12 November 2021 in Journal of Cataract & Refractive Surgery
Purpose: To determine the prevalence of anterior vitreous detachment (AVD) in routine bag-in-the-lens (BIL) cataract cases and possibly to identify risk factors for its presence. Setting: University Hospital of Antwerp, Belgium. Design: Prospective cross-sectional study. Methods: Patients having routine BIL cataract surgery were included. Patients with traumatic cataract, previous intraocular surgeries, YAG laser treatment, intravitreal injection, or medical conditions that might affect normal ophthalmologic anatomy were excluded. Several parameters were collected from the patients’ records, and their surgical videos/photographs/optical coherence tomography were evaluated. Results: 99 eyes of 99 patients were included. Detectable AVD was observed in 62 eyes (63%). AVD was not present in 37 eyes (37%). The difference in prevalence of AVD between men and women was not statistically significant (P = .55, Pearson χ2 test). The Mann-Whitney U test for axial length was not statistically significant (P = .38). However, it was statistically significant for age (P < .005). A logistic regression model to ascertain the effect of age on the likelihood that patients had AVD did reach statistical significance (χ2 (1) = 8.246, P < .005). Conclusions: The prevalence of AVD in a routine cataract population was 63%. Age was identified as a risk factor. This study model determined that the odds for AVD increase 5.3% with each year of patient age. These data allowed for better preoperative and postoperative assessment of complications. The BIL, by its mandatory primary posterior continuous curvilinear capsulorhexis, did not increase the risk for postoperative ocular complications in the posterior segment of the eye.
18 October 2021 in Klinische Monatsblätter für Augenheilkunde
GHGöran Darius Hildebrand
Background Subluxation of the crystalline lens in childhood confronts the surgeon with a dilemma: to operate or to wait and see. Surgery is usually not performed when the subluxation is still limited. However, postponing the surgery increases the surgical difficulty as the capsular bag becomes more difficult to use as a means of support for the intraocular lens (IOL). A large number of children already present a pronounced subluxation at first presentation. In this paper, we describe a technique to optimise centration and fixation of the bag-in-the-lens (BIL) IOL in children younger than 7 years of age with congenital ectopia lentis. Methods Between October 2019 and December 2020, we performed lens extraction using a combination of bean-shaped segments to support the BIL IOL and a 6 – 0 polypropylene loop fixated at the sclera, following the Yamane technique, for the purpose of centration. We used this technique for seven eyes of four patients. The patients were between 2 and 6 years old; 3 boys and 1 girl. A definite diagnosis of Marfan syndrome was made for two children; for the other two, there was no proven underlying pathology. The luxation was upwards in all cases. The degree of luxation was severe in all eyes. The preoperative refraction values showed high astigmatism values for all eyes, ranging from 6.5 to 11.25 dioptres. Three out of the four patients were myopic, ranging from − 1.5 to − 9 dioptres. Results The surgery could be performed without major complications in all eyes. Good centration was obtained, which remained stable in the postoperative period. Refraction improved with greatly diminished degrees of astigmatism (ranging from 0.25 to 3 dioptres) and myopia (spheres ranging from − 2 to + 1.75 dioptres). Conclusion Our novel technique incorporated the BIL technique with the addition of bean-shaped segments and a polypropylene 6/0 suture fixated at the sclera. In this way, we were able to obtain good centration and stability of the implanted IOL, as well as a good refractive outcome in all cases.
1 June 2025 in Emerging Infectious Diseases
FGfor the Spiroplasma Infantile Cataract Group
for the Spiroplasma Infantile Cataract Group
+7
We report the phenotype causing infections and options for diagnosis and treatment.
8 January 2025 in Journal of Optometry
The maximum accommodative range is a useful indication of visual function. It decreases with age, but the exact cause of this decrease is not fully understood. It is associated with the increasing rigidity of the lens and changes to the lens shape, as well as the geometry of the zonular attachments. This work aims to determine the relationship between the accommodative range and lens shape in a group of healthy young adults. This study includes 40 emmetropic participants between 20 and 30 years of age. They filled in a questionnaire and underwent accommodation measurements using the RAF Convergence Rule and the Negative Lens Test. After a drop of Tropicamide 0.5 % and Cyclopentolate 1 %, participants underwent measurements with autorefractor, Scheimpflug tomography (Pentacam HR, Oculus), anterior segment Optical Coherence Tomography and optical biometry. The accommodative range did not correlate significantly (p>0.05) with any of the lenticular or ocular parameters considered, such as lens thickness, lens radii of curvature, axial length, or corneal power. The crystalline lens shape does not affect the accommodative range of the eye. This may be due to the smaller deformation required to bring a thicker lens to the same level of accommodation as a thinner lens. The amount of force on the zonular fibres may therefore be similar, in all lenses, regardless of the lens shape.
1 April 2026 in Journal of Cataract & Refractive Surgery
Purpose: To investigate the optimal intraocular lens (IOL) corrections for virtual eyes with moderate to severe keratoconus (KC) using ray tracing and comparative analysis of image quality. Setting: Computer simulations conducted using MATLAB-based custom ray-tracing software. Design: The study included 20 eyes generated from a statistical eye model called SyntEyes, which produces eye biometrics for KC eyes for optical simulation. The visual Strehl ratio (VSX) was used to quantify image quality based on optical wavefront analysis. Methods: The eyes underwent various simulated corrections, including spherical and toric IOLs, as well as spherical and toric rigid gas-permeable (RGP) contact lenses, both individually and in combination. Comparisons were made across different correction strategies. Results: Spherical and toric IOLs alone modestly improved VSX to 0.025 ± 0.004 and 0.034 ± 0.005, respectively, from a baseline of 0.013 ± 0.003 ( P < .001). By contrast, eyes corrected with toric RGP lenses after IOL implantation demonstrated significantly higher image quality: 0.250 ± 0.014 (spherical IOL) and 0.246 ± 0.014 (toric IOL) ( P < .001). However, combining 2 toric elements often led to overcorrection and increased aberrations. Conclusions: IOL corrections alone are insufficient to compensate for large corneal aberrations present in KC eyes. Subsequent fitting with toric RGP lenses can restore most eyes to normal levels of visual image quality. Among the compared IOL corrections, the combination of a spherical IOL with a toric IOL gave the best average VSX on average and avoids chances of overcorrection.
27 August 2022 in American Journal of Ophthalmology Case Reports
To report secondary opacification of a hydrophilic bag-in-the-lens (BIL) which is a rare manifestation that can happen years after initial surgery. We describe a case of a prominent wave-like, rippled opacification on the posterior surface of the BIL. The opacification was composed of calcium deposits and seems to start in the periphery as a ring and progresses to the centre of the posterior surface. Due to the specific design of the BIL, there is direct contact between the BIL and the posterior chamber, both with the space of Berger, and the anterior hyaloid, particularly in this very hyperopic eye. Conclusions and importance: Abnormal fluid flow and stagnation in an unusual retrolenticular space is a possible explanation for this unusual pattern of posterior surface opacification.