Personalized monitoring of disease biomarkers is of great interest in women’s health. However, existing approaches typically involve invasive inspection or bulky equipment, making them challenging to implement at home. Hence, we present a general strategy for label-free and specific detection of disease biomarkers in physiological media using an aptamer-based biosensor. The biosensor is a graphene field-effect transistor that involves immobilizing the aptamer and a biomolecule-permeable polyethylene glycol (PEG) layer on the graphene surface. The aptamer is capable of specifically binding with the target biomarker, thus inducing a change in the sensing responses. The PEG layer can effectively reduce the nonspecific adsorption of nontarget molecules in the solution, and increase the effective Debye screening length in the region directly adjacent to the graphene. In this work, studies of a biosensor with modification of the aptamer and PEG show that cervical carcinoma biomarkers such as tumor necrosis factor-α and interleukin 6 can be sensitively and specifically detected in undiluted physiological media, with detection limits as low as 0.13 pM for TNF-a and 0.20 pM for IL-6. This work presents a significant method for the general application of the biosensor for disease diagnosis in women’s health.
Early diagnosis of diseases would significantly increase the survival rate of cancer patients. However, current screening methods are complex and costly, making them unsuitable for rapid health diagnosis in daily life. Here, we develop a portable platform based on a planar-gate graphene field-effect transistor functionalized with polydopamine self-assembled film (PDA-GFET), capable of identifying colon cancer through the detection of EpCAM protein, which is expressed on colon cancer-derived exosomes, in clinical samples within 10 min. The PDA self-assembled film on the graphene and gate surface enhances the biosensor’s functionalization area while suppressing non-specific adsorption, thereby achieving detection limits as low as 112 particles/mL. In addition, the PDA-GFET-based detection platform was used to identify EpCAM protein in real clinical samples from healthy individuals and colon cancer patients within 10 min, and the two showed significant differences (p < 0.001). Results indicate that the proposed PDA-GFET-based detection platform is expected to be a potential tool for the early diagnosis of colon cancer.
Saxitoxin (STX) is a highly potent marine biotoxin, and trace contamination in aquatic environments can pose serious risks to human health. Therefore, reliable detection of low-concentration STX is crucial for water safety monitoring. Here, we developed a robust electrochemical aptasensor based on a gold nanoparticle/chitosan (AuNP/CS) conductive network for STX detection in freshwater samples. The chitosan matrix provides a three-dimensional scaffold for aptamer immobilization, while interconnected AuNPs create efficient electron-transfer pathways across the sensing interface. This integrated architecture improves interfacial conductivity and supports stable target-induced aptamer recognition. The aptasensor exhibits a linear response from 1 to 1000 nM and a limit of detection of 0.74 nM, with an apparent dissociation constant Kd = 70.29 ± 29.2 nM, together with high batch-to-batch consistency and long-term stability, retaining 93% of its initial response after 25 days. In spiked freshwater samples, the aptasensor achieved recoveries ranging from 99.10% to 111.33%, demonstrating the practical potential of this platform for monitoring STX contamination in aquatic environments.