15 October 2019 in Metals
Verified
Journal Article
Open access
PDF file
IFIgnacio Fernández-Asián
Ignacio Fernández-Asián
Daniel Torres-LagaresDaniel Torres-Lagares
Daniel Torres-Lagares
Daniel Torres-LagaresDaniel Torres-Lagares
Daniel Torres-Lagares
María-Angeles Serrera-FigalloMaría-Angeles Serrera-Figallo
María-Angeles Serrera-Figallo
ÁGÁlvaro José Martínez González
Álvaro José Martínez González
(1) Background: In today's dentistry, implantology has become a therapeutic resource of choice in certain clinical situations. The design of implants has evolved in several aspects since their inception. Dental implants were initially designed with an external hex connection, although due to force transmission and security in the adjustment of the prosthesis, later implants featured an internal hex connection. This study aims to analyse the mechanical properties of two types of implants (an internal connection and an external connection) from the same manufacturer and their different prosthetic components (union screw between implant and prosthetic abutment, and the abutment itself) when subjected to different types of load. (2) Materials and methods: Intraosseous dental implants of similar shape, design and size, although different in type of connection (external vs. internal), were studied. The specifications of the UNI EN ISO 14801 test standard were used, with all determinations being carried out three times. Finally, the dimensional characterisation of the samples analysed after the dynamic load study was carried out, and the values of both study groups were compared by means of the non-parametric Mann–Whitney U test to find statistically significant differences (p < 0.05). (3) Results: For the static characterisation test, we found between 610.9 N and 986.1 N for the external connection and between 1263.6 N and 1324 N for the internal connection (p = 0.011). All of the dynamic load tests were positive and there was no failure in any of the components studied. (4) Conclusions: After the analysis of the samples studied in vitro, satisfactory results were obtained, demonstrating that both connections can support considerable mechanical loads according to international standards (UNI EN ISO 14801).

13 July 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
MRMaría Rizo-Gorrita
María Rizo-Gorrita
IFIgnacio Fernández-Asián
Ignacio Fernández-Asián
AGAndreina Garcia-De-Frenza
Andreina Garcia-De-Frenza
CVCelia Vazquez-Pachon
Celia Vazquez-Pachon
María-Angeles Serrera-FigalloMaría-Angeles Serrera-Figallo
María-Angeles Serrera-Figallo
JGJose-Luis Gutiérrez-Perez
Jose-Luis Gutiérrez-Perez
The chemical composition and the surface characteristics of dental implants are factors that have a decisive effect on the osseointegration process. The surface characterization at the compositional and topographic level of three dental implants available in the market was performed with different surface treatments: (1) sandblasted and acid etched surface (SLA), (2) hydroxyapatite (HA) and tricalcium phosphate (TCP) blasted surface (HA/TCP), and (3) HA-blasted and non-etching acid washed surface (HA + AW). In addition, an in vitro viability study of MG-63 osteoblast cells was performed with a JC-1 test. To complete the study, an in vivo study was conducted in New Zealand rabbits. The study analyzed the histometric characteristics of the bone formed around the implants at the level of area, volume, bone density, accumulated bone density, and bone–implant contact (BIC). The rabbits were sacrificed at 6 weeks after implants were placed in the tibial metaphysis. No statistically significant differences were observed at the level of cell viability or histometric parameters between the different study groups (p > 0.05). SLA and HA/TCP surfaces were the ones that obtained a higher BIC value. Taking into account the limitations of this study, it can be concluded that the different implant surfaces analyzed favor a good bone response.

23 March 2025 in Bioengineering
Verified
Journal Article
Open access
PDF file
IFIgnacio Fernández-Asián
Ignacio Fernández-Asián
Daniel Torres-LagaresDaniel Torres-Lagares
Daniel Torres-Lagares
María-Angeles Serrera-FigalloMaría-Angeles Serrera-Figallo
María-Angeles Serrera-Figallo
JGJose-Luis Gutiérrez-Perez
Jose-Luis Gutiérrez-Perez
The design of dental implants has undergone minor modifications over the years to reduce possible future complications that may arise from implant rehabilitation. One critical element from a clinical point of view is the implant connection. Given this, the team of authors of the present study decided to biomechanically analyze the effect of implant connection obtained in a possible implant fracture through a systematic review of the published literature. To this end, a search was conducted in the PubMed and Scopus databases. Only finite element studies carried out in vitro and simulation studies were included, discarding clinical studies and related reviews. A total of 19 studies were obtained for analysis and complete study. The conical type is the connection design that demonstrates the best biomechanical behavior. However, there was also significant heterogeneity in the design of the studies, which translates into a substantial source of bias, as well as different types of specific designs within the conical connection. In conclusion, it was established that the design of the connection seems to play a fundamental role in the fatigue resistance of the implant when subjected to load. However, more studies are needed to determine the most optimal specific design.