Dipu Sarkar

Dr. Dipu Sarkar


Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2021 in Electric Power Systems Research
Verified
Journal Article
Closed access
SGSravan Kumar Gunturi
Sravan Kumar Gunturi
DSDipu Sarkar
Dipu Sarkar

10 October 2020 in Journal of Ambient Intelligence and Humanized Computing
Verified
Journal Article
Closed access
PDF file
DSDipu Sarkar
Dipu Sarkar
SGSravan Kumar Gunturi
Sravan Kumar Gunturi

6 May 2021 in International Journal of System Assurance Engineering and Management
Verified
Journal Article
Closed access
PDF file
DSDipu Sarkar
Dipu Sarkar
SKSagar Kudkelwar
Sagar Kudkelwar


15 February 2019 in Journal of King Saud University – Engineering Sciences
Verified
Journal Article
Open access
PDF file
DSDipu Sarkar
Dipu Sarkar
PKPushpanjalee Konwar
Pushpanjalee Konwar
ADAbhinandan De
Abhinandan De
SGSanjay Goswami
Sanjay Goswami
The topological changes and re-configuration can be brought into an existing power network by operation of sectionalizing switches on the feeder lines. Distribution networks can be operated either in meshed or in radial configuration. While primary meshed distribution networks have advantages like lower short circuit current, reduced overall conductor length and increased reliability and fault tolerance, the radial networks on the other hand stand-out on their merits of simple installation and easier relay coordination. An optimal radial network can operate at higher efficiency owing to its reduced power losses and can offer higher voltage stability. Transformation of a primary meshed network to a radially reconfigured optimal network requires selection of the “best” set of switches on the feeders that are to be opened or closed so that each feeder can be operated close to its maximum loadability limit and the resulting optimal network operates at its lowest feasible value of power loss and highest voltage stability index. This theoretical concept of optimal power network radialization is however difficult to implement in practice due to the heavy computational burden and unacceptably long searching time as the number of feasible alternative configurations is usually massive for large power networks. Given the extent of the search space, the heuristic search approaches are usually more practical and common in power network reconfiguration. This paper presents a novel guided search approach based on Edmond’s Maximal Spanning Tree Algorithm to achieve the optimal radial configuration for an arbitrary power network rapidly and efficiently. Efficacy of the proposed method has been tested on 30-node and 57-node mesh distribution networks with encouraging results.

2 October 2019 in Smart Science
Verified
Journal Article
Closed access
DSDipu Sarkar
Dipu Sarkar
SKSagar Kudkelwar
Sagar Kudkelwar
DSDebasree Saha
Debasree Saha
This paper proposed a novel optimization technique derived from the crow search algorithm (CSA) for overcurrent (OC) relay coordination in mesh distribution networks. CSA is a meta-heuristic optimizer algorithm, influenced by the cleverness approach of crows. This algorithm can be treated easily by changing only two parameters like, flock size and iteration. In the present work an objective function (OF) is build up to work out the problems of relay coordination developed from time dial (TDS) setting and also the competence of the proposed technique is verified for four different power system networks and compared with existing techniques. Result and performances are the evidence that the suggested scheme is efficient, precise and simple. Abbreviation: BBO: Biogeography-Based Optimization; BSA: Backtracking Search Algorithm; β and α: standard constant for IDMT relay; CFA: Chaotic Firefly Algorithm; CGA: Continuous Genetic Algorithm; CP: Consciousness Possibility; CSA: Crow Search Algorithm; CT: current transformer; CTI: coordination time interval; D: element of search space; DE: Differential Evolution; EA: Evolutionary Algorithm; EI: extremely Inverse; FL: flight length; GA: Genetic Algorithm; GWO: Grey Wolf Optimization; HBA: Honey Bee Algorithm; HAS: Harmony Search Algorithm; IDMT: Inverse Definite Minimum Time; IWO: Invasive Weed Optimization; itermax: maximum iterations; Ifault: fault current; Ip: pickup current; LP: Linear Program; MILP: Mixed integer linear program; mj: location of crow j; MVPA: Most Valuable Player Algorithm; N: flock size; NLP: Non-linear Program; OC: Overcurrent; OF: objective function; PSO: Particle Swarm Optimization; PSM: plug setting multiplier; RTA: Root Tree Algorithm; SI: simple inverse; s: seconds; SM: simplex method; TDS: Time Dial Setting; TLBO: Teaching Learning BasedOptimization; Tpk: operating time of primary relay at fault k; Tbk: operating time of back up relay at fault k. top: operating time of relay; WCA: water Cycle Algorithm; Tik: operating time of ith relay at fault k; VI: very inverse; Wj: weight factor; z: objective function