Yang Liu

Dr. Yang Liu


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 February 2025 in Buildings
Verified
Journal Article
Open access
PDF file
XLXingwang Liu
Xingwang Liu
QMQingkai Meng
Qingkai Meng
LXLiwen Xu
Liwen Xu
YLYang Liu
Yang Liu
XTXinpeng Tian
Xinpeng Tian
This paper introduces a new self-locking-unlockable modular building with an inter-module connection, and its seismic performance is investigated. The new connection can realize fast connection and unlocking during construction through exceptional design. In this paper, taking the Tianjin Binhai Apartment project as the background, for the actual force situation of the new connection, considering the influence of corrugated steel plate stiffness, a simplified model of the connection is constructed by using multi-fold elastic connection, and the corrugated steel plate stiffness is simulated with equivalent support. In the MIDAS Gen 2021 software, the five-story and six-story structural models using traditional rigid connections and new connections were established, respectively, and reaction spectrum analysis was carried out. Meanwhile, seismic waves that comply with codes were selected for dynamic time course analysis. The results show that the stress ratios of all components of the new connection model and the traditional rigid model are less than 1. Among them, the maximum stress ratios of both floor beams are 0.745 and 0.725, respectively; the maximum stress ratios of the modular columns are 0.655 and 0.494, respectively; the stress ratios of the ceiling beams are all less than 0.5; and the two models show good strength and stiffness reserves, following the design principle of strong columns and weak beams and verifying the reliability of the new connection model. Meanwhile, it is found that the inter-story displacement angle of the six-story structure with the new connections is less than the normative value under the action of rare earthquakes, and the difference in top displacement is about 18% compared with that of the rigid structure, so it is suggested that the new connections can be applied within the height of six stories.

15 March 2025 in Buildings
Verified
Journal Article
Open access
PDF file
XLXingwang Liu
Xingwang Liu
WSWenya Sun
Wenya Sun
HLHongtao Li
Hongtao Li
YLYang Liu
Yang Liu
LXLiwen Xu
Liwen Xu
FLFan Liu
Fan Liu
The pier-type repair equipment for bridges is a crucial branch of bridge emergency repair. However, the existing bridge pier repair equipment predominantly utilizes rod systems, which require substantial assembly work, hindering the rapid restoration of damaged bridges. Modular steel structure buildings, as a highly integrated form of prefabricated construction, can play a significant role in emergency rescue operations. Based on the modular architectural design concept, this paper proposes a new type of modular steel structure emergency repair pier joint that facilitates rapid assembly and connection between modular units. Using ABAQUS 2022 software to establish a finite element model of the joint, the bending performance under lateral displacement loads perpendicular to the joint opening direction (X-direction in the model coordinate system) and parallel to the joint opening direction (Z-direction in the model coordinate system) is analyzed. The influence of the width-to-thickness ratio of the upper corner piece base plate D/t1 (where D is the width of the upper corner piece base plate and t1 is the thickness of the upper corner plate), the height-to-thickness ratio of the lower corner piece top plate h/t2 (where h is the height of the protrusion of the lower corner piece and t2 is the thickness of the lower corner piece top plate), the height of the protrusion of the lower corner piece (h), and the bolt diameter (d) on the bending performance of the joint is investigated. Recommendations for the design values of the joint are provided. Then, the flexural behavior of the joint under 0.1, 0.2, and 0.3 axial compression ratios is studied, respectively. The results show that with the increase of axial compression ratio, the yield rotation angle and ultimate rotation angle of the joint decrease, and the bearing capacity decreases faster after the joint reaches the ultimate bearing capacity. When the joint is subjected to the X-direction horizontal lateral displacement load, the initial flexural stiffness and flexural capacity of the joint increase with an increase in the axial compression ratio. When subjected to the horizontal lateral displacement load in the Z-direction, the initial bending stiffness of the joint increases with an increase in the axial compression ratio, and the bending capacity does not change much. In addition, the joint is classified; from the perspective of load-bearing capacity, it is a partially resistant joint, and from the perspective of stiffness, it is a semi-rigid joint. Finally, a simplified calculation model for the joint is proposed based on the component method.

9 May 2026 in Buildings
Verified
Journal Article
Open access
PDF file
XLXingwang Liu
Xingwang Liu
FLFan Liu
Fan Liu
HLHongwei Li
Hongwei Li
CLChenxu Li
Chenxu Li
YLYang Liu
Yang Liu
XHXiang Hou
Xiang Hou
Inter-module connections are the critical load-transfer components in modular steel buildings (MSBs), whose mechanical behavior directly governs the overall safety and seismic performance of the entire structural system. To address the unresolved issue that the influence of complex loading conditions, especially the coupling effect of biaxial bending, on the load-transfer mechanism and degradation law of bayonet-type self-locking and unlockable connections remains poorly understood, two groups of full-scale quasi-static tests were conducted in this study. Specimen S1 (0°) was designed for the in-plane compression–bending–shear loading condition, while Specimen S2 (45°) was designed for the spatial compression–biaxial bending–shear loading condition. The test results demonstrate that both groups of specimens exhibit typical three-stage mechanical characteristics. The average initial stiffness of Specimen S1 (0°) is 5.47 kN/mm, while that of Specimen S2 (45°) is 6.08 kN/mm. The average ultimate load of S1 (0°) reaches 162.8 kN, and that of S2 (45°) is 164.85 kN. The average ductility coefficient of S1 (0°) and S2 (45°) is 2.79 and 2.14, respectively. Comparative analysis indicates that Specimen S1 (0°) presents superior energy dissipation capacity and ductility, while Specimen S2 (45°) has higher initial stiffness accompanied by faster stiffness degradation in the late loading stage. A high-fidelity refined FE model of the bayonet-type self-locking and unlockable connection was established. The FE analysis results are in good agreement with the test results, with the relative error of the positive flexural bearing capacity controlled within 5%. On this basis, parametric FE analysis was carried out to explore the influence of axial compression ratio on the mechanical performance of the connection. Furthermore, theoretical calculation formulas for the ultimate flexural bearing capacity of the connection under in-plane compression–bending–shear loading and spatial compression–biaxial bending–shear loading were proposed respectively. The calculated results are compared with the test data, with all relative errors within 5%, which verifies that the proposed formulas have favorable prediction accuracy for the ultimate flexural bearing capacity of the connection under both aforementioned complex loading conditions.

17 June 2025
Verified
Book Chapter
Closed access
PDF file
GLGuannan Lu
Guannan Lu
ZCZhihua Chen
Zhihua Chen
YLYang Liu
Yang Liu
XZXu Zhong
Xu Zhong
NGNing Guo
Ning Guo
BZBingzhen Zhao
Bingzhen Zhao

22 September 2023 in Journal of Building Engineering
Verified
Journal Article
Closed access
JLJiadi Liu
Jiadi Liu
SYShichun Yan
Shichun Yan
ZCZhihua Chen
Zhihua Chen
YLYang Liu
Yang Liu
HFHao Feng
Hao Feng
JDJipeng Du
Jipeng Du