Viktória Stanová

Dr. Viktória Stanová


Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 December 2023 in Structural Heart
Verified
Journal Article
Open access
VSViktória Stanová
Viktória Stanová
RRRégis Rieu
Régis Rieu
LTLionel Thollon
Lionel Thollon
ESErwan Salaun
Erwan Salaun
JRJosep Rodés-Cabau
Josep Rodés-Cabau
PPPhilippe Pibarot
Philippe Pibarot
It is unknown whether bioprostheses used for transcatheter aortic valve implantation will have similar long-term durability as those used for surgical aortic valve replacement. Repetitive mechanical stress applied to the valve leaflets, particularly during diastole, is the main determinant of structural valve deterioration. Leaflet mechanical stress cannot be measured in vivo. The objective of this in vitro/in silico study was thus to compare the magnitude and regional distribution of leaflet mechanical stress in old vs new generations of self-expanding (SE) vs balloon expandable (BE) transcatheter heart valves (THVs). A double activation simulator was used for in vitro testing of two generations of SE THV (Medtronic CoreValve 26 mm and EVOLUT PRO 26 mm) and two generations of BE THV (Edwards SAPIEN 23 mm vs SAPIEN-3 23 mm). These THVs were implanted within a 21-mm aortic annulus. A noncontact system based on stereophotogammetry and digital image correlation with high spatial and temporal resolution (2000 img/sec) was used to visualize the valve leaflet motion and perform the three-dimensional analysis. A finite element model of the valve was developed, and the leaflet deformation obtained from the digital image correlation analysis was applied to the finite element model to calculate local leaflet mechanical stress during diastole. The maximum von Mises leaflet stress was higher in early vs new THV generation (p < 0.05) and in BE vs SE THV (p < 0.05): early generation BE: 2.48 vs SE: 1.40 MPa; new generation BE: 1.68 vs SE: 1.07 MPa. For both types of THV, the highest values of leaflet stress were primarily observed in the upper leaflet edge near the commissures and to a lesser extent in the mid-portion of the leaflet body, which is the area where structural leaflet deterioration most often occurs in vivo. The results of this in vitro/in silico study suggest that: i) Newer generations of THVs have ∼30% lower leaflet mechanical stress than the early generations; ii) For a given generation, SE THVs have lower leaflet mechanical stress than BE THVs. Further studies are needed to determine if these differences between new vs early THV generations and between SE vs BE THVs will translate into significant differences in long-term valve durability in vivo.

1 June 2018 in EuroIntervention
Verified
Journal Article
Closed access
AZAnne-Sophie Zenses
Anne-Sophie Zenses
MEMorgane Evin
Morgane Evin
VSViktória Stanová
Viktória Stanová
MCMarie-Annick Clavel
Marie-Annick Clavel
PBPaul Barragan
Paul Barragan
RRRégis Rieu
Régis Rieu
The Official Journal of EuroPCR and the European Association of Percutaneous Cardiovascular Interventions (EAPCI)

29 January 2020 in Artificial Organs
Verified
Journal Article
Closed access
PDF file
VSViktória Stanová
Viktória Stanová
AZAnne‐Sophie Zenses
Anne‐Sophie Zenses
LTLionel Thollon
Lionel Thollon
LKLyes Kadem
Lyes Kadem
PBPaul Barragan
Paul Barragan
PPPhilippe Pibarot
Philippe Pibarot

11 October 2021 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
VSViktória Stanová
Viktória Stanová
RRRégis Rieu
Régis Rieu
NCNancy Côté
Nancy Côté
ESErwan Salaun
Erwan Salaun
JRJosep Rodés‐Cabau
Josep Rodés‐Cabau
PPPhilippe Pibarot
Philippe Pibarot

5 July 2021 in Computer Methods in Biomechanics and Biomedical Engineering
Verified
Journal Article
Closed access
VSViktória Stanová
Viktória Stanová
YRYves Godio Raboutet
Yves Godio Raboutet
PBPaul Barragan
Paul Barragan
LTLionel Thollon
Lionel Thollon
PPPhilippe Pibarot
Philippe Pibarot
RRRégis Rieu
Régis Rieu
Calcified aortic stenoses are among the most prevalent form of cardiovascular diseases in the industrialized countries. This progressive disease, with no effective medical therapy, ultimately requires aortic valve replacement - either a surgical or very recently transcatheter aortic valve implantation. Increase leaflet mechanical stress is one of the main determinants of the structural deterioration of bioprosthetic aortic valves. We applied a coupled in vitro/in silico method to compare the timing, magnitude, and regional distribution of leaflet mechanical stress in porcine versus pericardial bioprostheses (Mosaic and Trifecta). A double activation simulator was used for in vitro testing of a bioprosthesis with externally mounted pericardium (Abbott, Trifecta) and a bioprosthesis with internally mounted porcine valve (Medtronic, Mosaic). A non-contact system based on stereophotogammetry and digital image correlation (DIC) with high spatial and temporal resolution (2000 img/s) was used to visualize the valve leaflet motion and perform the three-dimensional analysis. A finite element model of the valve was developed, and the leaflet deformation obtained from the DIC analysis was applied to the finite element model calculate local leaflet mechanical stress throughout the cardiac cycle. The maximum leaflet stress was higher with the pericardial versus the porcine bioprosthesis (2.03 vs. 1.30 MPa) For both bioprostheses the highest values of leaflet stress occurred during diastole and were primarily observed in the upper leaflet edge near the commissures and to a lesser extent in the mid-portion of the leaflet body. In conclusion, the coupled in vitro/in silico method described in this study shows that the highest levels of leaflet stress occur in the regions of the commissures and mid-portion of the leaflet body. This method may have important insight with regard to bioprosthetic valve durability. Our results suggest that, compared to porcine bioprostheses, those with externally mounted pericardium have higher leaflet mechanical stress, which may translate into shorter durability.

7 April 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
KDKatell Delanoë
Katell Delanoë
ESErwan Salaun
Erwan Salaun
RRRégis Rieu
Régis Rieu
CCCote Cote
Cote Cote
PPPhilippe Pibarot
Philippe Pibarot
VSViktória Stanová
Viktória Stanová
Mitral valve regurgitation is among the most prevalent valvular heart diseases and increases with age. Percutaneous therapy has emerged for the management of mitral regurgitation in high surgical risk patients. However, the long-term consequences of these interventions are still not fully understood due to their novelty and the difficulty of developing a strategy specific to the patient’s anatomy and/or pathology. To optimize these outcomes, an in vitro patient-specific approach could provide important insights for the most suitable strategy to use according to the patient profile. To ensure the reliability of this in vitro approach, the aim of this study was to reproduce the physiological behavior of the healthy native mitral valve for future applications. To do so, different silicon combinations reproducing the physiological anatomy of a healthy mitral valve were developed and tested under physiological hemodynamic conditions in a cardiac simulator. The hemodynamic and biomechanical behaviors of each mitral valve model were analyzed and compared to the physiological values provided in the literature. This study identified EcoFlex 00-50 and DragonSkin 10 (Smooth-On Inc., Easton, PA, USA) as the optimal silicon combination resulting in physiological strain values and hemodynamic parameters. These findings could be useful for future patient-specific applications, helping in the optimization of percutaneous mitral valve therapy.