Mandibular growth and morphology are important topics in the field of oral and maxillofacial surgery. For diagnostic and planning purposes, a normative database or statistical shape model of the growing mandible can be of great benefit. A collection of 874 cadaveric children’s mandibles with dental age between 1 and 12 years old were digitized using computed tomography scanning and reconstructed to three-dimensional models. Point correspondence was achieved using iterative closest point and coherent point drift algorithms. Principal component analysis (PCA) was applied to find the main modes of variation in the data set. The average mandible was presented, along with the first ten PCA modes. The first mode explained 78% of the total variance; combining the first ten modes accumulated to 95% of the total variance. The first mode was strongly correlated with age and hence, with natural growth. This is the largest study on three-dimensional mandibular shape and development conducted thus far. The main limitation is that the samples lack information such as gender and cause of death. Clinical application of the model first requires validation with contemporary samples.
Purpose The purposes of the study are to outline the complexity of diagnosing internal herniation after Roux-en-Y gastric bypass (RYGB) surgery and to investigate the added value of computed tomography angiography (CTA) for diagnosing internal herniation. Materials and Methods A cadaver study was performed to investigate the manifestations of internal hernias and mesenteric vascularization. Furthermore, a prospective, ethics approved study with retrospective interpretation was conducted. Ten patients, clinically suspected for internal herniation, were prospectively included. After informed consent was obtained, these subjects underwent abdominal CT examination, including additional arterial phase CTA. All subjects underwent diagnostic laparoscopy for suspected internal herniation. The CTA was used to create a 3D reconstruction of the mesenteric arteries and surgical staples (3D CTA). The 3D CTA was interpreted, taking into account the presence and type of internal hernia that was found upon laparoscopy. Results Cadaveric analysis demonstrated the complexity of internal herniation. It also confirmed the expected changes in vascular structure and surgical staple arrangement in the presence of internal herniation. 3D CTA studies of the subjects with active internal hernias demonstrated remarkable differences when compared to control 3D CTA studies. The blood supply of herniated intestinal limbs in particular showed abnormal trajectories. Additionally, enteroenterostomy staple lines had migrated or altered orientation. Conclusion 3D CTA is a promising technique for diagnosing active internal hernias. Our findings suggest that for diagnosing internal hernias, focus should probably shift from routine abdominal CT examination towards the 3D assessment of the mesenteric vasculature and surgical staples.
1 May 2021 in British Journal of Oral and Maxillofacial Surgery
Sagittal split ramus osteotomy (SSRO) with large mandibular advancements is a common surgical procedure and could be indicated for patients with sleep apnoea. As a large variety of fixation methods is used for the stabilisation of SSRO, a biomechanical test model was used to analyse which fixation technique was most stable. For this in vitro study, 80 polyurethane hemimandibles with a prefabricated SSRO were used as substrates. Loads in Newtons were recorded at displacements of the mandibular incisive edge at 1mm, 3mm and 5mm. The samples were divided into two groups: mandibular advancements of 10mm and 15mm. In both groups, four fixation techniques were used: (A) one four-hole miniplate; (B) two four-hole miniplates; (C) one four-hole miniplate plus one bicortical screw; and (D) three bicortical screws in an inverted-L arrangement. In group 1, three bicortical screws resulted in the best stability, and in group 2, two miniplates resulted in the best stability. The use of two miniplates did not show significant differences between both groups. Other fixation methods showed more stability with 10mm advancements. This study therefore suggests that in SSRO with advancements exceeding 10mm, the use of two miniplates is the optimal means of providing rigid fixation.
16 April 2024 in Computers in Biology and Medicine
The available reference data for the mandible and mandibular growth consists primarily of two-dimensional linear or angular measurements. The aim of this study was to create the first open-source, three-dimensional statistical shape model of the mandible that spans the complete growth period. Computed tomography scans of 678 mandibles from children and young adults between 0 and 22 years old were included in the model. The mandibles were segmented using a semi-automatic or automatic (artificial intelligence-based) segmentation method. Point correspondence among the samples was achieved by rigid registration, followed by non-rigid registration of a symmetrical template onto each sample. The registration process was validated with adequate results. Principal component analysis was used to gain insight in the variation within the dataset and to investigate age-related changes and sexual dimorphism. The presented growth model is accessible globally and free-of-charge for scientists, physicians and forensic investigators for any kind of purpose deemed suitable. The versatility of the model opens up new possibilities in the fields of oral and maxillofacial surgery, forensic sciences or biological anthropology. In clinical settings, the model may aid diagnostic decision-making, treatment planning and treatment evaluation.
1 September 2021 in British Journal of Oral and Maxillofacial Surgery
Adequate positioning of an orbital implant during orbital reconstruction surgery is essential for restoration of the pre-traumatised anatomy, but visual appraisal of its position is limited by the keyhole access and protruding soft tissues. A positioning instrument that attaches to the implant was designed to provide feedback outside the orbit. The goal of this study was to evaluate the accuracy of placement with the instrument and compare it with the accuracy of placement by visual appraisal. Ten orbits in five human cadaver heads were reconstructed twice: once using visual appraisal and once using the instrument workflow. No significant improvement was found for the roll (5.8° vs 3.4°, respectively, p=0.16), pitch (2.1° vs 1.5°, p=0.56), or translation (2.9 mm vs 3.3 mm, p=0.77), but the yaw was significantly reduced if the instrument workflow was used (15.3° vs 2.9°, p=0.02). The workflow is associated with low costs and low logistical demands, and may prevent outliers in implant positioning in a clinical setting when intraoperative navigation or patient-specific implants are not available.
8 April 2025 in International Journal of Oral and Maxillofacial Surgery
The primary aim of this study was to assess the accuracy and predictability of a splintless treatment protocol for edentulous patients with moderate to severe obstructive sleep apnoea (OSA) undergoing maxillomandibular advancement (MMA). Ten consecutive edentulous patients treated with MMA were enrolled in this retrospective study. All cases were virtually planned, followed by computer-aided design of individual osteotomy cutting guides and patient-specific implants. For the maxilla, the mean discrepancy between the planned and achieved right to left, posterior to anterior, and cranial to caudal translations was 0.3 ± 0.2 mm, 1.0 ± 0.6 mm, and 0.8 ± 0.6 mm, respectively. There was a mean discrepancy of 0.5° ± 0.5°, 2.5° ± 2.0°, and 0.3° ± 0.4° for roll, pitch, and yaw of the maxilla, respectively. The mean discrepancy of the mandible osteotomy gap was 1.2 ± 1.0 mm on the right side and 0.8 ± 0.5 mm on the left. Surgical success was achieved in nine patients, one of whom met the criteria for surgical cure. On average, the apnoea-hypopnea index was reduced by 72%. The results of this study indicate that the splintless treatment protocol for MMA applied in edentulous OSA patients is highly accurate, predictable, and effective in the treatment of OSA.