Akbar Abdi Saray

Dr. Akbar Abdi Saray


Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
27 July 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MDMahdieh Mokhtari Dorostkar
Mahdieh Mokhtari Dorostkar
ASAkbar Abdi Saray
Akbar Abdi Saray
Polymethyl methacrylate (PMMA) stands out for its widespread use in medical and industrial applications due to its transparency, impact resistance, lightweight nature, and weather durability, and ease of fabrication. In this study, we investigate a novel composite material combining PMMA with tungsten oxide (WO3), a high-atomic-number filler known to enhance gamma radiation shielding. Composite samples with varying weight fractions of WO3 were simulated using Monte Carlo particle transport codes, MCNP6 and GEANT4. Key shielding parameters, including the effective atomic number (via Phy-X), attenuation coefficients (via XCOM), linear and mass attenuation coefficients, mean free path, half-value layer, and tenth-value layer (via MCNP6, GEANT4, and experimental data) were analyzed. Experimental validation was performed using 137Cs gamma source. Remarkably, the addition of only 0.5% tungsten oxide resulted in more than a 60% increase in the linear attenuation coefficient, an 80% reduction in the mean free path, and over an 80% decrease in the half-value layer, compared to pure PMMA. Importantly, the composite retained high optical transparency at low filler concentrations, making it an ideal candidate for transparent radiation shielding applications such as protective windows, protective screens, medical barriers, industrial monitoring panels, and protective eyewear. These findings highlight the strong potential of PMMA-WO3 composites as effective, lightweight, and transparent gamma radiation shields.

23 October 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
FIFarzad. Isazadeh
Farzad. Isazadeh
ASAkbar Abdi Saray
Akbar Abdi Saray
In this study, the shielding features of six samples of the polyester (PE)/WO3 polymer composite against gamma rays (137Cs, 22Na, 60Co, and 133Ba sources) were evaluated via an experimental setup in the laboratory, using GEANT4 and MCNP Monte Carlo codes, as well as Phy-X/PSD and XCOM online programs. To study the structure of the composites, the X-ray diffraction (XRD) and scanning electron microscopy (SEM) analyses were conducted. Moreover, parameters such as the linear attenuation coefficient (LAC), mass attenuation coefficient (MAC), half-value layer (HVL), tenth-value layer (TVL), mean free path (MFP), effective atomic number (Zeff), and effective electron density (Neff) were calculated and compared for the six samples. The values of the MAC parameter for the six samples (W0, W1, W2, W3, W4, and W5) and for the experimental measurements are 0.0712 ± 0.003, 0.0714 ± 0.001, 0.0764 ± 0.002, 0.0791 ± 0.004, 0.0796 ± 0.006, and 0.0823 ± 0.003 cm2/g (662 keV), 0.0887 ± 0.002, 0.0889 ± 0.005, 0.0893 ± 0.007, 0.0902 ± 0.003, 0.0913 ± 0.008, and 0.0938 ± 0.002 cm2/g (511 keV),0.0577 ± 0.004, 0.0576 ± 0.006, 0.0568 ± 0.009, 0.0561 ± 0.002, 0.0560 ± 0.005, and 0.0551 ± 0.002 cm2/g (1.275 MeV),0.0615 ± 0.006, 0.0614 ± 0.008, 0.0605 ± 0.008, 0.0601 ± 0.002, 0.0596 ± 0.001, and 0.0593 ± 0.008 cm2/g (1.173 MeV),0.0581 ± 0.002, 0.0579 ± 0.003, 0.0572 ± 0.003, 0.0568 ± 0.003, 0.0565 ± 0.005, and 0.0560 ± 0.001 cm2/g (1.332 MeV), and 0.1012 ± 0.002, 0.1015 ± 0.001, 0.1035 ± 0.001, 0.1066 ± 0.005, 0.1099 ± 0.008, and 0.1201 ± 0.007 cm2/g (356 keV), respectively. According to the results, the W5 samples can be selected as the most effective shielding material among the samples. In addition, the experimental data and the simulated values obtained from the four mentioned programs were in good agreement, indicating that the Monte Carlo codes and online programs are reliable tools for studying nuclear reactions with high accuracy while also saving time and costs.


2 August 2025 in Scientific Reports
Verified
Journal Article
Open access
PDF file
MDMahdieh Mokhtari Dorostkar
Mahdieh Mokhtari Dorostkar
ASAkbar Abdi Saray
Akbar Abdi Saray
Polymer-based composites are increasingly explored for gamma radiation shielding due to their lightweight nature, ease of fabrication, and versatility. Among these composites, poly(methyl methacrylate) (PMMA), also known as Lucite, is widely used in medical and industrial applications. In this study, a novel PMMA-based composite reinforced with varying weight fractions (2.5–10 wt%) of mercury oxide (HgO) was developed and evaluated for its gamma shielding performance using both experimental methods and Monte Carlo simulations with a 137Cs source (662 keV). Two simulation platforms, MCNP6 and GEANT4, were used to compute key shielding parameters of linear attenuation coefficient (LAC), mass attenuation coefficient (MAC), half-value layer (HVL), tenth-value layer (TVL), mean free path (MFP), and effective atomic number (Zeff). Simulated results agreed closely with the experimental data, with discrepancies under 5%, which validated the reliability of the models. Experimentally, the LAC increased from 0.044 cm−1 for pure PMMA to 0.096 cm−1 at 10 wt% HgO, more than doubling the attenuation capability. The HVL correspondingly decreased from 15.47 cm to 7.19 cm, and the Zeff increased modestly from 3.6 to 4.1. These improvements demonstrated the composite’s enhanced shielding effectiveness with increasing HgO content. The material also maintained good transparency at lower loadings, supporting its potential for lightweight, transparent shielding applications in medical and nuclear environments.

1 January 2021 in Radiation Measurements
Verified
Journal Article
Closed access
ASAkbar Abdi Saray
Akbar Abdi Saray
PKParvin Kaviani
Parvin Kaviani
Daryoush Shahbazi-GahroueiDaryoush Shahbazi-Gahrouei
Daryoush Shahbazi-Gahrouei

12 June 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
FIFarzad Isazadeh
Farzad Isazadeh
ASAkbar Abdi Saray
Akbar Abdi Saray
Regarding to their unique physical and mechanical features, glasses and glass–ceramics are suitable materials for shielding purposes. The present study evaluates the shielding properties of the CaF2–CaO–B2O3–P2O5–SrO–Ta2O5 glass system using Monte Carlo GEANT4 and MCNPX codes for X-ray radiations with an energy range of 20 to 100 keV. MAC values of the Ta0, Ta1, Ta2, Ta2.5, and Ta3 samples of the CaF2–CaO–B2O3–P2O5–SrO–Ta2O5 glass were computed using Phy-X/PSD, GEANT4, and MCNPX codes and compared. According to the results, the programs have good compatibility with each other. For instance, in the energy of 40 keV and for the Ta2 sample, GEANT4 and MCNP codes are 1.445765406 and 1.517801204 cm2/g, respectively, indicating 7.419529525 and 2.829628418% differences with 1.562 cm2/g obtained using the Phy-X/PSD software. According to recent estimations, the Ta3 sample of the CaF2–CaO–B2O3–P2O5–SrO–Ta2O5 glass system can be selected as the best shield compared with the other samples.