The objective of this study is to identify essential aspects influencing radiation dose in computed tomography [CT] of the chest, abdomen and pelvis by intraindividual comparison of imaging parameters and patient related factors. All patients receiving at least two consecutive CT examinations for tumor staging or follow-up within a period of 22 months were included in this retrospective study. Different CT dose estimates (computed tomography dose index [CTDIvol], dose length product [DLP], size-specific dose estimate [SSDE]) were correlated with patient’s body mass index [BMI], scan length and technical parameters (tube current, tube voltage, pitch, noise level, level of iterative reconstruction). Repeated-measures-analysis was initiated with focus on response variables (CTDIvol, DLP, SSDE) and possible factors (age, BMI, noise, scan length, peak kilovoltage [kVp], tube current, pitch, adaptive statistical iterative reconstruction [ASIR]). A univariate-linear-mixed-model with repeated-measures-analysis followed by Bonferroni adjustments was used to find associations between CT imaging parameters, BMI and dose estimates followed by a subsequent multivariate-mixed-model with repeated-measures-analysis with Bonferroni adjustments for significant parameters. A p-value <0.05 was considered statistically significant. We found all dose estimates in all imaging regions were substantially affected by tube current. The iterative reconstruction significantly influenced all dose estimates in the thoracoabdominopelvic scans as well as DLP and SSDE in chest-CT. Pitch factor affected all dose parameters in the thoracoabdominopelvic CT group. These results provide further evidence that tube current has a pivotal role and potential in radiation dose management. The use of iterative reconstruction algorithms can substantially decrease radiation dose especially in thoracoabdominopelvic and chest-CT-scans. Pitch factor should be kept at a level of ≥1.0 in order to reduce radiation dose.
Purpose To assess digital patient briefing as an alternative to conventional paper documentation. Materials and Methods 502 patients with a planned computed tomography (CT) examination were selected for digital patient briefing using the E-ConsentPro software from Thieme Compliance on an iPad by Apple (Cupertino, California, USA). For the analysis, three age groups were formed. The time required for the patient briefing, the number of open questions as well as the time needed for discussion with physicians were determined. Student’s t-test was performed to assess statistical significance. Results There was no significant difference between patient age and briefing time which was about 20 minutes on average. The number of open or unclear questions increased with patient age. While patients younger than 30 years of age had about 2 open questions, patients over 30 and 60 years had about 4 and 5 questions, respectively. The total time needed for discussion with physicians was less than 2 minutes on average. A significant difference in the time required for discussion with physicians could not be observed between the individual age groups. Conclusion Tablet-based digital briefing allows the storage of patient documents with reasonable time and effort. Furthermore, it minimizes the risk of data loss. Key Points Citation Format
26 July 2023 in Journal of Radiological Protection
To evaluate the image quality (IQ) of advanced modeled iterative reconstruction (ADMIRE; Siemens Healthcare, Forchheim, Germany) applying image texture and image visual impression as a supplement to physical parameters such as noise level and spatial resolution. An ACR-phantom with four modules was examined at different radiation dose levels. To characterise the image texture, two Haralick texture parameters, contrast and entropy, were assessed at different dose levels and reconstruction algorithms. The visual impression of images and the low-contrast detectability were evaluated by the structural similarity index (SSIM). The spatial resolution was determined by the modulation transfer functions and the line spread function. The Haralick texture parameters, contrast and entropy, decreased with increasing ADMIRE levels. ADMIRE III, IV and V offered a comparable contrast and entropy to those calculated by filtered back projection (FBP) with a radiation dose reduction up to 50%. SSIM (low-contrast detectability) improved with increasing ADMIRE levels. SSIM calculated by ADMIRE IV and V revealed comparable IQ to FBP with a decreased CTDIvol up to 50%. Spatial resolution was retained up to 90% dose reduction. Compared to FBP at the same dose level, the image noise decreased up to 61% with higher ADMIRE levels (σFBP = 17.3 HU and σADMIRE V = 10.6 HU at 6.65 mGy). Taking texture analysis and visual perception into account, a more realistic assessment of the dose reduction potential of ADMIRE can be achieved than quality metrics based alone on physical measurements.
3 September 2020 in RöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren