Drew Hall

Dr. Drew Hall

orcid

Research Focus & Metrics

Academic Career Length

19Years (2008-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 October 2009 in Nature Medicine
Verified
Journal Article
Closed access
PDF file
RGRichard S Gaster
Richard S Gaster
DHDrew Hall
Drew Hall
CNCarsten H Nielsen
Carsten H Nielsen
SOSebastian J Osterfeld
Sebastian J Osterfeld
HYHeng Yu
Heng Yu
SWShan Wang
Shan Wang

30 December 2008 in Proceedings of the National Academy of Sciences
Verified
Journal Article
Closed access
PDF file
SOSebastian J. Osterfeld
Sebastian J. Osterfeld
HYHeng Yu
Heng Yu
RGRichard S. Gaster
Richard S. Gaster
SCStefano Caramuta
Stefano Caramuta
LXLiang Xu
Liang Xu
SWShan Wang
Shan Wang
Magnetic nanotags (MNTs) are a promising alternative to fluorescent labels in biomolecular detection assays, because minute quantities of MNTs can be detected with inexpensive giant magnetoresistive (GMR) sensors, such as spin valve (SV) sensors. However, translating this promise into easy to use and multilplexed protein assays, which are highly sought after in molecular diagnostics such as cancer diagnosis and treatment monitoring, has been challenging. Here, we demonstrate multiplex protein detection of potential cancer markers at subpicomolar concentration levels and with a dynamic range of more than four decades. With the addition of nanotag amplification, the analytic sensitivity extends into the low fM concentration range. The multianalyte ability, sensitivity, scalability, and ease of use of the MNT-based protein assay technology make it a strong contender for versatile and portable molecular diagnostics in both research and clinical settings.

10 April 2011 in Nature Nanotechnology
Verified
Journal Article
Open access
PDF file
RGRichard S. Gaster
Richard S. Gaster
LXLiang Xu
Liang Xu
SHShu-Jen Han
Shu-Jen Han
RWRobert J. Wilson
Robert J. Wilson
DHDrew Hall
Drew Hall
SWShan Wang
Shan Wang
Monitoring the kinetics of protein interactions on a high-density sensor array is vital to drug development and proteomic analysis. Label-free kinetic assays based on surface plasmon resonance are the current gold standard, but they have poor detection limits, suffer from non-specific binding, and are not amenable to high-throughput analyses. Here, we show that magnetically responsive nanosensors that have been scaled to over 100,000 sensors per cm2 can be used to measure the binding kinetics of various proteins with high spatial and temporal resolution. We present an analytical model that describes the binding of magnetically labelled antibodies to proteins that are immobilized on the sensor surface. This model is able to quantify the kinetics of antibody–antigen binding at sensitivities as low as 20 zeptomoles of solute.

14 April 2019 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
ABAbbas Barfidokht
Abbas Barfidokht
RMRupesh K. Mishra
Rupesh K. Mishra
RSRajesh Seenivasan
Rajesh Seenivasan
SLShuyang Liu
Shuyang Liu
LHLee J. Hubble
Lee J. Hubble
DHDrew Hall
Drew Hall

1 May 2010 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
DHDrew Hall
Drew Hall
RGR.S. Gaster
R.S. Gaster
TLT. Lin
T. Lin
SOS.J. Osterfeld
S.J. Osterfeld
SHS. Han
S. Han
SWShan Wang
Shan Wang

29 January 2023 in Biosensors and Bioelectronics
Verified
Journal Article
Open access
NSNaveen K. Singh
Naveen K. Singh
SCSaeromi Chung
Saeromi Chung
ACAn-Yi Chang
An-Yi Chang
Joseph WangJoseph Wang
Joseph Wang
DHDrew Hall
Drew Hall
Stress is part of everyone's life and is exacerbated by traumatic events such as pandemics, disasters, violence, lifestyle changes, and health disorders. Chronic stress has many detrimental health effects and can even be life-threatening. Long-term stress monitoring outside of a hospital is often accomplished by measuring heart rate variability. While easy to measure, this digital biomarker has low specificity, greatly limiting its utility. To address this shortcoming, we report a non-invasive, wearable biomolecular sensor to monitor cortisol levels in sweat. Cortisol is a neuroendocrine hormone that regulates homeostasis as part of the stress pathway. Cortisol is detected using an electrochemical sensor functionalized with a pseudoknot-assisted aptamer and a flexible microfluidic sweat sampling system. The skin-worn microfluidic sampler provides rapid sweat collection while separating old and new sweat. The conformation-switching aptamer provides high specificity towards cortisol while being regenerable, allowing it to monitor temporal changes continuously. The aptamer was engineered to add a pseudoknot, restricting it to only two states, thus minimizing the background signal and enabling high sensitivity. An electrochemical pH sensor allows pH-corrected amperometric measurements. Device operation was demonstrated invitro with a broad linear dynamic range (1 pM - 1 μM) covering the physiological range and a sub-picomolar (0.2 pM) limit of detection in sweat. Real-time, on-body measurements were collected from human subjects using an induced stress protocol, demonstrating in-situ signal regeneration and the ability to detect dynamic cortisol fluctuations continuously for up to 90 min. The reported device has the potential to improve prognosis and enable personalized treatments.