The effect of stress on irradiation responses of highly oriented pyrolytic graphite (HOPG) was studied by combing molecular dynamics (MD) simulation, proton irradiation, and Raman characterization. MD simulations of carbon knock-on at energies < 60 eV were used to obtain average threshold displacement energies () as a function of strain ranging from 0 to 10%. Simulations at a higher irradiation energy of 2–5 keV were used to study the effect of strain on damage cascade evolution. With increasing tensile strain, was reduced from 35 eV at 0% strain to 31 eV at 10% strain. The strain-reduced led to a higher damage peak and more surviving defects (up to 1 ps). Furthermore, high strains induced local cleavage around the cavities, as one additional mechanism of damage enhancement. Experimentally, HOPG film was folded, and the folded region with the maximum tensile stress was irradiated by a 2 MeV proton beam. Raman characterization showed significantly enhanced D to G modes in comparison to the stress-free irradiation. Based on the strain dependence of and the Kinchin–Pease model, a formula for displacement estimation under different tensile strains is proposed. The stress effects need to be considered in graphite applications in a reactor’s harsh environment where both neutron damage and stress are present.
19 April 2025 in Nuclear Instruments and Methods in Physics Research Section B: Beam Interactions with Materials and Atoms
This study investigates the capabilities of accelerator-based Focused Ion Thermal Analysis (FITA), a remote nondestructive method developed for characterizing thermal properties using a proton beam as a localized heat source. Employing infrared (IR) imaging, FITA captures the evolution of temperature in material samples after the beam is deactivated, enabling precise extraction of thermal properties. However, the performance of FITA is inherently influenced by the IR camera’s resolution and frame rate, which imposes constraints on the types of materials that can be effectively analyzed. Here, a comprehensive series of finite element analysis (FEA) simulations were performed to evaluate the applicability of FITA for a wide range of materials. These simulations assess how variations in IR camera specifications impact the effectiveness of FITA in analyzing different materials. Our findings show that the current method can characterize a wide range of materials, including the majority of nuclear materials typically used in the nuclear industry.
We propose a method to convert the channeling Rutherford backscattering spectrum yield map of a single crystal to a polycrystal through a matrix rotation technique. The rotation matrix is determined by the deviation of the crystal axial direction from the original z axis. The final yield map is created after averaging the rotated yields using the texture function as the weight factor. For highly oriented pyrolytic graphite (HOPG) exhibiting mosaic spread, the method leads to a Gaussian kernel averaging of the map obtained from a single crystal. The yield map of a single crystal is obtained by a simulation of ion trajectories in a potential field described by Moliere screened Coulomb potentials. Yield maps are calculated under variousσ values (standard deviations of mosaic spread). The simulated results are compared with experimental results obtained using 1.2 MeV alpha particle. σ is extracted through the best fitting, demonstrating that the method can be used to obtain texture details. The effects of mosaic spread on minimum yield χmin and the half-width at half maximum of angular scans ψ1/2 are systematically modeled and compared with previous theoretical equations. The study also shows that previous theoretical equations are valid only at small σ values. The proposed method can be applied to any type of polycrystal and is not limited to HOPG. It provides near-surface mosaic spread and crystallography information with a longitudinal depth resolution of tens of nanometers and is not influenced by grain shapes.
The SRIM (Stopping and Range of Ions in Matter) computer code is widely used to predict depth-dependent damage and implanted-ion profiles generated by charged particles. Although SRIM has served as the de facto standard for decades, recent studies have revealed discrepancies between predicted and measured ion ranges, implying that the electronic stopping power tables incorporated in SRIM require revision. The largest and most persistent deviations appear to occur for Ni+ ions in iron-base and nickel-base alloys, and also for pure iron, nickel and molybdenum. The overestimate appears to have been an error introduced for Ni+ ions when moving from TRIM to SRIM since the former code yields better agreement. A technique was devised to separate the five naturally occurring nickel isotopes to implant a low natural abundance isotope into pure nickel to provide a strong signal-to-noise ratio in defining the implanted distribution. Experimental range data were derived for 62Ni ions implanted into both high-purity nickel and high-purity iron at 2.0, 3.5, and 5.0 MeV, using secondary ion mass spectrometry (SIMS) to measure the depth distributions of deposited ions. The SRIM-predicted ranges systematically overpredict the experimentally obtained ranges, with the most significant overpredictions observed for nickel self-ion irradiation. To interpret these results, first-principles electronic-stopping data from real-time, time-dependent, density-functional theory were coupled with molecular-dynamics ion-transport simulations, revealing that explicit treatment of projectile core-electron excitations markedly improves agreement with experiment. Together, the experimental and modeling results establish new quantitative benchmarks for refining stopping-power formulations and enhancing the predictive accuracy of ion-range simulations.
Irradiation responses of reactor structural alloys exhibit a strong temperature dependence, making comprehensive testing matrices costly and time-consuming. Here, we present a high-throughput testing method based on arrays of additively manufactured pillars of different heights subjected to a single irradiation. All pillars share the same heated substrate, while differences in height produce distinct thermal profiles, resulting in different irradiation temperatures at the pillar tops. Consequently, temperature-dependent radiation responses can be evaluated simultaneously within a single experiment. As a demonstration, temperature-dependent void swelling in additively manufactured 316L stainless steel was mapped using a single 5 MeV Fe self-ion irradiation. Transmission electron microscopy revealed a maximum swelling temperature of approximately 575 °C. By analyzing swelling as a function of local dpa within the safe analysis zone, where both surface effects and injected-interstitial effects were excluded, the swelling behavior was found to consist of a temperature-dependent incubation period followed by a nearly temperature-independent growth stage. A two-dimensional swelling map as a function of temperature and local dpa was constructed from the experimental data. Dislocation densities generally decreased with increasing irradiation temperature, consistent with enhanced thermal recovery of the irradiation-induced network. These results demonstrate the feasibility of variable-height pillar arrays as a high-throughput platform for studying temperature-dependent radiation responses.