostate enlargement (BPE) between June 2010 and February 2015. The primary outcome measures were the patient reported outcome, operative results, International Prostate Symptom Score-Quality of Life (IPSS-QoL), complication rates, catheterization time, and length of hospital stay. The median follow-up times were 27 months (range 14–44) for the PVP group and 36 months (range 25–47) for the TURP group. The patient characteristics were well balanced in both groups with a median age of 71 years (PVP group) vs. 70 years (TURP group) and a comparable prostate volume (median 50 mL in the PVP group vs. 45 mL in the TURP group). The IPSS-QoL was significantly higher in the PVP group than in the TURP group (median 22 + 4; range 16–27 + 3−5 vs. median 19 + 3; range 15−23 + 3−4; p = 0.02). Men undergoing PVP were more likely to be on anticoagulants (PVP group n = 23; 16% vs. TURP group n = 2; 2%, p < 0.001). The median operation time (OT; min) for both procedures was comparable with 68 min (PVP group; range 53–91) vs. 67 min (TURP group; range 46–85). The rate of severe intraoperative bleeding was significantly lower in the PVP group than in the TURP group (n = 7; 5% vs. n = 16; 14%; p = 0.01). The postoperative catheterization time and length of hospital stay was significantly lower in the PVP group (median 1–2 days; range 1–4) vs. the TURP group (median 2–4 days; range 2–5; both p < 0.001). Complication rates (Clavien-Dindo classification ≥III) based on the follow-up data showed no statistically significant difference between the PVP group and the TURP group (n = 6; 4% vs. n = 6; 5%; p = 0.28). The IPSS on follow-up showed an equivalent reduction in symptoms for both treatment modalities (IPSS-QoL of 5 + 1; range 2–11 + 0−2 for both). There were no differences concerning urge (PVP group n = 3; 2% vs. TURP group n = 3; 3%; p = 0.90) and men were similarly satisfied with the postoperative outcome (PVP group 92% vs. TURP group 87%; p = 0.43). The PVP group was associated with a shorter hospitalization time and showed a reduced risk of bleeding, despite patients remaining on anticoagulants, without increasing the overall operative time. There was no difference in the patient reported outcome for both procedures.
Purpose: To evaluate changes in global perioperative data of GreenLight-XPS 180-Watt photo-selective vaporization of the prostate (GL-XPS) of the Global Greenlight Group (GGG) database. Methods: 3441 men, who underwent GL-XPS for symptomatic BPH between 2011 and 2019 at seven high volume international centers, were included. Primary outcome measurements were operative time (OT; min), effective laser time (LT; min of OT), as well as intraoperative and postoperative adverse events (AEs), all analyzed by year of surgery (2011–2019) and prostate volume (PV) group (< 80 ml vs. 80-150 ml vs. > 150 ml). Results: The median age was 70 years (interquartile range 64–77), the median PV was 64 ml (IQR 47–90). The OT and LT slightly increased but stayed highly efficient all in all. Median OT was 60 min (IQR 45–83) and LT was 33 min (IQR 23–46). Median energy use was 253 kJ (IQR 170–375) with an energy density of 3.94 kJ/ml (IQR 2.94–5.02). The relative probability of perioperative AEs decreased by 17% each year (p < 0.001). The relative probability of perioperative transfusion dropped significantly from 2% in 2011 to 0% in 2019 (p = 0.007). The early postoperative complications (within 30 days after surgery) decreased significantly from 48.8% (n = 106) in 2011 to 24.7% (n = 20) in 2019 (p > 0.001). Conclusion: These findings from the GGG demonstrate significant improvement secondary to growing experience with GL-XPS between 2011 and 2019 in intraoperative AEs, including transfusions, and postoperative AEs. While staying highly efficient in OT and LT of GL-XPS within a 9-year period of experience.