Sorcha Ní Dhubhghaill

Prof. Dr. Sorcha Ní Dhubhghaill

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2014 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Closed access
PDF file
SDSorcha Ní Dhubhghaill
Sorcha Ní Dhubhghaill
Jos J. RozemaJos J. Rozema
Jos J. Rozema
SJSien Jongenelen
Sien Jongenelen
IHIrene Ruiz Hidalgo
Irene Ruiz Hidalgo
NZNadia Zakaria
Nadia Zakaria
MTMarie-José Tassignon
Marie-José Tassignon
Purpose. To describe the normative data for corneal Scheimpflug densitometry based on a cohort of normal participants. Methods. A total of 445 healthy participants were recruited for assessment (794 eyes). Left and right eyes were considered separately. All participants were assessed using the corneal densitometry analysis add-on to the standard software of the Oculus Pentacam. Densitometry measurements were obtained and expressed in standardized grayscale units (GSU). Results. All participants were Caucasian; 42% were male and 58% were female. The mean age was 48.0 ± 15.3 years (range, 20.2–84.2 years). Mean corneal densitometry over the 12-mm-diameter area was 19.74 ± 3.89 GSU. When divided by radial zone, densitometry values were lowest in the central zone (16.76 ± 1.87 GSU) and highest in the periphery (27.36 ± 7.47 GSU). There was no difference between central zone and the surrounding 2- to 6-mm annulus (P > 0.05), though the 6- to 10-mm and the 10- to 12-mm zones displayed higher densitometry values (P < 0.001). When divided by depth, the anterior layer displayed the highest densitometry reading of 25.81 ± 5.14 GSU, which was significantly higher than that of both the central (P < 0.001) and the posterior layers (P < 0.001). Changes in corneal densitometry were correlated with age, though not within the central 6-mm-diameter ring. No sex difference was seen within the cohort. Conclusions. This add-on to the standard imaging software allows rapid and objective assessment of the corneal densitometry. We provide normative data that may be used as a reference facilitating research and complementing clinical examination.

14 December 2015 in Stem Cells International
Verified
Journal Article
Open access
PDF file
MHMichel Haagdorens
Michel Haagdorens
SASara Ilse Van Acker
Sara Ilse Van Acker
VGVeerle Van Gerwen
Veerle Van Gerwen
SDSorcha Ní Dhubhghaill
Sorcha Ní Dhubhghaill
CKCarina Koppen
Carina Koppen
NZNadia Zakaria
Nadia Zakaria
Severe ocular surface disease can result in limbal stem cell deficiency (LSCD), a condition leading to decreased visual acuity, photophobia, and ocular pain. To restore the ocular surface in advanced stem cell deficient corneas, an autologous or allogenic limbal stem cell transplantation is performed. In recent years, the risk of secondary LSCD due to removal of large limbal grafts has been significantly reduced by the optimization of cultivated limbal epithelial transplantation (CLET). Despite the great successes of CLET, there still is room for improvement as overall success rate is 70% and visual acuity often remains suboptimal after successful transplantation. Simple limbal epithelial transplantation reports higher success rates but has not been performed in as many patients yet. This review focuses on limbal epithelial stem cells and the pathophysiology of LSCD. State‐of‐the‐art therapeutic management of LSCD is described, and new and evolving techniques in ocular surface regeneration are being discussed, in particular, advantages and disadvantages of alternative cell scaffolds and cell sources for cell based ocular surface reconstruction.

1 March 2018 in Acta Biomaterialia
Verified
Journal Article
Open access
SMSteffi Matthyssen
Steffi Matthyssen
BBBert Van Den Bogerd
Bert Van Den Bogerd
SDSorcha Ní Dhubhghaill
Sorcha Ní Dhubhghaill
CKCarina Koppen
Carina Koppen
NZNadia Zakaria
Nadia Zakaria
Corneal blindness is traditionally treated by transplantation of a donor cornea, or in severe cases by implantation of an artificial cornea or keratoprosthesis. Due to severe donor shortages and the risks of complications that come with artificial corneas, tissue engineering in ophthalmology has become more focused on regenerative strategies using biocompatible materials either with or without cells. The stroma makes up the bulk of the corneal thickness and mainly consists of a tightly interwoven network of collagen type I, making it notoriously difficult to recreate in a laboratory setting. Despite the challenges that come with corneal stromal tissue engineering, there has recently been enormous progress in this field. A large number of research groups are working towards developing the ideal biomimetic, cytocompatible and transplantable stromal replacement. Here we provide an overview of the approaches directed towards tissue engineering the corneal stroma, from classical collagen gels, films and sponges to less traditional components such as silk, fish scales, gelatin and polymers. The perfect stromal replacement has yet to be identified and future research should be directed at combined approaches, in order to not only host native stromal cells but also restore functionality. In the field of tissue engineering and regenerative medicine in ophthalmology the focus has shifted towards a common goal: to restore the corneal stroma and thereby provide a new treatment option for patients who are currently blind due to corneal opacification. Currently the waiting lists for corneal transplantation include more than 10 million patients, due to severe donor shortages. Alternatives to the transplantation of a donor cornea include the use of artificial cornea, but these are by no means biomimetic and therefore do not provide good outcomes. In recent years a lot of work has gone into the development of tissue engineered scaffolds and other biomaterials suitable to replace the native stromal tissue. Looking at all the different approaches separately is a daunting task and up until now there was no review article in which every approach is discussed. This review does include all approaches, from classical tissue engineering with collagen to the use of various alternative biomaterials and even fish scales. Therefore, this review can serve as a reference work for those starting in the field and but also to stimulate collaborative efforts in the future.

1 June 2016 in Cornea
Verified
Journal Article
Closed access
IHIrene Ruiz Hidalgo
Irene Ruiz Hidalgo
PRPablo Rodriguez
Pablo Rodriguez
Jos J. RozemaJos J. Rozema
Jos J. Rozema
SDSorcha Ní Dhubhghaill
Sorcha Ní Dhubhghaill
NZNadia Zakaria
Nadia Zakaria
CKCarina Koppen
Carina Koppen
To evaluate the performance of a support vector machine algorithm that automatically and objectively identifies corneal patterns based on a combination of 22 parameters obtained from Pentacam measurements and to compare this method with other known keratoconus (KC) classification methods. Pentacam data from 860 eyes were included in the study and divided into 5 groups: 454 KC, 67 forme fruste (FF), 28 astigmatic, 117 after refractive surgery (PR), and 194 normal eyes (N). Twenty-two parameters were used for classification using a support vector machine algorithm developed in Weka, a machine-learning computer software. The cross-validation accuracy for 3 different classification tasks (KC vs. N, FF vs. N and all 5 groups) was calculated and compared with other known classification methods. The accuracy achieved in the KC versus N discrimination task was 98.9%, with 99.1% sensitivity and 98.5% specificity for KC detection. The accuracy in the FF versus N task was 93.1%, with 79.1% sensitivity and 97.9% specificity for the FF discrimination. Finally, for the 5-groups classification, the accuracy was 88.8%, with a weighted average sensitivity of 89.0% and specificity of 95.2%. Despite using the strictest definition for FF KC, the present study obtained comparable or better results than the single-parameter methods and indices reported in the literature. In some cases, direct comparisons with the literature were not possible because of differences in the compositions and definitions of the study groups, especially the FF KC.

1 March 2018 in Survey of Ophthalmology
Verified
Journal Article
Open access
BBBert Van Den Bogerd
Bert Van Den Bogerd
SDSorcha Ní Dhubhghaill
Sorcha Ní Dhubhghaill
CKCarina Koppen
Carina Koppen
MTMarie-José Tassignon
Marie-José Tassignon
NZNadia Zakaria
Nadia Zakaria
Human corneal endothelium has long been thought to be a nonmitotic cell layer with no endogenous reparative potential. Pathologies that damage endothelial function result in corneal decompensation and, if untreated, blindness. The mainstay of treatment involves partial or complete corneal replacement, amounting to 40% of all corneal transplants performed worldwide. We summarize the case reports describing complications postoperatively in the form of (sub)total graft detachment and those resulting in postoperative bare stroma. Complications during cataract and glaucoma surgeries leading to an uncovered posterior cornea are also included. We discuss the newer treatment strategies that are alternatives for current Descemet membrane endothelial keratoplasty and Descemet stripping automated endothelial keratoplasty, including partial grafts and stripping of the diseased cell layer. In more than half of the cases reviewed, corneal transparency returned despite incomplete or no corneal endothelial cell transplantation. We question the existing paradigm concerning corneal endothelial wound healing in vivo. The data support further clinical study to determine the safety of simple descemethorexis in central endothelial pathologies, such as Fuchs endothelial corneal dystrophy, where presence of healthy peripheral cells may allow successful corneal recompensation without the need for donor cells.

1 January 2014 in Journal of Translational Medicine
Verified
Journal Article
Open access
PDF file
NZNadia Zakaria
Nadia Zakaria
TPTine Possemiers
Tine Possemiers
SDSorcha Ní Dhubhghaill
Sorcha Ní Dhubhghaill
ILInge Leysen
Inge Leysen
Jos J. RozemaJos J. Rozema
Jos J. Rozema
MTMarie-José Tassignon
Marie-José Tassignon
To determine if a standardized, non-xenogenic, reduced manipulation cultivation and surgical transplantation of limbal stem cell grafts is a safe and effective treatment option for patients with total and partial limbal stem cell deficiency.