Matteo Felipe de Leon

Mr. Matteo Felipe de Leon

Kinesiology, Northern Illinois University, DeKalb, Illinois, USA

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 February 2025 in Sports
Verified
Journal Article
Open access
PDF file
Matteo Felipe de LeonMatteo Felipe de Leon
Matteo Felipe de Leon
Clayton L. Camic, Ph.D.Clayton L. Camic, Ph.D.
Clayton L. Camic, Ph.D.
MHMatthew J. Herring
Matthew J. Herring
CHChris Hill
Chris Hill
The purpose of this study was to determine the accuracy and inter-device reliability of the OTBeat BurnTM heart rate monitor during an incremental test to exhaustion on a cycle ergometer. Twenty males (mean ± SD age = 21.1 ± 1.9 years) volunteered to complete a test to exhaustion on a cycle ergometer with OTBeat BurnTM devices placed on the forearm and upper arm, with a 12-lead electrocardiogram used as the criterion. The heart rate was recorded every 30 s and averaged across each two-minute stage. Accuracy was assessed through calculation of the mean absolute percent error (MAPE), Bland–Altman plot, and Lin’s concordance correlation coefficient (CCC). An intraclass correlation coefficient (ICC) was used to assess the inter-device reliability. Statistical significance was set at α < 0.05. The MAPE (±SD), Bland–Altman regression analyses, and Lin’s CCC values were 0.9 (±0.6)% and 0.8 (±0.5)%, r = 0.107 and 0.303, and rc = 0.998 and 0.998 for the forearm and the upper arm monitors, respectively. The ICC for inter-device reliability was R = 0.999. Our findings indicated the OTBeat BurnTM monitors placed on the forearm and upper arm provided highly accurate and reliable values when compared to an electrocardiogram from low to maximal exercise intensities.

27 January 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
Matteo Felipe de LeonMatteo Felipe de Leon
Matteo Felipe de Leon
Clayton L. Camic, Ph.D.Clayton L. Camic, Ph.D.
Clayton L. Camic, Ph.D.
RKRachel Kowal
Rachel Kowal
BABrittney Aldape
Brittney Aldape
BLBrendan Lochbaum
Brendan Lochbaum
BMBrandon Male
Brandon Male
The purpose of this study was to examine the validity of a Garmin device for estimating heart rate, energy expenditure, and step count during incremental treadmill exercise. Eighteen physically active males (n = 12; mean ± SD age = 22.8 ± 4.7 years; body mass = 83.8 ± 13.4 kg) and females (n = 6; 24.2 ± 5.6 years; 65.2 ± 9.6 kg) completed an incremental treadmill test with the Garmin Vivoactive 4 and criterion methods measuring heart rate, energy expenditure, and step count. Mean absolute percent error (MAPE) and Bland–Altman plots were used to assess accuracy. Acceptable accuracy was defined as MAPE < 5% for heart rate and <10% for energy expenditure and step count. MAPE (±SD) values were 13.0 (±10.1), 19.1 (±15.0), and 4.6 (±5.3)% for heart rate, energy expenditure, and step count, respectively. The Bland–Altman regression analyses illustrated proportional bias was present for heart rate (r = 0.591, p < 0.001) and step count (r = 0.516, p = 0.028), but not energy expenditure (r = 0.351, p = 0.153). These findings indicated that the Garmin Vivoactive 4 provided acceptable accuracy for step count but unacceptable accuracy for heart rate and energy expenditure during incremental treadmill exercise.

6 January 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
Matteo Felipe de LeonMatteo Felipe de Leon
Matteo Felipe de Leon
Clayton L. Camic, Ph.D.Clayton L. Camic, Ph.D.
Clayton L. Camic, Ph.D.
RKRachel Kowal
Rachel Kowal
BABrittney Aldape
Brittney Aldape
BLBrendan Lochbaum
Brendan Lochbaum
BMBrandon Male
Brandon Male
The purpose of this study was to examine the validity of a Garmin wrist-based device for estimating heart rate, energy expenditure, and step count during incremental treadmill exercise in college-aged individuals. Eighteen males and females (mean ± SD age = 23.2 ± 4.9 years) volunteered to complete an incremental treadmill test with the Garmin Vivoactive 4 device and criterion methods (electrocardiogram, indirect calorimetry, and video recording) measuring heart rate, energy expenditure, and step count. Mean absolute percent error (MAPE), simple linear regression, and Bland-Altman plots were used to assess accuracy. Acceptable accuracy was defined as MAPE < 5% for heart rate and < 10% for energy expenditure and step count. Statistical significance was set at α < 0.05. The MAPE (±SD) values were 13.0 (±10.1), 19.1 (±15.0), and 4.6 (±5.3)% for heart rate, energy expenditure, and step count, respectively. The Bland-Altman regression analyses illustrated proportional bias was present for estimations of heart rate (r = 0.591, p < 0.001) and step count (r = 0.516, p = 0.028), but not energy expenditure (r = 0.351, p = 0.153). These findings indicated that the Garmin Vivoactive 4 provided acceptable accuracy metrics for step count, but not heart rate or energy expenditure.

25 December 2024 in Preprints.org
Verified
Preprint
Open access
PDF file
Matteo Felipe de LeonMatteo Felipe de Leon
Matteo Felipe de Leon
Clayton L. Camic, Ph.D.Clayton L. Camic, Ph.D.
Clayton L. Camic, Ph.D.
MHMatthew J. Herring
Matthew J. Herring
CHChris Hill
Chris Hill
The purpose of this study was to determine the accuracy and reliability of the OTBeat Burn heart rate monitor during an incremental test to exhaustion on a cycle ergometer. Twenty males (mean ± SD age = 21.1 ± 1.9 years) volunteered to complete a test to exhaustion on a cycle ergometer with OTBeat Burn devices placed on the forearm and upper arm with a 12-lead electrocardiogram used as the criterion. Heart rate was recorded every 30 seconds and averaged across each two-minute stage. Accuracy was assessed through calculation of mean absolute percent error (MAPE), Bland-Altman plot, and Lin’s Concordance Correlation Coefficient (CCC). An intraclass correlation coefficient (ICC) was used to assess inter-device reliability. Statistical significance was set at αt 0.05. The MAPE (± SD), Bland-Altman regression analyses, and Lin’s CCC values were 0.9 (± 0.6)% and 0.8 (± 0.5)%, r = 0.107 and 0.303, rc = 0.998 and 0.998 for the forearm and the upper arm monitors, respectively. The ICC for inter-device reliability was R = 0.999. Our findings indicated the OTBeat Burn monitors placed on the forearm and upper arm provided highly accurate and reliable values when compared to an electrocardiogram from low to maximal exercise intensities.

11 November 2025 in Sports
Verified
Journal Article
Open access
PDF file
BCBenjamin R. Connors
Benjamin R. Connors
Clayton L. Camic, Ph.D.Clayton L. Camic, Ph.D.
Clayton L. Camic, Ph.D.
AJAndrew - Jagim
Andrew - Jagim
CHChris Hill
Chris Hill
ESEmerson Sebastiao
Emerson Sebastiao
Matteo Felipe de LeonMatteo Felipe de Leon
Matteo Felipe de Leon
The primary purpose of this study was to examine the acute effects of a multi-ingredient preworkout supplement (MIPS) on isometric, concentric, and eccentric peak torque and electromyographic (EMG) responses of the leg extensors during a fatiguing isokinetic protocol. Thirteen male subjects (mean age ± SD = 22.9 ± 2.2 years) were assigned in crossover fashion to ingest an MIPS or placebo before an isokinetic protocol that consisted of 30 maximal, concentric and eccentric muscle actions with EMG signals recorded from the vastus lateralis, rectus femoris, and vastus medialis muscles. Immediately before (PRE) and after (POST) the isokinetic fatigue protocol, subjects were assessed for isometric peak torque. The MIPS condition resulted in greater isometric (205 ± 48 vs. 185 ± 44 N·m, p = 0.04) and concentric (121 ± 34 vs. 103 ± 27 N·m, p = 0.015) torque values versus placebo (collapsed across time). For eccentric peak torque as well as EMG amplitude and frequency values, there were no significant (p > 0.05) interactions or main effects for each condition. These findings indicated that acute ingestion of the MIPS enhanced isometric and concentric peak torque of the leg extensors, which was not explained by changes in the EMG signal.