Low temperature thermal desalination (LTTD) process involves flash evaporation of a seawater at 28–29°C in a single-stage evaporator maintained at a vacuum of around 25–27 m bar (abs). The seawater was splashed inside an evaporator through a 0.1 m diameter upward facing nozzles of around 24 nos arranged evenly throughout the evaporator and generated vapour was condensed in the shell and tube condenser using cooling water available at 12–13°C sucked from the deep sea through a long HDPE pipe. The main objective of this study was to find out the effect of geometry of the upward facing nozzles on the flash evaporation rate as well as on the non-equilibrium temperature difference (NETD) of the flashing process. Two different spout nozzle geometries with 0.37–0.87 m height were used in the experiment. The study indicated that the flashing rate increased by 0.9% (average) and and the NETD (Two – Tsat) decreased by 0.7°C (average), respectively, when nozzle height was increased by 0.87 m. Mechanism that controlled these two factors were identified and discussed in this paper. Drawbacks of 0.37 m nozzle geometry was also discussed. It was reported in literature that 4% yield ratio was obtained for a nozzle injection pressure of 1 bar for a similar desalination process. But in the present study, a maximum of 1.12% yield ratio was obtained with a nozzle injection pressure of around 0.17 bar. In this work,the effect of the process parameters on the liquid flashing in a LTTD desalination process was investigated and discussed. In order to fine tune the evaporator design for the future LTTD plants, the experimental results of flash evaporation were compared with two mathematical models obtained from the literature. While comparing the results, it was observed that the model which used actual heat (Twi – Two) made a good agreement with the experimental data compared to the other model that used superheat (Twi – Tsat). From the experimental study, it was observed that the NETD (i.e. thermal loss) measured was found to be higher than the predicted value. The reason that caused the difference in the NETD value was investigated and discussed. Suitable suggestions to reduce these NETD in the flashing process were also presented.
The objective of this paper is to present a methodology to predict vacuum load theoretically and to compare those results with the experimental values for validation especially the non-condensable gas load and escape water vapour load. The primary objective of this paper is to find out the accumulated effect of non-condensable gases on the vacuum load of low-temperature thermal desalination (LTTD) plant. Suggestions to control the NC gas and escape vapour load on the LTTD process were also discussed in this paper. Determination of an exact amount of vacuum load for the plant is significant, since vacuum system alone shares about 31% of total energy demand of the LTTD plant. Load contribution given by the gas mixtures such as escape water vapour, non-condensable gas and air leak in to the system was experimentally measured by conducting suitable experiments in a running plant of 100 m3/d capacity located in the Island of Agatti, UT Lakshadweep group of Islands, India. Study at Kavaratti plant of same capacity showed that the escape vapour rate was equivalent to 0.3% of the freshwater generation rate of the plant, which was used as an input value for Agatti vacuum load calculation for escape vapour rate. On comparison of the experimental results of non-condensable gas release rate of Agatti plant with the published data and predicted values using methodology, an agreement up to 16 and 7.7% was obtained, respectively, under the same operating conditions. Also, an agreement up to 15% was obtained between the experimental results of Agatti plant with that of observed results of Kavaratti for water vapour escape rate from the main process condenser. It was reported in the literature that for MED desalination system, the extraction of vapour from the evaporator unit linked with a removal of 10–20 units of vapour corresponded to every unit mass of NC gases. But in the present study, for the LTTD process, it was measured that the accumulated effect of NC gases for every unit mass resulted in extraction of 1.6 unit mass of vapour (approx) from the process condenser. This low value could be due to low operating temperature range of LTTD process and use of low-temperature deep-sea cooling water from the ocean in the condenser tubes. From calculation, it was noticed that decrease in molecular weight of gas increased the volumetric vacuum load for the same operating conditions and gas mass flow rates. Also, it was observed that the parameters such as operating pressure, duct loss, mass flow rate of feed water influence the total vacuum load of LTTD plant.
29 August 2020 in International Journal of Green Energy
This paper discusses about the effect of feeder height and heat flux on the heat transfer characteristics of horizontal tube falling film evaporation in the thermal regimes. In order to investigate this, a two- dimensional CFD model was developed to perform simulation and results were compared and validated with published data available in the literature. Heat transfer co-efficients in the thermal regimes were determined from the CFD simulation and the results were recorded, analyzed and validated with the mathematical models available in the literature. The novelty of the current study is to predict the commencement of the fully developed thermal region over the tube from the simulation model under varying feeder height and heat flux. An effort was also made to measure the liquid film thickness around the tube from the CFD model in the thermal regimes. It is observed that angle of thermally developing region contracts and fully developed thermal region extends with the increase of the feeder height and heat flux. It is observed from the study that increase of heat flux by 10 kW/m2 resulted in increase of heat transfer co-efficient value by 10–12% average in thermally developing region and 12–15% average in fully developed region. Thinnest liquid film thickness observed between 85 and 127°angle. Shifting of thinnest region of liquid film upward from the mid tube with the increase of the feeder height and heat flux is noted.
27 November 2015 in Desalination and Water Treatment
Low-temperature thermal desalination is a process which involves evaporation of warm surface sea water at 28–29°C inside an evaporator which is maintained at a subatmospheric pressure of around 24–27 mbar [abs] and the resultant vapour is condensed in the condenser using deep-sea cooling water (12–13°C) drawn from a depth of around 350–400 m (approx). Designed heat load and overall heat transfer co-efficient of the condenser are around 3.4 MW and 1,790 W/m2 K, respectively, for an inside tube cooling water velocity of 1.25 m/s. The primary objective of this paper is to experimentally study the performance of a shell and tube condenser and to compare it with the HTRI 6.0 results as well as Kern method for the same operating parameters. A comparative study showed that the predicted results of HTRI were in good agreement with experimental values as well as with Kern method. After the comparative study, the reasons for variation in results were identified, reviewed and discussed. Experimental study revealed that the deviation of actual inlet conditions from the design conditions at the plant site greatly influences the condenser performance. It was observed from data analysis that the effect of fouling of deep-sea cooling water on the condenser performance is insignificant. Uncertainty analysis also has been carried out and presented in this paper.
1 January 2021 in Desalination and Water Treatment