A simple strategy to rapidly detect glucose was developed by utilizing core (Fe 3 O 4 )–shell (Pt) magnetic nanoparticles (Fe 3 O 4 @Pt NPs) as a nanoenzyme and a paper-based colorimetric sensor. In the presence of H 2 O 2 , Fe 3 O 4 @Pt NPs catalyze the redox reaction of 3,3′,5,5′-tetramethylbenzidine (TMB) and generate a colour change from colourless to blue. On this basis, a colorimetric glucose sensing method assisted by glucose oxidase (GOx) was developed. Under the optimal conditions, the detection limits of the proposed assay for H 2 O 2 and glucose were 0.36 µM and 1.27 µM, respectively. Furthermore, the fabricated colorimetric method was successfully applied to analyze glucose concentrations by using a paper device as a measuring platform without a spectrometer. In addition, this method exhibited satisfactory recovery for glucose detection in human serum samples and urine samples, which satisfied the requirements for normal detection of real samples. This study provides a good candidate for health monitoring of glucose and also expands the applications of nanoenzymes and paper-based colorimetric assays in point-of-care testing.
The exploitation of a bifunctional material for both identifying and extracting heavy metal ions (HMIs) is essential but still poses a major hurdle. In this work, a novel magnetic fluorescent nanocomposite (Fe3O4/CD@SiO2-QD) was successfully prepared for the specific detection and removal of Cu2+. Magnetic fluorescent nanoparticles (Fe3O4/CDs) exhibiting blue fluorescence were synthesized via a one-step hydrothermal approach, and a magnetic ratiometric fluorescence sensor was prepared after SiO2 and red fluorescent CdTe quantum dots were coated on the surface. When Cu2+ is present in the solution, the red fluorescence of the magnetic ratiometric fluorescence sensor is quenched, and the blue fluorescence remains essentially unchanged, resulting in a ratiometric fluorescence effect, which can be used for the sensitive determination of Cu2+; the magnetism can be used concurrently for the removal of Cu2+ to achieve detection and removal, and the detection results exhibit good linearity within the 2.5–100 μM range, with a limit of detection of 0.23 μM. This method was used for the spiked determination of copper ions in actual samples, with recoveries ranging from 93.02 to 107.31%. In addition, the sensor effectively removes Cu2+, and each gram of magnetic ratiometric fluorescence sensor can remove up to 72 mg of copper ions. Therefore, our prepared magnetic fluorescence sensor can introduce an innovative strategy for the determination and removal of copper ions in environmental or biological samples.
The precise identification and detection of circulating tumor cells (CTCs) is significant for the early diagnosis and prognostic treatment of cancer. However, it remains a challenge to detect CTCs with high sensitivity and specificity. In this study, a colorimetric sensor for the analysis of CTCs was constructed based on dual-aptamer recognition and core (Fe3O4)–shell (Pt) nanoparticle (Fe3O4@Pt NP) nanozymes coupled with a G-quadruplex as a signal transducer/amplifier. The results show that the linear range of the designed colorimetric sensor is 50–4000 cells and the detection limit is 4 cells. The constructed aptasensor could be extended to identify various CTCs by changing the aptamers, and holds great potential in precise tumor diagnosis.
Heavy metal contamination in foodstuff poses a serious threat to food safety and human health; therefore, the development of toxic heavy metal detection methods is crucial. However, lots of these methods, based on traditional nanomaterials, have unavoidable limitations, such as high instrument cost, complicated operation procedures, or a long analysis time, which restrict their wide application in heavy metal detection. This review aims to conduct a systematic overview of major analytical methods using novel upconversion nanoparticles (UCNPs) for assessing heavy metal ions in complex food matrices in the context of food safety and show their potential application prospects when combined with big data and artificial intelligence. Due to their unique optical properties, good bio-compatibility, and tunable interfacial chemistry, UCNPs have shown significant detection advantages in the field of food heavy metal analysis. The review summarizes the progress of the application of UCNPs in heavy metal detection in food. Despite the development of new technologies such as artificial intelligence, and the continuous optimization and improvement of its own design, the wide application of UCNPs in food safety detection still has great potential for further development.