Objectives: To evaluate the applicability and utility of point-of-care lung ultrasonography (POCLUS) for the diagnosis of community-acquired pneumonia (CAP) in a pediatric emergency department. Methods: A prospective observational study on children with suspected CAP was carried out in a pediatric emergency department from August to December 2014. The evaluation of the chest radiography (CR) by two independent radiologists was considered as a reference standard. POCLUS was performed by pediatricians who were blinded to CR results. Following the WHO criteria, typical CAP was defined as an alveolar consolidation or infiltrate in CR and a visualization of lung consolidation with sonographic air bronchograms in POCLUS. The diagnostic accuracy of POCLUS (sensitivity, specificity, positive, and negative predictive values) was established using CR as a gold standard. Results: We enrolled 200 children with a median age of 29.5 months (interquartile range, 18.5–52.5); 58.1% were males and 42.0% had focal decreased breath sounds and/or crackles. The prevalence of typical CAP according to the radiologist’s evaluation was 42.5% (end-point consolidation and/or pleural effusion 56.5%, alveolar infiltrate 43.5%). The sensitivity and specificity of POCLUS were 87.1% [95% confidence interval (CI) 78.0–93.4] and 94.8% (95% CI 89.0–98.1), respectively. The positive and negative predictive values were 92.5% (95% CI 84.4–97.2) and 90.8% (95% CI 84.2–95.3), respectively. Conclusion: POCLUS performed by an emergency pediatrician with a limited experience in ultrasonography enables the diagnosis of pneumonia with high accuracy. POCLUS could become a feasible and promising alternative to CR in the diagnosis of suspected CAP, leading to a relevant decrease in children’s exposure to ionizing radiations. Further studies specifically carried out in the pediatric outpatient setting are needed.
1 April 2019 in European Journal of Emergency Medicine
Objective: The aim of this study is to evaluate the utility of Point-Of-Care Ultrasound (POCUS) for diagnosing distal forearm fractures in pediatric emergency departments (ED). Patients and methods: A prospective observational study was carried out in children aged younger than 15 years attended in an ED with an indication of radiography because of a suspected distal forearm fracture. The POCUS was performed considering cortical irregularity or disruption compatible with fracture. Then, the radiography was requested and the patient was evaluated by an ED traumatologist. Both tests were blinded to each other. The radiograph was considered to be the reference diagnostic test. Diagnostic validation tests were performed. Results: A total of 115 patients [mean age: 9.1 (SD: 3.1) years; 50.4% males] were included, with 57 of these presenting fractures: 42 (73.7%) single bone fractures and 15 (26.3%) combined fractures of the radius and ulna. As such, 72 fractures were detected (prevalence 31.3%). The sensitivity and specificity of POCUS for detecting fractures were 94.4% [95% confidence interval (CI): 86.4–98.5] and 96.8% (95% CI: 92.8–99.0), respectively. The positive and negative predictive values were 93.2% (95% CI: 84.7–97.7) and 97.5% (95% CI: 93.6–99.3), respectively. Conclusion: POCUS enables the clinical diagnosis of distal forearm fractures in ED. In addition, this is a highly accurate technique that can be applied easily by the ED pediatrician. As such, its inclusion as part of the physical examination could improve the accuracy of the clinical diagnosis and the global management of the patient.
We wished to replicate evidence that an experimental paradigm of speech illusions is associated with psychotic experiences. Fifty-four patients with a first episode of psychosis (FEP) and 150 healthy subjects were examined in an experimental paradigm assessing the presence of speech illusion in neutral white noise. Socio-demographic, cognitive function and family history data were collected. The Positive and Negative Syndrome Scale (PANSS) was administered in the patient group and the Structured Interview for Schizotypy-Revised (SIS-R), and the Community Assessment of Psychic Experiences (CAPE) in the control group. Patients had a much higher rate of speech illusions (33.3% versus 8.7%, ORadjusted: 5.1, 95% CI: 2.3–11.5), which was only partly explained by differences in IQ (ORadjusted: 3.4, 95% CI: 1.4–8.3). Differences were particularly marked for signals in random noise that were perceived as affectively salient (ORadjusted: 9.7, 95% CI: 1.8–53.9). Speech illusion tended to be associated with positive symptoms in patients (ORadjusted: 3.3, 95% CI: 0.9–11.6), particularly affectively salient illusions (ORadjusted: 8.3, 95% CI: 0.7–100.3). In controls, speech illusions were not associated with positive schizotypy (ORadjusted: 1.1, 95% CI: 0.3–3.4) or self-reported psychotic experiences (ORadjusted: 1.4, 95% CI: 0.4–4.6). Experimental paradigms indexing the tendency to detect affectively salient signals in noise may be used to identify liability to psychosis.
To describe the outcomes of the pilot program of a rapid HIV antibody screening test offered at Basque pharmacies, the socio-demographic characteristics of users and their acceptance of the test. Users of a rapid HIV antibody screening test (20 pharmacies) were surveyed. A random sample of 3514 tests (N = 806) performed in 1 year was taken. Statistical analyses included exact tests. There were 806 valid questionnaires. Seven tests were positive (0.85%; 95% confidence interval: 0.34-1.75); five of the users with positive tests were men. The mean age was 36.2 years (standard deviation = 11.0; range: 16-82 years; 70.7% men). Users' risk behavior was predominantly heterosexual and half of the users (58.6%) had no previous HIV tests. The main reasons for choosing this test were its speed, and the convenience and accessibility of community pharmacies. This new rapid HIV antibody screening test in community pharmacies could supplement other HIV screening programs currently in operation.